Cebora MIG 2060 MD Instruction Manual Download Page 3

12

bers appear on the display, contact technical service.

2.3.2 Overload cut-out

This  machine  is  protected  by  a  thermostat,  which  pre-

vents  the  machine  from  operating  if  the  allowable  tem-

peratures are exceeded. In these conditions the fan con-

tinues to operate and the display 

flashes the abbrevi-

ation “tH.”

3 DEScRIPTION Of POWER SOURcE

(Fig.  1)

A – Socket (-): 

this is where the earth cable is to be con-

nected.

– 

central adapter

: Connect the welding torch.

– 

connector

: For connecting remote controls and the

welding control cable 

Push–Pull Art. 2003.

- Connector : Connector type dB9 (Rs232 serial line)

to use for updating the microprocessor programs.

L - ON/Off switch.

M – Power cable.

N – gas hose.

4  DEScRIPTION Of cONTROL PANEL

(Fig. 2)

AE selection key. 

Each brief pressure selects the size, adjustable via the 

AI

knob.  The  sizes  which  can  be  selected  are  shown  by

LEds 

AA/AB/Ac/AD

.

LED AA  PRg.

Indicates  that  the  display 

AL

shows  the  set  program

number.

LED AB Thickness

.

The

AL

display  shows  the  recommended  thickness

based on the set current and wire speed. Active only in

synergic mIg processes. 

U0.

secondary open-circuit voltage. 

X.

duty  cycle  percentage.  The  duty  cycle

expresses  the  percentage  of  10  minutes 

during  which  the  welding  machine  may  run

at a certain current without overheating. 

I2.

Welding current 

U2.

secondary voltage with current I2  

U1.

Rated supply voltage

1~50/60Hz 50- or 60-Hz single-phase power supply. 

I1 max

max. absorbed current at the corresponding

current I2 and voltage U2. 

I1 eff

This  is  the  maximum  value  of  the  actual 

current  absorbed,  considering  the  duty

cycle. This value usually corresponds to the

capacity  of  the  fuse  (delayed  type)  to  be

used as a protection for the equipment. 

Ip23s 

protection rating for the housing.

grade 

3

as the second digit means that this

equipment  may  be  stored,  but  it  is  not 

suitable for use outdoors in the rain, unless 

it is protected.

suitable for use in high-risk environments.

NoTE: The welding machine has also been designed for

use in environments with a pollution rating of 3. 

(see IEC 60664).

2.3 PROTEcTIONS

2.3.1 Block protection 

In  the  event  of  a  malfunction,  a  flashing  number  may

appear on the display 

M

, with the following meaning: 

52 = 

start button pressed during start-up.

53 = 

start button pressed during thermostat reset.

56 = 

Extended short-circuit between the welding elec-

trode and the material to be welded. 

shut the machine off and turn it back on. If different num-

S

AA

AB

AC

AD

AL

AG

AF

AH

AM

AN

AE

AP

AO

AQ

AR

AU

AV

AZ

AY

AW

AI

Fig. 2

Summary of Contents for MIG 2060 MD

Page 1: ...tential difficul ties in ensuring electromagnetic compatibility in non industrial environments INSTRUcTION MANUAL fOR WIRE WELDINg MAcHINE H F FREQUENCY High frequency H F can interfere with radio navigation safety services computers and communications equipment Have only qualified persons familiar with electronic equipment perform this installation The user is responsible for having a quali fied ...

Page 2: ...nt suitable for synergic pulsed mIg mAg synergic not pulsed mIg mAg and conventional mIg NAg welding developed with inverter technology The power source is equipped with a 2 roller wire feeder This welding machine must not be used to defrost pipes 2 2 ExPLANATION Of TEcHNIcAL SPEcIfIcATIONS This machine is manufactured according to the following standards IEC 60974 1 IEC 60974 10 CL A IEC 61000 3 ...

Page 3: ...duty cycle expresses the percentage of 10 minutes during which the welding machine may run at a certain current without overheating I2 Welding current U2 secondary voltage with current I2 U1 Rated supply voltage 1 50 60Hz 50 or 60 Hz single phase power supply I1 max max absorbed current at the corresponding current I2 and voltage U2 I1 eff This is the maximum value of the actual current absorbed c...

Page 4: ...if the lateral panel is open When the machine is in the error mode it displays Err Display AM displays by the number in synergic mIg the arc length and in conventional mIg the welding voltage For the welding voltage LEd AH it displays the volts For the arc length LEd AHoff it displays a number between 9 9 and 9 9 0 being the recommened value For the parameters in the mIg service function that are ...

Page 5: ...ving menu of the saved working points Selection key AY gas Test When this jey is pressed gas stars flowing to stop it press the key again If the second press does not takes place the gas output is interrupted after 30 seconds Selection key AW Wire test Allows the wire feed with no current or voltage present When this key is held down during the first 5 seconds the wire advances at the speed of 1 m...

Page 6: ...f the low est current lowest speed adjust the arc length of the ref erence speed When the reference speed moves the pre vious settings must also be repeated for the new speed DdP 0 1 3 m min tdP T 25 75 di T Fdp 1 0 5 5 Hz Fig 3 Reference speed 11 PP push pull By using push pull torch Art 2003 function PPf push pull Force is enabled which adjusts the drive torque of the push pull motor in order to...

Page 7: ...tructions under paragraph Service functions Adjust the wire speed and the welding voltage using the knob AI Conventional Mig Welding LEd AR on select the PROg number based on the wire diameter to be used the type and quality of the material and the type of gas using the instructions located inside the wire feed er compartment set the functions in the submenu according to the instructions under par...

Page 8: ...90 ...

Page 9: ...TTRIcO WIRINg DIAgRAM cOLOUR cODE K MARRONE BROWN J ARANCIO ORANGE I ROSA PINK L ROSA NERO PINK BLACK M GRIGIO VIOLA GREY PURPLE N BIANCO VIOLA WHITE PURPLE O BIANCO NERO WHITE BLACK P GRIGIO BLU GREY BLUE Q BIANCO ROSSO WHITE RED R GRIGIO ROSSO GREY RED S BIANCO BLU WHITE BLUE T NERO BLU BLACK BLUE U GIALLO VERDE YELLOW GREEN V AZZURRO BLUE ...

Page 10: ...R 30 TRASDUTTORE TRANSDUCER 31 IMPEDENZA SECONDARIO SECONDARY IMPEDANCE 32 TRASFORMATORE DI POTENZA POWER TRANSFORMER 33 RINFORZO CONVOGLIATORE REINFORCEMENT CONVEYOR 34 PIEDE IN GOMMA RUBBER FOOT 35 PANNELLO ANTERIORE FRONT PANEL 36 FONDO BOTTOM 37 CONNESSIONE CONNECTION 38 PRESA SOCKET 39 TAPPO CAP 40 CORPO ADATTATORE ADAPTOR BODY 41 GHIERA RING NUT 42 CAVO MASSA EARTH CABLE 43 MANOPOLA KNOB 44 ...

Page 11: ...1 2 3 48 6 8 7 4 5 9 10 49 50 51 47 46 11 12 13 20 19 18 17 14 15 16 21 22 23 25 24 26 27 28 52 53 54 29 30 31 32 33 34 35 36 38 37 45 44 43 42 15 23 41 39 40 360 93 ...

Page 12: ...6 ISOLAMENTO INSULATION 412 ENCODER ENCODER 421 BLOCCAGGIO GRADUATO ADJUSTMENT KNOB 422 GUIDAFILO WIRE DRIVE PIPE ASSY 423 GRUPPO GUIDAFILO WIRE GUIDE GROUP 424 ISOLANTE COMPLETO INSULATION ASSY 425 PROTEZIONE MOTORIDUTTORE GEAR MOTOR PROTECTION 426 GRUPPO GUIDAFILO COMPLETO WIRE GUIDE GROUP COMPLETE 428 RULLO TRAINAFILO 0 6 0 8 ROLLER WIRE 0 6 0 8 429 POMELLO KNOB 442 GUIDAFILO ASSEMBLATO WIRE GU...

Page 13: ...MOTORiDUTTORE cOMPLETO wiRE fEED MOTOR cOMPLETE 95 ...

Page 14: ...96 cEBORA S p A via Andrea Costa 24 40057 Cadriano di granarolo BoLogNA Italy Tel 39 051 765 000 Fax 39 051 765 222 www cebora it e mail cebora cebora it ...

Reviews: