Unpacking
Carefully lift unit out of shipping container, and inspect
immediately for shipping damage. Your Food Warmer
was shipped in a carton designed to give it maximum
protection. It was thoroughly inspected before leaving
the factory. File any claims for shipping damage or
irregularities directly with the carrier.
Installation
1. Install Quartz Elements
(Tandems & Special Food Warmers with Quartz
Elements Packed Separate)
Place food warmer on workbench or floor with
reflector side up. Remove two screws from access covers
at either end of each individual unit. Remove access
covers and wire guard. Push flag terminals, found on
end of lead wires, onto male tab terminals at either end
of element. Make sure the terminals are pushed on
securely; a loose connection will cause arcing. Locate
element in unit so that groove in porcelain end cap is
nested in notch of element bracket. Hold element in
place and replace one access cover, making sure that
vertical leg of access cover is between element holder
and reflector, secure with two screws. Take wire guard
and insert the two wire ends into the holes in the
mounted access cover. Take second access cover and
slide it over the two wire ends of wire guard and then
position the vertical leg between the element holder
and reflector. Secure with two screws. Your food
warmer is now ready to mount in desired location.
2. Mounting Food Warmer
To avoid burning or charring of supporting surfaces, do
not install closer than 10” above an all stainless surface
or 15” above any other surface. The screws provided in
the ends of all Food Warmers should be used to mount
the food warmer in all cases. These are the correct
length – whether you are using the hanging tabs or
accessory stands or brackets. These screw into weld nuts
in the ends of the food warmers, and sheet metal
screws should not be used.
Mounting tabs are furnished which can be used if you
hang the food warmer.
If you mount the food warmer directly under a shelf,
bend tabs 90° and screw through them into the shelf,
or provide studs welded to the underside of metal
shelves.
Do not punch or drill any other holes in the housing.
The two screws on each end are sufficient, even on long
lengths. Do not attempt to join single units end to end
in the field. Long lengths can be ordered from the
factory, assembled, wired and ready to install.
3. Electrical Connection
These commercial food warmers are intended to be
permanently connected to the source of supply. They
are rated 120, 208, or 240 volts. All supply connections
must be suitable for at least 75°C (167° F) and their size
based on the wattage of the unit must be in compliance
with the National Electrical code (Table 402-5) or the
local electrical code. A ground connection is provided
in the supply box and must be used.
Connect electrical supply wires to the leads in the supply
box using the porcelain wire connectors. Do not
substitute plastic connectors. Always connect at the
supply box furnished. This box can be turned end for
end by removing the two mounting screws inside. Do
not make any other holes in housing for conduit or BX.
Food warmers with supply box on side instead of end,
available on request. Food warmers shipped with
tubular type mounting assemblies will always have
supply boxes on side. See next instruction.
CAUTION:
Do not install closer than one inch
from a wall.