Ni53a.doc                                                                          Page 2 of 4 

 

Water Connection: 

APT Brewers are supplied with 1/4” flared water inlet fittings and flare nuts. 
Use a 1/4” diameter copper tubing to connect brewer to a cold water supply line with a minimum water 
pressure of 20 p.s.i. 
 

HIGHLY RECOMMENDED: 

An external water supply shut-off valve near the brewer and a water purifier filter for 

better tasting fresh brewed tea and coffee beverage. 
 

Electrical Connection: 

APT18 - 120 volt, 1.8 kw

 - Brewers require a single use (dedicated) 15 amp grounded receptacle. 

APT35 - 240 volt,

 

3.5 kw 

- Brewers require a single use (dedicated) 20 amp grounded receptacle. 

APT100 – 120/240 volt,

 

6.4 kw 

- Brewers require a single use (dedicated) 30 amp twist lock 

 grounded receptacle. 
 

TANK PRIMING PROCEDURES  

THESE INSTRUCTIONS ARE FOR INITIAL PRIMING ONLY AND DO NOT HAVE TO BE 
REPEATED FOR NORMAL OPERATION

 

NOTE

: The 

Heater toggle switch,

 located in back of unit, 

or

 under the top cover, must be in the 

 OFF 

 

POSITION.

 

1.

 Remove sample filter pack from brew funnel and insert brew funnel back into machine. 

2.

 Place an empty Air Pot directly under brew funnel. 

3

.  Plug the power cord into a proper receptacle. 

4

.  Activate the RED 

Power Switch

. The tank will start filling automatically.  Allow approximately 4-5 minutes 

for the tank to fill. 

5

.  After the water tank is filled, 

activate

 the 

Heater Switch 

ON POSITION

. Allow approximately 15-20 

minutes for the water to reach a brew temperature (197°F). The heat up time will depend on the water inlet 
temperature, the input voltage and the wattage of the elements in the machine. 

      When the (

Green

Ready

 Light comes on the machine is ready to start brewing. 

6

.  Press Brew Button: 

 

 
BREWING INSTRUCTIONS FOR COFFEE 

 

1. Place a paper filter into brew funnel and add 2.5 oz. of fresh ground coffee into the filter. Place the funnel back 

into brew head of machine. 

2. Unlock the Air Pot Cover and

 

remove the Pump Assembly from the Air Pot. 

3. Place the Air Pot with cover open on the support shelf under the funnel. 
4. When the Green READY light inside the Brew Switch comes on, depress the Brew Switch. 

Note:  Allow 5 to 6 minutes for the complete brew cycle. DO NOT remove funnel from the brewer until it 
has completely stopped dripping 

6.  Remove AIR POT from the brewer, 

insert the air pump tube,

 and snap the top closed. 

7.  Serve fresh brewed coffee from dispenser nozzle by pushing down the round large button on top of the cover. 
 

ADJUSTMENTS: 
 
Timer Adjustments 

(To adjust total volume of COFFEE)  

1. Turn the Power Switch to OFF and remove the top cover. 
2. Locate BREW TIMER and adjust as follows: 
A. For MORE volume, turn TIMER KNOB CLOCKWISE. 
B. For LESS volume, turn TIMER KNOB COUNTERCLOCKWISE. 
C. Go through a complete brew cycle and repeat adjustments if necessary.  

CAUTION:  

Turn TIMER KNOB only in SMALL increments at a time. 

 
 
 

 