13

LED Ac Wire speed

.

Indicates that the display 

AL

shows the wire speed in

welding. 

LED AD  current

.

Indicates that the display 

AL

shows a welding current.

during welding always  shows  the measured current;

with the machine at a standstill, if 

Ag

is oFF, shows

the set current. 

LED Af - globular position.

may not be selected

Active in synergic mIg process.

When lit, this signals that the pair of values chosen for

welding may give unstable arcs and splatters.

LED Ag - Hold.

may not be selected. It signals that the values shown

on  the  displays 

AL

and 

AM

(normally  Amperes  and

volts) are those used during last welding. Activated at

the end of each welding session.

LED AH - Voltage.

In all welding processes, it indicates that the display

AM

shows the re-set welding voltage or, if in combi-

nation with LEd 

Ag

lit, the last measured voltage. 

knob AI.

The following values are set: welding current 

A

, wire

speed (

), thickness (

), program number 

PRg

. In

the service functions the following are selected: 

TRg,

SP, HSA, crA, Prf, Pof, Acc, bb, L, Dp, PPf,  Ito,  qc,

Utc, dst, fac

.

In mIg synergic processes when a value is adjusted

the other values are adjusted as well. All these values

are shown on the display 

AL

.

knob AN.

The following sizes are set: 

In synergic  mIg the arc length, in  conventional mIg

the welding voltage.

Inside the service menu, according to the value set by

knob 

AI 

it  selects  the  set  value,  the  activation  or

desactivation of the same, or an additional selection

to be made inside the fuction.

Display AL.

In  all  welding  processes,  it  numerically  displays  the

selections made via the selection key 

AE

and adjust-

ed via the knob 

AI

For  the  welding  current  (LEd 

AD

)  it  displays  the

amperes.

For the wire speed (LEd 

Ac

) it displays the meters per

minute.

For the thickness (LEd 

AB

) it displays the millimeters.

For (LEd 

AA

) it displays the set program number.

In  the  service  functions  the  following  are  selected:

TRg, SP, HSA, crA, Prf, Pof, Acc, bb, L, Dp, PPf,

Ito, fac.

For  the  parameters  within  the  service  functions  that

are shown on the display 

AM

, see the paragraph on

service functions.

When the machine is in the warning mode, it displays a

flashing  warning  (exemple: 

OPN

if  the  lateral    panel  is

open. When the machine is in the error mode it  displays  

Err

.

Display AM.

displays by the number: in synergic  mIg the arc length

and in conventional mIg the welding voltage.

For the welding voltage (LEd 

AH

) it displays the volts. For

the arc length (LEd 

AH

off) it displays a number between

9.9

and 

+9.9

0

being the recommened value.

For the parameters in the mIg service function, that are

shown on the display 

AM

, see the paragraph on 

service

functions 

.

When the machine is in error mode it displays the corre-

sponding error code between 1 and  99.

Selection key AO.

Each  time  this  key  is  pressed,  the  selected  process  is

shown by LEd 

AP/AQ/AR

.

LED AP  Pulsed MIg.

shows  that  the  selected  process  is  the  synergic  mIg

pulsed.

LED AQ  SYNERgIc MIg.

shows that the selected process is synergic mIg.

LED AR  cONVENTIONAL MIg.

shows that the selected process is conventional mIg.

Selection key AU.

Each  brief  pressure  selects  2  stages  mode  (mANUAL)

and  the  4  stages  mode  (AUTomATIC),  the  selection  is

shown on the display 

AL

.

In the 2 stages mode  the machine begins welding when

the  welding  torch  trigger  is  pressed,  and  stops  when

released.

In the 4 stages mode to begin welding press and release

the welding torch trigger; to interrupt, you must press and

release it again.

Selection key AV. 

(

JOB

)

saving and restoring of the stored processes.

To save a working condition (

JOB

), just hold down for at

least  3  seconds  the  key 

AV

,  the  LEd 

AZ

glows,  on  the

display 

AL

the abbreviation 

STO

flashes and on display

AM 

the  number  of  the  first  available  position  flashes.

Knob 

AN

is  used  to  select  the  saving  position;  press

again key 

AV 

until a sound will confirm that it has been

saved and the selected number stops flashing.

To restore the saved number just briefly press key 

AV

and

restore the number by means of  knob 

AN

. Up to 99 pairs

od current/voltage values may be saved.

To  delete  a  saved  number,  press  for  at  least  3  seconds

key 

AV

, turn knob 

AI

until the display 

AL

shows the abbre-

viation 

DEL

and press the key again

AV

for 3 more sec-

onds.

A  current/voltage  parameter  may  be  restored    outside

saving  for both using or changing it. To restore it press

for 3 seconds key 

AV

, display by menas of knob 

AI

the

number  to  be  restored  and  show  on  display 

AL

,  with

knob

AN

the abbreviation 

rcL

; now just press for at least 3

seconds key 

AV

.

LED AZ JOB.

Summary of Contents for MIG 2060 MD

Page 1: ...tential difficul ties in ensuring electromagnetic compatibility in non industrial environments INSTRUcTION MANUAL fOR WIRE WELDINg MAcHINE H F FREQUENCY High frequency H F can interfere with radio navigation safety services computers and communications equipment Have only qualified persons familiar with electronic equipment perform this installation The user is responsible for having a quali fied ...

Page 2: ...nt suitable for synergic pulsed mIg mAg synergic not pulsed mIg mAg and conventional mIg NAg welding developed with inverter technology The power source is equipped with a 2 roller wire feeder This welding machine must not be used to defrost pipes 2 2 ExPLANATION Of TEcHNIcAL SPEcIfIcATIONS This machine is manufactured according to the following standards IEC 60974 1 IEC 60974 10 CL A IEC 61000 3 ...

Page 3: ...duty cycle expresses the percentage of 10 minutes during which the welding machine may run at a certain current without overheating I2 Welding current U2 secondary voltage with current I2 U1 Rated supply voltage 1 50 60Hz 50 or 60 Hz single phase power supply I1 max max absorbed current at the corresponding current I2 and voltage U2 I1 eff This is the maximum value of the actual current absorbed c...

Page 4: ...if the lateral panel is open When the machine is in the error mode it displays Err Display AM displays by the number in synergic mIg the arc length and in conventional mIg the welding voltage For the welding voltage LEd AH it displays the volts For the arc length LEd AHoff it displays a number between 9 9 and 9 9 0 being the recommened value For the parameters in the mIg service function that are ...

Page 5: ...ving menu of the saved working points Selection key AY gas Test When this jey is pressed gas stars flowing to stop it press the key again If the second press does not takes place the gas output is interrupted after 30 seconds Selection key AW Wire test Allows the wire feed with no current or voltage present When this key is held down during the first 5 seconds the wire advances at the speed of 1 m...

Page 6: ...f the low est current lowest speed adjust the arc length of the ref erence speed When the reference speed moves the pre vious settings must also be repeated for the new speed DdP 0 1 3 m min tdP T 25 75 di T Fdp 1 0 5 5 Hz Fig 3 Reference speed 11 PP push pull By using push pull torch Art 2003 function PPf push pull Force is enabled which adjusts the drive torque of the push pull motor in order to...

Page 7: ...tructions under paragraph Service functions Adjust the wire speed and the welding voltage using the knob AI Conventional Mig Welding LEd AR on select the PROg number based on the wire diameter to be used the type and quality of the material and the type of gas using the instructions located inside the wire feed er compartment set the functions in the submenu according to the instructions under par...

Page 8: ...90 ...

Page 9: ...TTRIcO WIRINg DIAgRAM cOLOUR cODE K MARRONE BROWN J ARANCIO ORANGE I ROSA PINK L ROSA NERO PINK BLACK M GRIGIO VIOLA GREY PURPLE N BIANCO VIOLA WHITE PURPLE O BIANCO NERO WHITE BLACK P GRIGIO BLU GREY BLUE Q BIANCO ROSSO WHITE RED R GRIGIO ROSSO GREY RED S BIANCO BLU WHITE BLUE T NERO BLU BLACK BLUE U GIALLO VERDE YELLOW GREEN V AZZURRO BLUE ...

Page 10: ...R 30 TRASDUTTORE TRANSDUCER 31 IMPEDENZA SECONDARIO SECONDARY IMPEDANCE 32 TRASFORMATORE DI POTENZA POWER TRANSFORMER 33 RINFORZO CONVOGLIATORE REINFORCEMENT CONVEYOR 34 PIEDE IN GOMMA RUBBER FOOT 35 PANNELLO ANTERIORE FRONT PANEL 36 FONDO BOTTOM 37 CONNESSIONE CONNECTION 38 PRESA SOCKET 39 TAPPO CAP 40 CORPO ADATTATORE ADAPTOR BODY 41 GHIERA RING NUT 42 CAVO MASSA EARTH CABLE 43 MANOPOLA KNOB 44 ...

Page 11: ...1 2 3 48 6 8 7 4 5 9 10 49 50 51 47 46 11 12 13 20 19 18 17 14 15 16 21 22 23 25 24 26 27 28 52 53 54 29 30 31 32 33 34 35 36 38 37 45 44 43 42 15 23 41 39 40 360 93 ...

Page 12: ...6 ISOLAMENTO INSULATION 412 ENCODER ENCODER 421 BLOCCAGGIO GRADUATO ADJUSTMENT KNOB 422 GUIDAFILO WIRE DRIVE PIPE ASSY 423 GRUPPO GUIDAFILO WIRE GUIDE GROUP 424 ISOLANTE COMPLETO INSULATION ASSY 425 PROTEZIONE MOTORIDUTTORE GEAR MOTOR PROTECTION 426 GRUPPO GUIDAFILO COMPLETO WIRE GUIDE GROUP COMPLETE 428 RULLO TRAINAFILO 0 6 0 8 ROLLER WIRE 0 6 0 8 429 POMELLO KNOB 442 GUIDAFILO ASSEMBLATO WIRE GU...

Page 13: ...MOTORiDUTTORE cOMPLETO wiRE fEED MOTOR cOMPLETE 95 ...

Page 14: ...96 cEBORA S p A via Andrea Costa 24 40057 Cadriano di granarolo BoLogNA Italy Tel 39 051 765 000 Fax 39 051 765 222 www cebora it e mail cebora cebora it ...