Cecilware FE-100G Operation Manual Download Page 7

 

7

adjustment slot and turn it counter-clockwise to increase or clockwise to 
decrease by-pass flow. At the completion of the brewing cycle, measure 
the volume of the water in the coffee liner. The timer may have to be 
readjusted to obtain the correct volume of water. The proper setting of 
the by-pass will have to be determined by the user.   
 
THERMOSTAT: To adjust the temperature of the water in the urn, turn 
the thermostat knob to “10”and remove the knob without moving the 
thermostat shaft. Place narrow bladed screwdriver (1/8”) into the hollow 
thermostat shaft and engage center adjustment screw. When 
thermometer reading approaches 198F slowly turn the adjustment screw 
clockwise until the burner goes out. Turning the screw counter-clockwise 
will increase the temperature.  
 

MAINTENANCE TIPS 

 
WATER CONDITION: Remove and clean spray head cap and spray head 
disc frequently-typically once a week. To clean the swivel valve, loosen 
nut and remove spray arm assembly from urn. Sediment may be 
removed by inserting a pipe cleaner through small hole in valve. If 
maximum setting of timer fails to deliver enough water, check water 
pump. 
 
OUTSIDE SERVICE: Should you require help, contact the factory, your 
factory representative, or your local service company.  
 

FOR QUALIFIED SERVICE PERSONNEL ONLY 

 
When servicing of unit is required, contact a qualified service agency. 
 
CAUTION: DO NOT TURN ON THERMOSTAT BEFORE ALL PRIMING 
INSTRUCTIONS ARE COMPLETED.  

 

 

WATER FROM COLD WATER SUPPLY LINE DOES NOT ENTER URN 

 
1.

 

Check water supply to shut-off valve and strainer. 

2.

 

Check fuse () on the front panel and replace it if necessary. 

3.

 

If steps 1 & 2 are in order, remove fuse and lift control box door. 

4.

 

Remove two screws from timer panel and remove timer exposing 
terminal strip and electrical wiring. 

5.

 

Replace fuse. 

6.

 

Place wire jumper across terminals () and () on terminal board (). If 
water enters urn, float switch is inoperative and should be replaced 
(see par10). If water does not enter urn, then solenoid valve () or 
small relay () is not functioning. To check solenoid valve, disconnect 
leads from the coil and apply 115V power. If solenoid operates 
replace relay. 

 

Summary of Contents for FE-100G

Page 1: ...MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 LATEST EDITION WARNING IMPROPER INSTALLATION ADJUSTME...

Page 2: ...Code ANSI Z223 1 latest edition 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air openings into the combustion chamber 8 Provide clearance for servicing and proper op...

Page 3: ...pper tubing Construction Type 304 18 8 Stainless Steel Shipping Wt 125 lb INSTALLATION AND OPERATING INSTRUCTION PRE INSTALLATION INSTRUCTIONS The installation of your coffee urn must be made by a lic...

Page 4: ...to it Check with your local Gas Company as to proper pipe size Sealant on all pipe joints must be resistive to propane gas Before attempting to light the coffee urn check all joints for gas tightness...

Page 5: ...LE BLACK J015A 8 1 4 COMP FITTING K039A 9 1 4 ALUM PILOT TUBE H350A 10 3 8 X 3 8 NPT L COMP FITTING K635A 11 3 8 ALUM GAS VALVE TUBE H349A 12 THERMOSTAT RX 2051 12 L622A 13 WIRING HARNESS CH32A 14 8 3...

Page 6: ...erature Brewed coffee should not be held for longer than one hour it should never be reheated if allowed to cool and it should never be boiled TIMER An electronic solid state timer is used to control...

Page 7: ...from urn Sediment may be removed by inserting a pipe cleaner through small hole in valve If maximum setting of timer fails to deliver enough water check water pump OUTSIDE SERVICE Should you require...

Page 8: ...may become necessary to clean out float container to keep float switch in proper operating condition 1 Remove float can cover from top of control box exposing ball float and stem 2 Lift ball from stem...

Page 9: ...ximately 20 second The agitator may be operated independently of the brewing cycle if the agitator button is depressed MAITENANCE The air pump is capable of delivering enough air for proper blending H...

Page 10: ...24 PILOT ASSEMBLY NAT F135A F135A PILOT ASSEMBLY LP F134A F134A 25 ORIFICE NAT F160A F160A ORIFICE LP F161A F161A 26 WASHER SS P813A P813A 27 REDUCING COUPLING 1 4 X 3 8 J041A J041A 28 ORIFICE BRACKE...

Page 11: ...51 SILICONE GASKET M256A M256A 52 STEM VALVE M0251 M0251 53 ADAPTER 1 4 20 M0589 M0589 54 FLOAT SS 3 M0892 M0892 LP CONVERSION KIT L347P L347P 55 WATER GAUGE ASSEMBLY D020A 56 FAUCET ASSEMBLY D017A D0...