8
2.
Displays total volume dispensed since last reset.
Reset counter by simultaneously pressing the
▼
and
▲
keys.
DISPENSE COUNTER
#####.# OZ.
3 If the
▼
and
▲
keys are pressed the Dispense Mode will toggle between
“free flow”
and
“position control”.
DISPENSE
MODE FREE
FLOW
DISPENSE
MODE
PORTION
CONTROL
4.
Serving Size in Ounces
is displayed on screen:
Pressing
▼
or
▲
key will decrease or increase the
SERVING SIZE
respectively
SERVING SIZE
##.# OZ.
5.
Pressing any of the
Dispense
keys will cause 5
Dispense
LED(s) of the corresponding
Hoppers to blink and the LCD screen will display the
Gram Throw
for the indicated Hopper.
Please Note: each key needs to be pressed up to 5X for each of the 5 hoppers.
GRAM THROW
SELECT A KEY
6. Pressing
▼
or
▲
key will decrease or increase the
Gram Throw
respectively. GRAM
THROW
HOPPER ###
7.
Pressing any of the
Dispense
keys will cause the
Dispense
LED(s) of the corresponding
Hopper to blink and the LCD screen will display the
Auger Start Time
for the indicated
Hopper.
AUGER START TIME
SELECT A KEY
AUGER START TIME
#.# SEC
8.
Pressing any of the
Dispense
keys will cause the
Dispense
LED(s) of the corresponding
Mixer to blink and the LCD screen will display the
Mixer Start Time
for the indicated Mixer.
MIXER START TIME
SELECT A KEY.
MIXER START TIME
#.# SEC.
9.
Pressing any of the
Dispense
keys will cause the
Dispense
LED(s) of the corresponding
Hopper to blink and the LCD screen will display the
Auger Stop Time
for the indicated
Hopper.
AUGER STOP TIME
SELECT A KEY.
AUGER STOP TIME
#.# SEC.
10. Pressing any of the
Dispense
keys will cause the
Dispense
LED(s) of the corresponding
Mixer to blink and the LCD screen will display the
Mixer Stop Time
for the indicated Mixer.
MIXER STOP TIME
SELECT A KEY.
MIXER STOP TIME
#.# SEC.
11. Fill Constant will cause 3 dispense LED’s of the corresponding mix chambers to light.
Pressing each one will display the water flow “Fill Constant” for each.
FILL CONSTANT
SELECT A KEY.
Pressing
the
▼
or
▲
keys will decrease or increase the flow rate respectively.
FILL CONSTANT
#.# OZ / SEC.