Cecilware FE-100G Operation Manual Download Page 1

                                                   

 

              AUTOMATIC GAS 

            

 

 

 

                              

COFFEE URN 

OPERATION MANUAL

 

 

MODEL:

           

 

 

 

FE-100G 
 

 
 
 
 

SPECIFICATIONS 
INSTALLATION 
MAINTENANCE TIPS 
REPAIR PARTS LIST 
WIRING DIAGRAMS 

 
 
 
 
 
 
 

GAS SPECIFICATIONS 

MODEL NO. 

NATURAL GAS  

BTU/HR @ 3.5” W.C. 

PROPANE GAS 

BTU/HR @ 10” W.C. 

          FE-100G 

32,000 

32,000 

 

 

FOR YOUR SAFETY  

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND 

LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. 

 

THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE

ANSI Z223.1 (LATEST EDITION). 

 

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE 

OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. READ 

THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS 

THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. 

 

CECILWARE CORPORATION 

43-05 20

TH

 AVENUE, LONG ISLAND CITY, NY 11105-1295 

 718 

932-1414 

 

                                                           

                                  N529A  08/99 DS 

Summary of Contents for FE-100G

Page 1: ...MABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE THIS INSTALLATION MUST CONFORM WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 LATEST EDITION WARNING IMPROPER INSTALLATION ADJUSTME...

Page 2: ...Code ANSI Z223 1 latest edition 6 Provide adequate air supply and ventilation 7 Provide adequate clearance for air openings into the combustion chamber 8 Provide clearance for servicing and proper op...

Page 3: ...pper tubing Construction Type 304 18 8 Stainless Steel Shipping Wt 125 lb INSTALLATION AND OPERATING INSTRUCTION PRE INSTALLATION INSTRUCTIONS The installation of your coffee urn must be made by a lic...

Page 4: ...to it Check with your local Gas Company as to proper pipe size Sealant on all pipe joints must be resistive to propane gas Before attempting to light the coffee urn check all joints for gas tightness...

Page 5: ...LE BLACK J015A 8 1 4 COMP FITTING K039A 9 1 4 ALUM PILOT TUBE H350A 10 3 8 X 3 8 NPT L COMP FITTING K635A 11 3 8 ALUM GAS VALVE TUBE H349A 12 THERMOSTAT RX 2051 12 L622A 13 WIRING HARNESS CH32A 14 8 3...

Page 6: ...erature Brewed coffee should not be held for longer than one hour it should never be reheated if allowed to cool and it should never be boiled TIMER An electronic solid state timer is used to control...

Page 7: ...from urn Sediment may be removed by inserting a pipe cleaner through small hole in valve If maximum setting of timer fails to deliver enough water check water pump OUTSIDE SERVICE Should you require...

Page 8: ...may become necessary to clean out float container to keep float switch in proper operating condition 1 Remove float can cover from top of control box exposing ball float and stem 2 Lift ball from stem...

Page 9: ...ximately 20 second The agitator may be operated independently of the brewing cycle if the agitator button is depressed MAITENANCE The air pump is capable of delivering enough air for proper blending H...

Page 10: ...24 PILOT ASSEMBLY NAT F135A F135A PILOT ASSEMBLY LP F134A F134A 25 ORIFICE NAT F160A F160A ORIFICE LP F161A F161A 26 WASHER SS P813A P813A 27 REDUCING COUPLING 1 4 X 3 8 J041A J041A 28 ORIFICE BRACKE...

Page 11: ...51 SILICONE GASKET M256A M256A 52 STEM VALVE M0251 M0251 53 ADAPTER 1 4 20 M0589 M0589 54 FLOAT SS 3 M0892 M0892 LP CONVERSION KIT L347P L347P 55 WATER GAUGE ASSEMBLY D020A 56 FAUCET ASSEMBLY D017A D0...

Reviews: