Ni53a.doc Page 3 of 4
Thermostat Adjustments
Thermostat is factory set for proper operating temperature of 197°F to 203°F with the adjustment Knob set to the
maximum clockwise position. If field adjustments are needed proceed as follows:
To DECREASE
temperature,
turn the control shaft
slightly to the left
COUNTERCLOCKWISE
.
To INCREASE
temperature, proceed as follows: With the control knob ALREADY TURNED TO ITS MAXIMUM
CLOCKWISE POSITION, locate the small, slotted ADJUSTMENT SCREW inside the hollow shaft. By using a
narrow blade screwdriver
engage the slotted adjustment screw and turn it an 1/8 of a turn slowly to
the left (counterclockwise
) until a click is heard and the Green Ready Light goes OFF.
NOTE: Measure the water temperature at the head with the spray head removed in order to capture a solid
stream of hot water. DO NOT forget to REPLACE spray head afterwards.
In HIGH ALTITUDE locations, (5000 ft. above sea level) the thermostat setting will have to be lowered to
prevent boiling.
MAINTENANCE TIPS.
1. Remove and clean spray head at least once a week. In hard water areas, inspect and clean every other day.
2. If excessive build up of lime is present, de-lime or replace the heating tank.
CLEANING INSTRUCTIONS
Use a mild dishwashing detergent to clean the STAINLESS STEEL, PLASTIC BREW FUNNELS and AIR POTS.
Rinse thoroughly. Clean and Polish the outer surfaces of the STAINLESS STEEL AIR POTS and BREWER with a
STAINLESS STEEL CLEANER & POLISH such as the 3M™ Stainless Steel Cleaner & Polish, which is U.S.D.A.
approved.
TROUBLESHOOTING GUIDE.
Brewing Problems.
Weak Coffee
1. Low water Temperature -------------- Adjust thermostat, should be between 197°F - 203°F
2. Spray Head clogged ------------------- Remove and clean weekly or as needed
3. Too Coarse Coffee Grind ------------ Should be Drip Grind type
4. Not enough Coffee -------------------- Use a minimum of 2 oz. Of coffee
No water from Spray head when brew switch is depressed.
Note: Allow 30 seconds for time delay.
1. Power Switch is off or unit is unplugged.
2. Water Supply is off
3. Hot Water Tank is not full
4. Defective water inlet valve or dispense valve
5. Defective brew switch
6. Defective timer
7. Inlet filter Clogged
Water from spray head not hot.
1. Heater switch is off
2. Thermostat is off or defective.
3. High limit switch has tripped and does not reset – replace high limit switch
3. Tank heater is defective