4�4 TIG parameter settings table
Process parameters can be set directly using the following sequence:
♦
press
B
♦
turn
B
to select a single parameter
♦
press
B
to enter parameter modification mode (the parameter turns red)
♦
turn
B
to select the desired value
♦
press
B
again to exit modification mode.
Description
Min�
DEF
Max
UoM
Sol�
Pregas duration
0.1
0.1
10
s
0.1
EVO START (**)
(TIG DC HF)
OFF
OFF
1.0
s
0.1
Hot Start AC
(TIG AC HF)
(TIG MIX HF)
0.1
1.6
6.0
mm
0.1
First Level Current
3
25
I_SET
A
1
First Level Duration
0
0
30
s
0.1
Initial Ramp Duration
0
1.0
10
s
0.1
Main Current
3
100
I2_max(*) A
1
Intermediate current
5
50
I2_max(*) A
1
Final Ramp Duration
0
1.0
10
s
0.1
Crater Current Duration
0
0
10
s
0.1
Crater Current
3
10
I_SET
A
1
Duration
postflow
0.1
10
50
s
1 (0.1-25) s
5 (25-50) s
Table 1
(*)
Item
I2_max
380
340A
381
500A
394
270A
395
340A
396
450A