www.factorybuysdirect.com
200316-01A
20
TO TURN OFF GAS TO APPLIANCE
Shutting Off Heater
Turn control knob clockwise
to the
OFF position.
Shutting Off Burner Only
(pilot stays lit)
Turn control knob clockwise
to the
PILOT position.
MANUAL LIGHTING PROCEDURE
1. Remove front panel.
2. Follow steps 2 through 5 under
Lighting
Instructions
, page 18.
3. With control knob pressed in, strike match.
Hold match to pilot until pilot lights.
OPERATION
THERMOSTAT CONTROL OPERATION
The thermostatic control used on this model
differs from standard thermostats. Standard
thermostats simply turn the burner on and off.
The thermostat used on this heater senses the
room temperature. At times the room may ex-
ceed the set temperature. If so, the burner will
shut off. The burner will cycle back on when
room temperature drops below the set tem-
perature. The control knob can be set to any
comfort level between HIGH (5) and LOW (1).
4. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Follow step 8 under
Lighting Instructions
, page 19.
5. Replace front panel.