Cebora MIG 2060 MD Instruction Manual Download Page 10

pos

DEScRiZiONE

DEScRiPTiON

pos

DEScRiZiONE

DEScRiPTiON

01 MANICO

HANDLE

02 SUPPORTO MANICO

HANDLE SUPPORT

03 COPERCHIO

COVER

04

CHIUSURA

CLOSING

05 ROSETTA

WASHER

06 LATERALE MOBILE

HINGED SIDE PANEL

07 CERNIERA

HINGE

08 RINFORZO

REINFORCEMENT

09 PROTEZIONE

PROTECTION

10 SUPPORTO BOBINA

COIL SUPPORT

11 ISOLAMENTO

INSULATION

12 PIANO INTERMEDIO

INSIDE BAFFLE

13 CIRCUITO DI POTENZA

POWER CIRCUIT

14 PANNELLO POSTERIORE

BACK PANEL

15 CORNICE

FRAME

16 RACCORDO

FITTING

17 PROTEZIONE

PROTECTION

18 INTERRUTTORE

SWITCH

19 ELETTROVALVOLA

SOLENOID VALVE

20 RACCORDO

FITTING

21 CAVO RETE

POWER CORD

22 PRESSACAVO

STRAIN RELIEF

23 PANNELLO ALETTATO

FINNED PANEL

24 LATERALE DESTRO

RIGHT SIDE PANEL

25 COPERTURA

COVER

26 KIT MOTORE CON VENTOLA

MOTOR WITH FAN KIT

27 SUPPORTO VENTOLA

FAN SUPPORT

28 SUPPORTO CONVOGLIATORE

AIR CONVEYOR SUPPORT

29 CONVOGLIATORE ARIA

AIR CONVEYOR

30 TRASDUTTORE

TRANSDUCER

31 IMPEDENZA SECONDARIO

SECONDARY IMPEDANCE

32 TRASFORMATORE DI POTENZA POWER TRANSFORMER
33 RINFORZO CONVOGLIATORE

REINFORCEMENT CONVEYOR

34 PIEDE IN GOMMA

RUBBER FOOT

35 PANNELLO ANTERIORE

FRONT PANEL

36 FONDO

BOTTOM

37 CONNESSIONE 

CONNECTION

38 PRESA

SOCKET

39 TAPPO

CAP

40 CORPO ADATTATORE

ADAPTOR BODY

41 GHIERA

RING NUT

42 CAVO MASSA

EARTH CABLE

43 MANOPOLA

KNOB

44 PROTEZIONE CONNETTORE

CONNECTOR PROTECTION

45

CHIUSURA

CLOSING

46 SUPPORTO MOTORE

MOTOR SUPPORT

47 ISOLAMENTO MOTORE

MOTOR INSULATION

48 TAPPO USB

USB CAP

49 CARTER DI PROTEZIONE

PROTECTION CASE

50

CHIUSURA

CLOSING

51 PULSANTE

SWITCH

52 CIRCUITO SERIALE

SERIAL CIRCUIT

53 CIRCUITO PANNELLO

PANEL CIRCUIT

54 CIRCUITO MICRO

MICRO CIRCUIT

360 MOTORIDUTTORE 

WIRE FEED MOTOR

When ordering spare parts please always state the machine item and
serial  number  and  its  purchase  data,  the  spare  part  position  and  the
quantity.

La richiesta di pezzi di ricambio deve indicare sempre: numero di arti-
colo, matricola e data di acquisto della macchina, posizione e quantità
del ricambio.

92

Summary of Contents for MIG 2060 MD

Page 1: ...tential difficul ties in ensuring electromagnetic compatibility in non industrial environments INSTRUcTION MANUAL fOR WIRE WELDINg MAcHINE H F FREQUENCY High frequency H F can interfere with radio navigation safety services computers and communications equipment Have only qualified persons familiar with electronic equipment perform this installation The user is responsible for having a quali fied ...

Page 2: ...nt suitable for synergic pulsed mIg mAg synergic not pulsed mIg mAg and conventional mIg NAg welding developed with inverter technology The power source is equipped with a 2 roller wire feeder This welding machine must not be used to defrost pipes 2 2 ExPLANATION Of TEcHNIcAL SPEcIfIcATIONS This machine is manufactured according to the following standards IEC 60974 1 IEC 60974 10 CL A IEC 61000 3 ...

Page 3: ...duty cycle expresses the percentage of 10 minutes during which the welding machine may run at a certain current without overheating I2 Welding current U2 secondary voltage with current I2 U1 Rated supply voltage 1 50 60Hz 50 or 60 Hz single phase power supply I1 max max absorbed current at the corresponding current I2 and voltage U2 I1 eff This is the maximum value of the actual current absorbed c...

Page 4: ...if the lateral panel is open When the machine is in the error mode it displays Err Display AM displays by the number in synergic mIg the arc length and in conventional mIg the welding voltage For the welding voltage LEd AH it displays the volts For the arc length LEd AHoff it displays a number between 9 9 and 9 9 0 being the recommened value For the parameters in the mIg service function that are ...

Page 5: ...ving menu of the saved working points Selection key AY gas Test When this jey is pressed gas stars flowing to stop it press the key again If the second press does not takes place the gas output is interrupted after 30 seconds Selection key AW Wire test Allows the wire feed with no current or voltage present When this key is held down during the first 5 seconds the wire advances at the speed of 1 m...

Page 6: ...f the low est current lowest speed adjust the arc length of the ref erence speed When the reference speed moves the pre vious settings must also be repeated for the new speed DdP 0 1 3 m min tdP T 25 75 di T Fdp 1 0 5 5 Hz Fig 3 Reference speed 11 PP push pull By using push pull torch Art 2003 function PPf push pull Force is enabled which adjusts the drive torque of the push pull motor in order to...

Page 7: ...tructions under paragraph Service functions Adjust the wire speed and the welding voltage using the knob AI Conventional Mig Welding LEd AR on select the PROg number based on the wire diameter to be used the type and quality of the material and the type of gas using the instructions located inside the wire feed er compartment set the functions in the submenu according to the instructions under par...

Page 8: ...90 ...

Page 9: ...TTRIcO WIRINg DIAgRAM cOLOUR cODE K MARRONE BROWN J ARANCIO ORANGE I ROSA PINK L ROSA NERO PINK BLACK M GRIGIO VIOLA GREY PURPLE N BIANCO VIOLA WHITE PURPLE O BIANCO NERO WHITE BLACK P GRIGIO BLU GREY BLUE Q BIANCO ROSSO WHITE RED R GRIGIO ROSSO GREY RED S BIANCO BLU WHITE BLUE T NERO BLU BLACK BLUE U GIALLO VERDE YELLOW GREEN V AZZURRO BLUE ...

Page 10: ...R 30 TRASDUTTORE TRANSDUCER 31 IMPEDENZA SECONDARIO SECONDARY IMPEDANCE 32 TRASFORMATORE DI POTENZA POWER TRANSFORMER 33 RINFORZO CONVOGLIATORE REINFORCEMENT CONVEYOR 34 PIEDE IN GOMMA RUBBER FOOT 35 PANNELLO ANTERIORE FRONT PANEL 36 FONDO BOTTOM 37 CONNESSIONE CONNECTION 38 PRESA SOCKET 39 TAPPO CAP 40 CORPO ADATTATORE ADAPTOR BODY 41 GHIERA RING NUT 42 CAVO MASSA EARTH CABLE 43 MANOPOLA KNOB 44 ...

Page 11: ...1 2 3 48 6 8 7 4 5 9 10 49 50 51 47 46 11 12 13 20 19 18 17 14 15 16 21 22 23 25 24 26 27 28 52 53 54 29 30 31 32 33 34 35 36 38 37 45 44 43 42 15 23 41 39 40 360 93 ...

Page 12: ...6 ISOLAMENTO INSULATION 412 ENCODER ENCODER 421 BLOCCAGGIO GRADUATO ADJUSTMENT KNOB 422 GUIDAFILO WIRE DRIVE PIPE ASSY 423 GRUPPO GUIDAFILO WIRE GUIDE GROUP 424 ISOLANTE COMPLETO INSULATION ASSY 425 PROTEZIONE MOTORIDUTTORE GEAR MOTOR PROTECTION 426 GRUPPO GUIDAFILO COMPLETO WIRE GUIDE GROUP COMPLETE 428 RULLO TRAINAFILO 0 6 0 8 ROLLER WIRE 0 6 0 8 429 POMELLO KNOB 442 GUIDAFILO ASSEMBLATO WIRE GU...

Page 13: ...MOTORiDUTTORE cOMPLETO wiRE fEED MOTOR cOMPLETE 95 ...

Page 14: ...96 cEBORA S p A via Andrea Costa 24 40057 Cadriano di granarolo BoLogNA Italy Tel 39 051 765 000 Fax 39 051 765 222 www cebora it e mail cebora cebora it ...

Reviews: