7
INITIALIZING MODE
The following screen signifies this presence of this mode:
It should be noted that this is the only time the System Software Version Number (V #.##) is displayed.
All other functions of this mode are completely transparent to the operator.
NORMAL MODE
The following is a list of functions performed by this mode:
1.
Dispensing Control
– This mode is responsible for implementing and supervising the dispensing process.
2.
Water Level Control
– This mode is responsible for maintaining the proper level of water in the reservoir tank.
3.
Water Temperature Control
– This mode is responsible for maintaining the required water temperature in the reservoir tank.
4.
Sanitary (Rinse) Functions
– This mode is responsible for annunciating and enforcing rinse warnings and lockouts.
5.
Safety Functions
– This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper operation.
RINSE MODE
A complete rinse is initiated by simultaneously pressing the
Rinse
key and any
Dispense
key.
PROGRAM MODE
General Conventions
(unless otherwise indicated)
1. To
enter
or
exit
Program Mode simultaneously depresses both the
Rinse
key and the
Stop
key until the buzzer sounds (approximately 1.5
seconds).
2. Pressing the
Stop
key will cause the menu to scroll up and pressing the
Rinse
key will cause the menu to scroll down.
3. The blinking LED's) signify which Hopper or Serving Size the displayed parameter corresponds to.
4. Pressing the
▼
or
▲
keys individually will decrease or increase the displayed parameter respectively.
5. Pressing the
▼
and
▲
simultaneously will cause the parameter to revert to a default value.
Functions:
1.
Displays total volume dispensed.
DISPENSE TOTAL
#######.# OZ.
2.
Displays total volume dispensed since last reset.
DISPENSE COUNTER
#####.# OZ.
3.
Shows hopper status, ON/OFF, for each of the 5 hoppers.
HOPPER ON/OFF
SELECT A KEY
4.
Selects status for each hopper by pressing
▼
or
▲
. HOPPER
ON/OFF
#_ IS ON
HOPPER ON/OFF
#_ IS OFF
SERVICE MODE
General Conventions:
1. To
enter
or
exit
Service Mode simultaneously depress both the hidden key behind the
Cecilware Logo
and the hidden key
behind the
Fast Flow Logo
until the buzzer sounds (approximately 1.5 seconds).
2. Pressing the
Stop
key will cause the menu to scroll up and pressing the
Rinse
key will cause the menu to scroll down.
3. The blinking LED(s) signify which Hopper or Serving Size the displayed parameter corresponds to.
4. Pressing the
▼
and
▲
keys individually will decrease or increase the displayed parameter respectively.
5. Pressing the
▼
and
▲
keys simultaneously will cause the parameter to revert to a default value.
Functions:
1.
Displays total volume dispensed.
DISPENSE TOTAL
#######.# OZ.
CECILWARE
DISPENSER V #.##