Sequence of screens in SERVICE:
∩
12:30:25
∩
12:30:25
∩
12:30:25
Water System
Water System
Water System
Service
Service
Service
Water
Water
Water
Remaining:
X.XXm
³
Cu.F.R.:
X.XXm
³
/h
Regen.
Time:
2:00
State 1
State 2
State 3
Programming process of the valve. USER mode
Values
Programming steps
Screen
LR1
Whe
n (∩) indicator in the upper left, press and
Set Parameters
maintain (▼ ▲) for 5 seconds, until it disappears (∩)
1. Press key "validation" and enter the menu "Set Parameters"
> Set Time of Day
LR1 indicates the screen as follows. The parameter "set time of day" is
Set Regen. Time
It automatically selected.
Set Water Hardness
Watch
2. Then press “validation” and the display shows the
LR2 screen; the value of hours "12" will blink, and by (▼ ▲)
LR2
the value of the current time in that time will be adjusted.
3. Then be pressed again "validation", and the value min
Set Time of Day
"30" blinks, and by (▼ ▲) a minute value is set.
12:30
4. Finally, press "validation" and hear a "beep" that
confirms memorization of change
1. Press and enter the menu “set parameters”, as shown in
screen.
2. Press (
▼
) and select the “set. Regen. time” parameter;
LR3
Then click “validation” and see the LR3 screen.
Regeneration
The hour value “02" blinks and by (▼▲) will adjust the
Set Regen. Time
time
Value of hours.
02:00
3. Then again press “validation” and the value minutes
"00" blinks and by (▼▲) a minute value is set.
4. Finally, press “validation” and hear a “beep” that
Confirms memorization of change.
1.Pulsar "validation" and enter "Set parameters" menu,
as shown in Figure LR1.
LR4
2. Press the (▼) 2 times and select the “Set Water
Water
Hardness”; then press “validation” and LR4 screens appears.
Set Water Hardness
hardness
The hardness value "150" will blink, and by (▼▲) is introduced
150 mg/L
The hardness value measured at the entrance.
3. Finally, press “validation” and hear a “beep” that confirms
the memorization of changes.
After adjusting the parameters, the display shows the volume of water that can be treated.
Technical parameters setting mode (Background)
Valve programming process. TECHNICIAN mode.
52
NASSER - CEASA
Summary of Contents for Kivu LCD UF HF 160
Page 1: ...MANUAL DE INSTRUCCIONES ES INSTRUCTION MANUAL EN MANUEL D INSTRUCTIONS FR ...
Page 2: ......
Page 38: ...38 NASSER CEASA ...
Page 39: ...INSTRUCTION MANUAL EN ...
Page 40: ......
Page 75: ...MANUEL D INSTRUCTIONS FR ...
Page 76: ......
Page 113: ......
Page 114: ......
Page 115: ......