background image

A.   TO ADJUST PRODUCT THROW (ILL # 4) 

1.      Open Door Assembly and remove Steam Deflector 
         by pulling  it forward. 
2.      To make adjustment use a screwdriver with 1/2 inch  
         wide blade.  Engage product adjuster as shown below  
         and turn as follow. 
3.      Turn clockwise to increase drink strength or 
         counter-clockwise to reduce it.  
         Check drink strength after every half a turn.  
         If after maximum adjustment, drink taste is not as  
         desired proceed to adjust the water flow according to                         

 

 

        procedure B below.                                                                             

 

4.      Re-install Steam Deflector. 
 
 

B.   TO ADJUST WATER FLOW RATE (ILL. # 5)                     

 

1.      Remove right hand side cover of the unit. 
         (looking at the unit from the front) 
2.      Locate Flow Adjustment Key inside unit mounted 
          above water valve. 
3.      Engage Flow Adjustment Key into Flow Controller 
         and rotate counterclockwise to decrease 
         and clockwise to increase drink strength.  
         When making strength adjustments, do not turn 
         Adjustment Key more than 1/8” at a time without  
         checking drink strength. 
4.      Return Adjustment Key back into keyholder. 
         If after maximum adjustment, drink taste is still not                
         strong as desired,  take auger spring  out of the hopper  and  re-

move the product adjuster.                                               

 

                

                               

C.     DRINK SIZE ADJUSTMENT (ILL. # 6) 

          

(AUTOMATIC UNITS - WITH TIMER)

 

1.      Remove right side panel. 
2.      Turn knob on Timer right to increase or left to decrease   drink size.  

The number 6 on the Timer indicates   approximate drink size at a 
factory setting of  1 oz./sec. flow rate. 

3.      Press push button and check drink size.  Repeat if  
         necessary, until desired drink size is dispensed. 
4.      Replace the side panel.

                                                                         

        

 

Illustration No. 5 – Water  Inlet Valve

 

Illustration No. 4 – Product

 adjuster

 

Illustration No 6  - Timer

 

DRINK STRENGTH ADJUSTMENTS  

NOTE: The unit has been factory preset to deliver water at 1 oz. per second 

Summary of Contents for ICAP 1 B LD

Page 1: ...ng Island City NY 11105 718 932 1414 FAX 718 932 7860 THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE APPLICABLE FEDERAL STATE OR LOCAL PLUMBING CODES HAVING JURISDICTION IN ADDITION 1 A QUICK DI...

Page 2: ...re WATER PRESSURE REQUIRED 30 120 psi 2 1 8 6 kg cm2 ELECTRICAL Voltage 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V Frequency 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 H...

Page 3: ...4 minutes to fill the tank 6 Fill hopper with DRY powdered cocoa mix or cappuccino product See filling instructions 7 Turn heater switch on and allow 10 to 15 minutes for water to heat 8 Push on Disp...

Page 4: ...he valve Caution Do not plug into power outlet yet Make sure the Heater Switch is OFF Toggle Down II PRIMING MANUAL BOTTLE POUROVER Toggle UP Water Selection Switch on the back panel 1 Do NOT plug int...

Page 5: ...will dispense water at the rate of 1 oz per second Repeat it several times to check for con sistent output 2 While the tank is heating up remove the hopper load with product and reposition it back in...

Page 6: ...unterclockwise to decrease and clockwise to increase drink strength When making strength adjustments do not turn Adjustment Key more than 1 8 at a time without checking drink strength 4 Return Adjustm...

Page 7: ...emove Mixing Chamber by turning Counterclockwise and pulling forward A Remove Mixing Chamber Insert by pulling up B Remove Mixing Chamber Extension by pulling down 4 Remove Mixer Blade by pulling forw...

Page 8: ...just product throw see To Adjust Product Rate Water drips from mixing chamber a Temperature too high b Leaking inlet water valve c Too much water in tank s a Adjust the thermostat accordingly b Check...

Page 9: ...9 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD with lit door WHIPPER B without lit door Illustration No 8...

Page 10: ...ORT PLATE F AUGER MOTOR 90209 17 HOSE BARB FITTING K435C 52 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 ADJ VALVE ASSY H5107 NPT K415A 53 O RING 20015 19 HOSE NUT 95101 54 CARTRIDGE HEATER 20W 87024...

Page 11: ...11 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD POUROVER with lit door Illustration No 9...

Page 12: ...AUGER MOTOR 115V 52037 16 HOSE NUT 95101 53 O RING 20015 17 WATER VALVE INLET ASS Y L477A 54 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 HEATER SWITCH L299A 55 SUPPORT PLATE F AUGER MOTOR 90209 19 AU...

Page 13: ...13 Illustration No 10 ICAP MINI B LD w Lit Door and MINI WHIPPER B w o Lit Door DESCRIPTION AND LOCATION OF COMPONENTS...

Page 14: ...OVER RC42A 49 SUPPORT PLATE F AUGER MOTOR 90209 16 HOSE BARB FITTING K435A 50 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 17 ADJ VALVE ASSY H5107 NPT K415A 51 O RING 20015 18 HOSE NUT 95101 52 CARTRIDGE...

Page 15: ...15 AUTOMATIC ICAP 1 B LD LIT DOOR WHIPPER B NO LIT DOOR AUTOMATIC ICAP 1 MINI B LD LIT DOOR MINI WHIPPER B NO LIT DOOR...

Page 16: ...16 MANUAL ICAP 1 B LD LIT DOOR MANUAL ICAP 1 MINI B LD LIT DOOR...

Page 17: ...TIMER TERMINAL NO CONNECT ORANGE WIRES TO TIMER TERMINAL N NOTE TO CONVERT TO TIMER CONTROLLED DISPENSE CONNECT BLUE WIRE TO TIMER TERMINAL L1 USE PIGGY BACK TERMINAL PROVIDED DOOR UNIT INDICATOR LIGH...

Page 18: ...18...