L1
›› Set Mode
*******************************
Set Valve Model
F69
►►►►►►
Set Type
*******************************
Set Flow Rate Unit
↓
Values
Programming steps
Screen
LT1
Under the Technician mode (L2)
1. Select “Set Mode” parameter by (▼▲)
Set Mode
Set Mode
2. Press “validation” and select Filter or Softener (LT1)
○
Filter
3. Press “validation” to return to the Technician mode (L2)
●
Softener
LT2
Under the Technician model (L2)
Set Valve Model
↑
Set Valve
1. Select “Set Valve Model” parameter by (▼▲)
○ F63
Model
2. Press “validation” and select F63/65/68/69/82/79 (LT2)
○ F65
3. Press “validation” to return to the Technician mode (L2)
○ F68
● F69
LT3
Under the Technician model (L2)
1. Select “Set Type” parameter by (▼▲)
Set Type
2. Press “validation” and select Time clock Type or Meter Type (LT3)
○
Time clock Type
3. Press “validation” to return to the Technician mode (L2)
●
Meter Type
A. Technical Mode Selection
During the 6 seconds the screen L1 to connect the unit to the mains appears, press "regene down" key
to
simultaneously and hold for about 3 seconds to enter Menu Technical L2 (Background).
B. Adjust Parameters
Under the Technician mode (L2), you can adjust the following parameters. Operation mode (Filtration/Softening),
Valve model, control type, flow uni
t, volume of resins, i
nterval of regener
ation days
, backw
ash time, Brine and s
how
resin time, brine and fast rinse time.
Set Type
53 NASSER - CEASA
Summary of Contents for Kivu LCD UF HF 160
Page 1: ...MANUAL DE INSTRUCCIONES ES INSTRUCTION MANUAL EN MANUEL D INSTRUCTIONS FR ...
Page 2: ......
Page 38: ...38 NASSER CEASA ...
Page 39: ...INSTRUCTION MANUAL EN ...
Page 40: ......
Page 75: ...MANUEL D INSTRUCTIONS FR ...
Page 76: ......
Page 113: ......
Page 114: ......
Page 115: ......