START UP INSTRUCTIONS FOR  ICAP1 POUROVER CAPPUCCINO DISPENSER – see ill. 3 

 

I.   INSTALLATION INSTRUCTIONS

 

This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction.   
In addition: 
1.        A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the machine 

can be moved for cleaning underneath. 

2.        An approved back flow prevention device, such as a double check valve to be installed between the machine and the wa-

ter supply. 

The ICAP1 POUROVER beverage dispenser is equipped with a 3/4” Water Inlet Valve (¼"  to 3/4” adapter supplied with the 
unit) which is located on the right side in the back of the base (when looking at the machine from the front). 
HIGHLY RECOMMENDED:   A WATER SHUT-OFF VALVE and A WATER FILTER, preferably a combination Charcoal/Phosphate 
Filter, to remove odors and inhibit lime and scale build up in the machine.  
Note:  In areas with extremely hard water, a water softener must be installed in order to prevent a malfunctioning of the equip-
ment and in order not to void the warranty.  
After the machine has been unpacked and placed on a counter, pull out the drip tray and splash guard. 
It should contain the following:    A Set of  4 Adjustable Leveling Legs & Water Inlet Fitting. 
 
Connect the 

¼" dia.

  copper waterline to the 

¼" flare

 water inlet fitting of the valve. 

Caution:    Do not plug into power outlet yet.  Make sure the Heater Switch is  OFF  (Toggle Down).  
 

II.   PRIMING -  MANUAL/BOTTLE  POUROVER 

 

(Toggle UP, Water Selection Switch, on the back panel) 

1.  Do NOT plug into power outlet yet.

 

2.  Make sure Heater Switch  is in the OFF position, located in back of machine. 
3.  Fill reservoir tank (top) with 2 gallons of water, wait about 3 minutes for water to fill Heating Tank below.   
     Refill Top Reservoir Tank with another 2 gallons of water.  The unit will NOT dispense unless the Top Reservoir Tank is at 

least 1/2 full. 

  So keep Reservoir Tank full

.  

Note:  The unit has a  Float (item 3, Ill. 8) inside the Reservoir Tank, which stops the  machine from dispensing 
when the Reservoir Tank is low. 

4.  Plug into power outlet. 
5.  Turn  Heater Switch  ON. 
6.  Allow  10 to 15 minutes for water to reach dispense temperature of 190°F. Heater Indicator Light (red) goes ON when 

heater is on   (see  lower front panel). 

7.  Fill hopper with product. 
8.  Place cup under dispenser. 
9.  Push and hold Dispense Button (green) until water flows from mixing chamber. 
10.  Machine is primed and ready to go. 

           

III.   PRIMING INSTRUCTIONS FOR  ICAP1 POUROVER 

PRIMING - AUTOFILL   

(Toggle Down,Water Selection Switch, on the back panel) 

1.  Plug into power outlet. 
2.  Turn  Heater Switch  ON. 
3.  Allow  10 to 15 minutes for water to reach dispense temperature of 190°F.  
     Heater Indicator Light (red) goes ON when  heater is on  (see  lower front panel). 
4.  Fill hopper with product. 
5.  Place cup under dispenser. 
6.  Push and hold Dispense Button (green) until water flow s from mixing chamber 
7.  Machine is primed and ready to go.

 

Summary of Contents for ICAP 1 B LD

Page 1: ...ng Island City NY 11105 718 932 1414 FAX 718 932 7860 THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE APPLICABLE FEDERAL STATE OR LOCAL PLUMBING CODES HAVING JURISDICTION IN ADDITION 1 A QUICK DI...

Page 2: ...re WATER PRESSURE REQUIRED 30 120 psi 2 1 8 6 kg cm2 ELECTRICAL Voltage 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V Frequency 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 H...

Page 3: ...4 minutes to fill the tank 6 Fill hopper with DRY powdered cocoa mix or cappuccino product See filling instructions 7 Turn heater switch on and allow 10 to 15 minutes for water to heat 8 Push on Disp...

Page 4: ...he valve Caution Do not plug into power outlet yet Make sure the Heater Switch is OFF Toggle Down II PRIMING MANUAL BOTTLE POUROVER Toggle UP Water Selection Switch on the back panel 1 Do NOT plug int...

Page 5: ...will dispense water at the rate of 1 oz per second Repeat it several times to check for con sistent output 2 While the tank is heating up remove the hopper load with product and reposition it back in...

Page 6: ...unterclockwise to decrease and clockwise to increase drink strength When making strength adjustments do not turn Adjustment Key more than 1 8 at a time without checking drink strength 4 Return Adjustm...

Page 7: ...emove Mixing Chamber by turning Counterclockwise and pulling forward A Remove Mixing Chamber Insert by pulling up B Remove Mixing Chamber Extension by pulling down 4 Remove Mixer Blade by pulling forw...

Page 8: ...just product throw see To Adjust Product Rate Water drips from mixing chamber a Temperature too high b Leaking inlet water valve c Too much water in tank s a Adjust the thermostat accordingly b Check...

Page 9: ...9 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD with lit door WHIPPER B without lit door Illustration No 8...

Page 10: ...ORT PLATE F AUGER MOTOR 90209 17 HOSE BARB FITTING K435C 52 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 ADJ VALVE ASSY H5107 NPT K415A 53 O RING 20015 19 HOSE NUT 95101 54 CARTRIDGE HEATER 20W 87024...

Page 11: ...11 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD POUROVER with lit door Illustration No 9...

Page 12: ...AUGER MOTOR 115V 52037 16 HOSE NUT 95101 53 O RING 20015 17 WATER VALVE INLET ASS Y L477A 54 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 HEATER SWITCH L299A 55 SUPPORT PLATE F AUGER MOTOR 90209 19 AU...

Page 13: ...13 Illustration No 10 ICAP MINI B LD w Lit Door and MINI WHIPPER B w o Lit Door DESCRIPTION AND LOCATION OF COMPONENTS...

Page 14: ...OVER RC42A 49 SUPPORT PLATE F AUGER MOTOR 90209 16 HOSE BARB FITTING K435A 50 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 17 ADJ VALVE ASSY H5107 NPT K415A 51 O RING 20015 18 HOSE NUT 95101 52 CARTRIDGE...

Page 15: ...15 AUTOMATIC ICAP 1 B LD LIT DOOR WHIPPER B NO LIT DOOR AUTOMATIC ICAP 1 MINI B LD LIT DOOR MINI WHIPPER B NO LIT DOOR...

Page 16: ...16 MANUAL ICAP 1 B LD LIT DOOR MANUAL ICAP 1 MINI B LD LIT DOOR...

Page 17: ...TIMER TERMINAL NO CONNECT ORANGE WIRES TO TIMER TERMINAL N NOTE TO CONVERT TO TIMER CONTROLLED DISPENSE CONNECT BLUE WIRE TO TIMER TERMINAL L1 USE PIGGY BACK TERMINAL PROVIDED DOOR UNIT INDICATOR LIGH...

Page 18: ...18...

Reviews: