Cecilware GB5MF-IT Operation Manual Download Page 12

 

6

normal operation.  If the offending Hopper is not rinsed after the first Rinse warning additional Rinse Warnings will be generated every five 

minutes until the respective Hopper is rinsed.   

The default setting for this parameter is OFF.

 

 

13.  Rinse Lockout Status 

- This parameter determines whether the Rinse Lockout Option is turned ON or OFF.  If this option is ON the system 

generates a Rinse Lockout if a Hopper has dispensed and has not been Rinsed for a period of time greater than that defined by the Rinse 

Lockout Time. Once a Hopper enters Rinse Lockout the LED’s of the Dispense Keys related to that Hopper will turn OFF thus indicating that 

the Hopper will no longer dispense.  

The default setting for this parameter is OFF.

 

 

14. Rinse Lockout Time

 – This parameter determines the length of time required before entering Rinse Lockout.  The minimum Rinse Lockout 

Time = 1 hour.  The maximum Rinse Lockout Time is 12 hours.  

The default value for this parameter is 4 hours.

 

 

15.  Water Temperature Set Point

 – This parameter determines the required reservoir tank water temperature.  The minimum Water 

Temperature Set Point is 140°F.  The maximum Water Temperature Set point is 203°F.  

The default value for this parameter is 190°F

 

16.  Low Water Temperature Lockout Status

 – This parameter determines whether the Low Water Temperature Lockout Option is turned ON 

or OFF.  If this option is ON the system generates a Low Water Temperature Lockout if the present water temperature is below the value 

defined by the Low Water Temperature Lockout Set Point. Once a Hopper enters Low Water Temperature Lockout, all of the Dispense Key 

LED’s will turn OFF thus indicating that the system will no longer dispense.  

The default setting for this parameter is OFF. 

 

17.  Low Water Temperature Lockout Set Point

 – This parameter determines the minimum reservoir tank water temperature allowed before 

entering Low Water Temperature Lockout.  The minimum Low Water Temperature Lockout Set Point is 125°F.  The maximum Low Water 

Temperature Lockout Set point is 203°F.  

The default value for this parameter is 140°F. 

 

18.  Sleep Mode Status 

– This parameter determines whether the Sleep Mode Option is turned ON or OFF.  If this option is ON and the system 

has not dispensed for four hours the system will enter Sleep Mode.  Once in Sleep Mode the system will reduce the required Water 

Temperature to equal that defined by (10°F + Low Water Temperature Lockout Set Point).  

The default setting for this parameter is OFF. 

 

19. Hopper Status

 – This parameter determines the whether a selected Hopper is turned ON or OFF.  If a Hopper is ON then the Auger Motor, 

Mixer Motor, and Dump Solenoid status checking is enabled and the Hopper is allowed to dispense.  If a Hopper is OFF then Auger Motor, 

Mixer Motor, and Dump Solenoid status checking is disabled and the LED’s of the Dispense Keys related to that Hopper will turn OFF thus 

indicating that the Hopper will no longer dispense.  

The default setting for this parameter is ON.

 

 

20. Blower Diagnostics

 – This parameter will monitor the status of the blower motor and display a warning if it senses a problem.

 The default 

setting for this parameter is OFF. 

 

21. Displayed Units

 – This parameter determines whether the displayed units of measure are English or Metric.  If the Displayed Units 

parameter is set to English then all temperatures are displayed as Degrees Fahrenheit and all volumes are displayed as Fluid Ounces.   If 

the Displayed Units parameter is set to Metric then all temperatures are displayed as Degrees Celsius and all volumes are displayed as 

Milliliters.  

The default setting for this parameter is English. 

 

22. Clock Settings 

– Need to set clock date (DAY, MONTH and YEAR) at the beginning life of the machine.

 

 

 

23. Default Values 

– Resets all parameters to FACTORY SETTINGS.

 

 
 

 
 

 
 

 
 

 
 

 
 

 

Summary of Contents for GB5MF-IT

Page 1: ......

Page 2: ......

Page 3: ...ILLA CARAMEL CINNAMON COFFEE MILK 5 grams 4grams 5 grams 2 2 grams 20 grams CAPPUCINO S ORIGINAL 0 0 0 140 60 Fr VANILLA 135 0 0 140 60 CARAMEL 0 135 0 140 65 CINNAMON 0 0 120 140 65 ADJUSTMENT RANGE...

Page 4: ...110 0 0 55 CARAMEL CINNAMON COFFEE CHOCOLATE MILK 4grams 5 grams 20grams CHOCOLATE HOT CHOCOLATE 0 0 0 35 20 MOCHA 0 0 40 40 10 CARAMEL 135 0 0 55 10 CINNAMON 0 110 0 55 10 ADJUSTMENT RANGE CARAMEL U...

Page 5: ......

Page 6: ......

Page 7: ...l out the drip tray It should contain the following A Set of 4 Adjustable Leveling Legs and a Flare Water Inlet Fitting START UP PROCEDURE 1 Connect the dia copper waterline to the flare water inlet f...

Page 8: ...e Valve behind hoppers mounted on tank 2 Locate adjustment screw on Dispense Valve 3 Using a 3 16 Allen Key or flat screwdriver rotate 1 4 turn at a time CLOCKWISE to decrease water flow or COUNTERCLO...

Page 9: ...control dispensing 3 Rinse Mode This mode becomes active when the Rinse key is depressed with any dispense key The main function of this mode is to allow the operator to initiate an individual Rinse...

Page 10: ...r burnout due to lack of water in the reservoir tank 9 Elimination of dry powder feed at the beginning of a dispense and product dilution at the end of a dispense 10 Extremely accurate dispensing cont...

Page 11: ...turn relative to the activation opening of the Dump Valve A positive value indicates a Mixer starting at some time after the opening of the Dump Valve A negative number indicates a Mixer starting at s...

Page 12: ...is parameter determines the minimum reservoir tank water temperature allowed before entering Low Water Temperature Lockout The minimum Low Water Temperature Lockout Set Point is 125 F The maximum Low...

Page 13: ...key will cause the menu to scroll up and pressing the Rinse key will cause the menu to scroll down 3 The blinking LED s signify which Hopper or Serving Size the displayed parameter corresponds to 4 P...

Page 14: ...e LCD screen will display the Auger Start Time for the indicated Hopper AUGER START TIME SELECT A KEY AUGER START TIME SEC 8 Pressing any of the Dispense keys will cause the Dispense LED s of the corr...

Page 15: ...the following Pressing the and keys will decrease or increase Lockout temperature LOW TEMP LOCKOUT DEG F 22 If the Stop key is pressed the LCD screen will display the following If the and keys are pre...

Page 16: ...e system is waiting to dispense If any of the Dispense Keys are pressed while this screen is being displayed the system will rinse the Hopper corresponding to the depressed key If the Rinse Key is rel...

Page 17: ...n This screen is displayed and the system is shut down when the Fill Solenoid has been continuously energized open filling for more than five minutes during the first fill or more than 30 seconds ther...

Page 18: ...Reset Power Switch OFF and ON 10 High Temperature Lockout Screen Definition This screen is displayed when the present water temperature is 10 F above the water temperature set point SYSTEM ERROR TEMP...

Page 19: ...make sure the water is not touching the Probe Pull the wire and terminal out of the Probe rod If water starts flowing into the tank the Probe may be grounded due to excessive liming Check with Ohm me...

Page 20: ...ROX BLEACH 5 25 CONCENTRATION TO 1 GALLON OF WATER AT ROOM TEMPERATURE 70 90 F Note Always start with an unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span...

Page 21: ...f the mounting plate 4 Pull the Whipper blade off the motor shaft Notice the flat keyway on the shaft and the matching keyway inside the Whipper blade shaft It is important that these two keyways are...

Page 22: ...om mixing chamber a Leaking Water Dispense Valve b Too much water in tank c Mixing Chamber clogged d Water Valve blocked by scales a Replace Water Dispense Dump Valve b Dispense some water from tank c...

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ...P N DESCRIPTION QTY 23...

Page 30: ......

Page 31: ...FETY B190A B190A B138A B138A B000A B000A POWER SWITCH 120V OR 120 240V USE L299A L069A L069A WHIPPER MOTOR LH MIDDLE CD173 RH CD350 SLINGER DISC CD124 CD124 CD173 CD350 CD173 CD350 CHAMBER MOUNT GROMM...

Page 32: ...DISPLAY LIGHT...

Page 33: ......

Reviews: