INFORMATION ABOUT THE OUTPUT.

During the operating mode and according to its load, it could happen a

fluctuation or an incorrect working of the
output. In such case, you have to install an
anti-spark circuit between both contacts of
the used relay, as it is indicated on the
schedule.

100nF/400 V.

47

1/2W.

?

Alimentación de la Carga.

OUTPUT CONFIGURATION.

As we have previously communicated you, the DA-03 output could be adjusted according

to Flip-Flop or Timed mode. The Flip-Flop mode, when the code is correct, will maintain connected the relay till you press
the Flip-Flop push button. The Timed mode will maintain connected the relay during the adjusted time.
To configurate the module on the Flip-Flop mode, you have to place the switch Nº2 of the “Setup Relay” on ON position.
To configurate the output on timed mode, place the switch Nº2 on OFF position. See schedule hereafter.

TIMED OUTPUT.

. If you configurate the output on timed mode, the module offer the possibility to use two different

scales, seconds or minutes. For instance, if you have inserted the number 9, this number could be in seconds or minutes
scale according to your needs.
To select the seconds sacle, you have to place the switch Nº1 of the “Setup Relay” on OFF position. To select the minutes
scale, place the switch Nº1 on ON position. See the schedule hereafter.

OUTPUT CONNECTION.

The DA-03 output is controlled by a relay, and accept any device up to 5 A. The relay have

three output terminals: The normally open quiescent (NO), the normally closed quiescent (NC) and the common.
This mechanism operate like a switch with two terminals NO and Common. For the inverse function you have to use the
NC and Common. In the drawing hereafter, you could see a typical connection with a 12 V D.C and 230 V A.C devices.

ACCESS CONTROL WITH KEYBOARD

ON

ON

Setup

Relay

Setup

Relay

Timed / Flip-Flop.

Timed / Flip-Flop.

Relay configured with Timed output.

To configurate the Timed output

on Seconds scale

Relay configured with Flip-Flop output

To configurate the Tmed output

on Minutes scale

Sec. / Min.

ON

Setup

Relay

Timed / Flip-Flop.

Sec. / Min.

ON

Setup

Relay

Timed / Flip-Flop.

Sec. / Min.

Sec. / Min.

220 V. AC. CONNECTION

12 V. DC. CONNECTON

12 V. DC

Common

Common

(NO) Normally Open

(NO) Normally Open

(NC) Normally Closed

(NC) Normally Closed

Load,

Device

Load,

Device

220 V. AC.