Installation (continued)

connection is open. The tank will fill in
approximately 3-4 minutes.

5. After the tank has filled, activate the Heater Switch

(toggle up, lower back of unit). Depending on the
model selected, it will take approximately 15-25
minutes for the water to heat to operating
temperature.

6.  Heat and discard at least one batch of water. 
7. In high altitude locations (over 5000 ft. above sea

level), thermostat may have to be lowered to
prevent boiling. See the 

Adjustments

section if

changes are needed.

NOTE: This procedure is for initial start - up only;
however, steps 4 and 5 must be repeated should the
tank be completely drained. Steps 1 thru 7 must be
repeated should the machine be drained, disconnected,
and reinstalled in a new location.

Cleaning

NOTICE:

All sanitizing agents in the food zone must

comply with 21 CFR 178.1010. Sanitize all food
dispensing units periodically. All parts to be sanitized
must be cleaned first. Cleaning and sanitizing frequency
must follow state and local health department
regulations.

NOTICE:

Do not use cleansers, bleach liquids, powders

or any other substance containing chlorine. These
products promote corrosion and will pit the stainless
steel. USE OF THESE PRODUCTS WILL VOID THE
WARRANTY.

Daily

Wipe the outside of the unit with a damp cloth, using
soap solution or a non-abrasive compound when
required.

Sanitizing

1.  With power to the unit disconnected, fill unit to

capacity. 

2.  Prepare a sanitizing solution in accordance with

local health department regulations. You may also

refer to the US Food and Drug Administration
regulation 21 CFR 178.1010 “Sanitizing Solutions”
and US Environmental Protection Agency 40 CFR
18.940 “Tolerance exemptions for active and inert
ingredients for use in antimicrobial formulations
(Food-contact surface sanitizing solutions)”.

3.  Follow the instructions provided with the sanitizing

agent.

4. Drain all water from the unit slowly.
5. Let all sanitized parts drain and dry naturally. DO

NOT WIPE THEM DRY. 

6. If the unit is not to be used again immediately after

sanitizing - do not rinse with water. If the unit is to
be used immediately after sanitizing - rinse with
water before refilling the unit for further use.

Adjustments

Thermostat Adjustment

1. Remove the two (2) screws from the top cover and

remove cover. The thermostat will be visible. 

2. First, adjust the thermostat by turning the

thermostat knob either clockwise to raise the
temperature, or counter clockwise to lower the
temperature. 

3. If further adjustment is required, remove knob, turn

the adjustment screw, located in the center of the
thermostat shaft, counter clockwise to increase the
temperature and clockwise to decrease the
temperature. 

4. Unit should be set to approximately 203°F.

CAUTION: BURN HAZARD

Water from unit is very hot. Use caution when
pouring or transporting hot water. Accidental spills
may result in severe burns.

CAUTION: BURN HAZARD

Dispenser surfaces and water inside dispenser are very
hot. Use caution when cleaning unit to prevent burns.

CAUTION: BURN HAZARD

Never remove faucet when the liner has water in it.
Switch OFF the power to the unit at the circuit
breaker. Turn off the water line running to the boiler.

WARNING: SHOCK AND BURN HAZARD

To prevent electric shock and burn hazard, this
procedure must be performed by a trained and
qualified service technician.

WARNING: SHOCK HAZARD

Disconnect power before attempting any electrical
repairs.

Summary of Contents for HWD2

Page 1: ...arts Diagram 8 Wiring Diagram 10 Thank you for purchasing this quality water heater For your safety and the safety of others read all warnings and the operator manual before installing or using the pr...

Page 2: ...damage unit and will void warranty To reduce risk of explosion or fire do not use near combustibles WARNING Safety Information 2 Cecilware Hot Water Dispensers Important Safety Information This is the...

Page 3: ...Rough In Drawing CECILWARE 7 9 9 9 15 4 DRIP TRAY OVERFLOW TUBE DISPENSE FAUCET INLET VALVE HEATER SWITCH POWER CORD 15 9 1 0 NH99A Hot Water Dispenser 24 0 23 5 24 3 CECILWARE 9 8 12 0 9 3 0 7 7 0 1...

Page 4: ...imes A filtering system is recommended to remove odors and inhibit lime and scale build up in the unit In areas with extremely hard water a water softener must be installed in order to prevent a malfu...

Page 5: ...R 178 1010 Sanitizing Solutions and US Environmental Protection Agency 40 CFR 18 940 Tolerance exemptions for active and inert ingredients for use in antimicrobial formulations Food contact surface sa...

Page 6: ...5V outlet If water flows in and stops when you pull it out the Valve is working fine Repeat this test a few times The problem may be in the Probe or Water Level Control Board 3 If the water does not f...

Page 7: ...are provides the industry s BEST warranty Visit our website at gmcw com for warranty terms and conditions PROBLEM PROBABLE CAUSE SOLUTION DOES NOT FILL Water supply off Turn water supply on Line cord...

Page 8: ...7 6 3 DESCRIPTION ITEM L532A B012A C032A C223A G267A G266A 80234 77203 L573A K402Q M461A L069A PART NO 1 2 HEATER SWITCH WATER TANK HWD2 LINE CORD 240V 15A 16 17 15 L069A 40799 C770A WATER LEVEL CONT...

Page 9: ...19 WATER INLET VALVE 120V 12 L462A 20 5 4 HWD3 HWD5 FLOAT SWITCH L499A SILICONE HOSE 3 8ID x 16 LG M857A PILOT LIGHT HEATING C165A POWER SWITCH L155A FAUCET 80234 SILICONE HOSE 3 8ID x 16 LG M857A DR...

Page 10: ...10 Cecilware Hot Water Dispensers Wiring Diagram HWD2 120V 240V...

Page 11: ...Hot Water Dispensers Cecilware 11 Wiring Diagram continued HWD3 HWD 5 120V 240V...

Page 12: ...lware 4003 Collins Lane Louisville KY 40245 USA Phone 502 425 4776 Toll Free 800 695 4500 Fax 502 425 4664 Web gmcw com Email info gmcw com 2016 Grindmaster Cecilware Printed in USA 0916 Form CW 329 0...

Reviews: