FILLING THE HOPPERS:
Remove hoppers, fill with product, and replace. Hoppers hold 4 to 6
IDS
depending on product density
NOTE:
Hoppers are equipped with product chutes, which have sliding, no spill, closures
These are designed to prevent spillage when filling and removing hoppers.
PRODUCT STRENGTH ADJUSTMENT:
Water flow rate is factory set at 0.75 oz per second.
Product throw is factory set on speed dial to No. 6 (4-5 grams / sec).
These settings are the equivalent of 1.5 Ibs. (681 grams) of product per 1 gallon of water. The
dispense duration for this volume will be approximately 2.8 minutes.
FILLING BOWLS AUTOMATICALLY:
1. Position full hopper into the machine compartment, making sure the auger drives are fully
engaged.
2. Position product chutes to point down into the mixing chambers.
3. Push in the no-spill closures on the product chutes.
4. Activate power switch.
5. With door open push in the door safety switch and hold for 20 seconds. The auto fill system will
start filling.
6. Release the door safety switch and close door, allow auto fill system to complete filling.
7. Activate the controls on the Ugolini MT2UL to begin cooling.
NOTE:
After the bowls are filled, remove and refill hoppers
4