background image

MODELS: 

ICAP 1 B LD 

WHIPPER B 

ICAP1 B LD 

ICAP B LD 

WHIPPER B 

STORAGE CAPACITY

 

   Hopper Capacity [lb.] 

8  

8  

8  

8  

8  

   Tank Capacity     [gal.] 

1.5 

1.5 

1.5 

0 .6   

0.6 

 

 

 

 

 

 

PRODUCTION CAPACITY

 

  Continuous Draw Rate  [oz/drinks/min.]   
                                       [drinks / hour] 

2 (6 oz.) drinks/min 

120 

2 (6 oz.) . 

120   

2 (6 oz.)  

120  

2 (6 oz.)  

60   

2 (6 oz.)  

60   

  Burst Capacity [oz.], drinks 

28   (6 oz.)  

28   (6 oz.)  

28   (6 oz.)  

12   (6 oz.)  

12   (6 oz.) 

                 

 

BURST CAPACITY 

- Max. number of drinks dispensable with available hot water - based on 6 oz. cup. 

 

FLOW ADJUSTMENT RATE:

  1 oz./sec. 

STRENGTH ADJUSTMENT RANGE:  

22  -  34  gr/(6 oz.) drink  

RECOVERY TIME:  

10 - 18  

drinks [min.] 

DISPENSING RATE:   

[1 oz./sec.] 

 

 

 

 

 

 

DIMENSIONS  & CONNECTIONS

 

     

Height  [inches]: 

 

23+2.5” legs 

23+2.5” legs 

23+2.5” legs 

23+1” feet  

23+1” feet  

     

Width [inches]:

 

     

Depth [inches]: 

 

21 

21 

21 

16 

16 

CABINET MATERIAL:  

Powder Coated Steel                                                                                                                                                    

*Optional 

WATER INLET CONNECTION:  

1/4”  Male Flare 

WATER PRESSURE REQUIRED:  

30 -120 psi  (2.1 - 8.6 kg/cm

 

ELECTRICAL

 

   

Voltage:  

 

110V or 220 V 

110V or 220 V 

110V or 220 V 

110V or 220 V 

110V or 220 V 

   

Frequency:  

 

60 Hz/50Hz 

60 Hz/50Hz 

60 Hz/50Hz 

60 Hz/50Hz 

60 Hz/50Hz 

   

Phase:  

 

Single 

Single 

Single 

Single 

Single 

   

Max. Amps:  

 

15 A @ 115 V 

15 A @ 115 V  15 A @ 115 V 

15 A @ 115 V 

15 A @ 115 V 

   

Heater Wattage  [kw]:

          

 

1.7 

1.7 

1.7 

1.5 

1.5 

SPECIFICATIONS 

FRONT VIEW

MIXING CHAMBER

PRODUCT GUIDE

CLEANING LABEL

POWER CORD TO

FRONT PANEL

SUPPORT LEGS

PRODUCT HOPPER

EXTENSION

TOP COVER

MIXING CHAMBER

STEAM DEFLECTOR

CHAMBER INSERT

(PLACE INSIDE

MIXING CHAMBER)

GRILL

DRIP TRAY

DRIP TRAY HOLDER

RINSE SWITCH

HEATER LIGHT

HEATER SWITCH

ICAP1 B LD [w/lit door]

WHIPPER B [w/o lit door]

CLEANING LABEL

MINI WHIPPER B [w/o lit door]

ICAP MINI B LD [w/lit door]

FRONT VIEW

DRIP TRAY

DRIP TRAY HOLDER

GRILL

EXTENSION

MIXING CHAMBER

MIXING CHAMBER

STEAM DEFLECTOR

PRODUCT GUIDE

HEATER LIGHT

SUPPORT LEGS

POWER CORD TO

FRONT PANEL

RINSE SWITCH

HEATER SWITCH

TOP COVER

PRODUCT HOPPER

Illustration No. 1 

 

Summary of Contents for ICAP 1 B LD

Page 1: ...ng Island City NY 11105 718 932 1414 FAX 718 932 7860 THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE APPLICABLE FEDERAL STATE OR LOCAL PLUMBING CODES HAVING JURISDICTION IN ADDITION 1 A QUICK DI...

Page 2: ...re WATER PRESSURE REQUIRED 30 120 psi 2 1 8 6 kg cm2 ELECTRICAL Voltage 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V 110V or 220 V Frequency 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 Hz 50Hz 60 H...

Page 3: ...4 minutes to fill the tank 6 Fill hopper with DRY powdered cocoa mix or cappuccino product See filling instructions 7 Turn heater switch on and allow 10 to 15 minutes for water to heat 8 Push on Disp...

Page 4: ...he valve Caution Do not plug into power outlet yet Make sure the Heater Switch is OFF Toggle Down II PRIMING MANUAL BOTTLE POUROVER Toggle UP Water Selection Switch on the back panel 1 Do NOT plug int...

Page 5: ...will dispense water at the rate of 1 oz per second Repeat it several times to check for con sistent output 2 While the tank is heating up remove the hopper load with product and reposition it back in...

Page 6: ...unterclockwise to decrease and clockwise to increase drink strength When making strength adjustments do not turn Adjustment Key more than 1 8 at a time without checking drink strength 4 Return Adjustm...

Page 7: ...emove Mixing Chamber by turning Counterclockwise and pulling forward A Remove Mixing Chamber Insert by pulling up B Remove Mixing Chamber Extension by pulling down 4 Remove Mixer Blade by pulling forw...

Page 8: ...just product throw see To Adjust Product Rate Water drips from mixing chamber a Temperature too high b Leaking inlet water valve c Too much water in tank s a Adjust the thermostat accordingly b Check...

Page 9: ...9 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD with lit door WHIPPER B without lit door Illustration No 8...

Page 10: ...ORT PLATE F AUGER MOTOR 90209 17 HOSE BARB FITTING K435C 52 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 ADJ VALVE ASSY H5107 NPT K415A 53 O RING 20015 19 HOSE NUT 95101 54 CARTRIDGE HEATER 20W 87024...

Page 11: ...11 DESCRIPTION AND LOCATION OF COMPONENTS ICAP1 B LD POUROVER with lit door Illustration No 9...

Page 12: ...AUGER MOTOR 115V 52037 16 HOSE NUT 95101 53 O RING 20015 17 WATER VALVE INLET ASS Y L477A 54 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 18 HEATER SWITCH L299A 55 SUPPORT PLATE F AUGER MOTOR 90209 19 AU...

Page 13: ...13 Illustration No 10 ICAP MINI B LD w Lit Door and MINI WHIPPER B w o Lit Door DESCRIPTION AND LOCATION OF COMPONENTS...

Page 14: ...OVER RC42A 49 SUPPORT PLATE F AUGER MOTOR 90209 16 HOSE BARB FITTING K435A 50 GEAR AUGER DRIVE MOTOR GEAR PLASTIC 90208 17 ADJ VALVE ASSY H5107 NPT K415A 51 O RING 20015 18 HOSE NUT 95101 52 CARTRIDGE...

Page 15: ...15 AUTOMATIC ICAP 1 B LD LIT DOOR WHIPPER B NO LIT DOOR AUTOMATIC ICAP 1 MINI B LD LIT DOOR MINI WHIPPER B NO LIT DOOR...

Page 16: ...16 MANUAL ICAP 1 B LD LIT DOOR MANUAL ICAP 1 MINI B LD LIT DOOR...

Page 17: ...TIMER TERMINAL NO CONNECT ORANGE WIRES TO TIMER TERMINAL N NOTE TO CONVERT TO TIMER CONTROLLED DISPENSE CONNECT BLUE WIRE TO TIMER TERMINAL L1 USE PIGGY BACK TERMINAL PROVIDED DOOR UNIT INDICATOR LIGH...

Page 18: ...18...

Reviews: