I-203

ABOUT THE OUTPUT:

 During operation of the circuit, and according to its load, a fluctuation or an output malfunction may occur. If this happens, install 

an anti-spark circuit between the two contacts of the relay used in connection

SUR LA SORTIE:

 Pendant le fonctionnement du circuit, et selon sa charge, une fluctuation ou un dysfonctionnement de sortie peuvent se produire. Si 

cela se produit, l'installation d'un circuit anti-étincelle entre les deux contacts du relais utilisés dans le cadre.

CONSIDERACIONES SOBRE LA SALIDA  :

 Durante el funcionamiento del circuito, y según sea su carga, podrá producirse una fluctuación o un 

incorrecto funcionamiento de la salida. Si esto ocurre, instale un circuito anti-chispas entre los dos contactos del relé utilizados en la conexión .

OPERATION:

 There are two operating modes, Program mode where operating parameters are configured, and working mode where it acts as a timer.

Programming. There are 5 programmable parameters, Luggage, Back or Forward Account Scale timing relay connection mode and Pause features.

ENTRY PROGRAM IS ONLY GETTING PRESSED ENTER TO OPERATE KEEPING THE CIRCUIT POWER.

After about 3 seconds, the first programming parameter will appear, decreasing the display lighting, condition will be maintained while operating in 
programming.
Changes on each parameter is performed by closing the Up or Down inputs or pressing the corresponding keys. If kept closed, the forward or 
decrease at a faster rate.
Change to the next parameter programming occurs whenever you press Enter.
The recording is performed only activating / closing the Trigger input, after which the circuit gets the standard working mode.
The recording of the changes you make is over all programming parameters, whether or not modified. 
The output programming without changes occurs for a period exceeding 20 sec inactivity., By closing the reset input or by disconnecting power.
Luggage. Parameter indicating the maximum number of circuit timing or stop.
Account Account Back or Forward. Selecting "----", the timer will start in the figure entered, concluding the timing when it reaches zero. Selecting "-
Up", the circuit starts timing from scratch, stopping when you reach the setpoint number.

Timing scale :

 The digit display and timing will occur in minutes and seconds if the selected parameter is zero, "S 0". If the parameter is set to one, "S 

1", timing and value in answer display hours and minutes.
Relay Connection Mode. Selecting "Out - |" relay activation will occur when the timer reaches the preset number (entered in zero count up or count 
down). Selected "Out | -" relay activation occurs while the preset number is reached.
Pause. If "PA.of" is selected, the timing will occur without pauses, since activation until the time is consumed Luggage. Selected "PA.on" in this 
parameter, the timer pauses and to perform such reactivations are necessary during a timeout.

Work mode :

 The start or trip timing Trigger occurs when the input is activated. If the device has been configured without pause, any activation of 

Trigger or keep active during the course of a delay will have no impact. With the ability to pause enabled, each activating Trigger, start or pause 
alternatively at 
timer. The pause condition will be reflected with a flashing display while it is maintained. During the first 30 seconds in addition, the display will 
decrease its intensity.
When the timer runs out the timer, a reset must be performed in order to be activated again.
Reset. Activating this input deteiene timer and clears the timer returns to its initial state, the relay disconnects if it was connected and allows the circuit 
to be re-shot.
Relay. According to the program mode, the relay will activate when you get the timing or completion while this is occurring.
Check programmed parameters. Each activation of Up or Down, show you the different scheduling parameters, hiding log timing, that will not be 
stopped or affected, and reappear after a few seconds after leaving the doctor. (It should be seen that the i Up Down buttons are connected in parallel 
with said inputs and thus also assumes the same operations).

Recovery of lost power.

  If JP1 is closed, the module will retrieve and display the display the last value of the time delay before disconnecting power. 

If you do not want to enable this function should be released two pins of JP1. 

FONCTIONNEMENT: : 

Il existe deux modes de fonctionnement , le mode de programme où les paramètres d'exploitation sont configurés , et le mode 

de travail où elle agit comme un minuteur .
Programmation . Il ya 5 paramètres programmables , bagages, Retour ou le mode de connexion de relais compte avant Echelle de synchronisation et 
Pause caractéristiques .

PROGRAMME D'INSCRIPTION EST SEULEMENT MISE appuyé sur Entrée FAIRE FONCTIONNER MAINTENIR le circuit .

Après environ 3 secondes , le premier paramètre de programmation apparaît , ce qui diminue l'éclairage d'affichage , l'état est maintenu pendant 
l'utilisation dans la programmation.
Modifications sur chaque paramètre est effectuée en fermant les entrées vers le haut ou vers le bas ou en appuyant sur les touches correspondantes. 
Si maintenues fermées , l' avant ou diminuer à un rythme plus rapide.
Passer à la prochaine programmation des paramètres se produit chaque fois que vous appuyez sur Entrée .
L' enregistrement est effectué uniquement l'activation / la fermeture de l'entrée de déclenchement , après quoi le circuit reprend le mode de 
fonctionnement standard.
L'enregistrement des modifications que vous apportez est sur ​​tous les paramètres de programmation , modifié ou non .
La programmation de la sortie sans changement se produit pour une période supérieure à 20 secondes d'inactivité . , Par fermeture de l'entrée de 
réinitialisation ou en couper l'alimentation.
Bagages . Paramètre indiquant le nombre maximal de calendrier ou d'arrêt circuit .
Compte Compte Précédent ou Suivant. Sélection "----" , la minuterie démarre dans le chiffre inscrit , concluant le moment où il atteint zéro . Sélection 
" Up" , le circuit commence à compter à partir de zéro , arrêter quand vous atteignez le nombre de point de consigne.