1 2 3 4 5
default value master code).
2 beeps are emitted to confi rm
entry in programming mode.
2. Press A0 to program the key-in
keypad time and the keys lit time.
- 1 beep is emitted.
-
Enter the time in 10th of second –
10
for 10 seconds up to
99
for 99 seconds
The backlighting dims 10 seconds after
the last keypress or switches off after
entering a valid code.
- Press
00
for permanent illumination keys.
- One beep is emitted to validate the time.
3. Press A1 to program relay 1
output time (door release time).
-
1 beep is emitted.
- For a latched output enter the time
in seconds –
01
for 1 second up to
99
for 99 seconds.
- Press
00
for a toggled output.
- One beep is emitted to validate the time.
4. Press B to exit from programming mode.
2 beeps are emitted to confi rm that
the keypad is in stand-by operating mode.
4 beeps indicate a data computing error.
F. RESET MASTER CODE
- On normal operating mode, set switch 1
(4 position switch SW1) to the ON position.
-
Wait 1 second and then remove the jumper
by setting switch 1 to the OFF position.
- One beep is emitted.
- The master code is restored to its default
value
1 2 3 4 5
in 5-digits code and
1 2 3 4
in 4-digits code.
G. CHANGING THE ENTRY CODE BY THE USER
- Permission to change the code by the user
is determined by the position of switch 2
(4 position switch SW1).
- Set switch 2 to the OFF position to prevent
codes being changed, and to the ON position
to allow change).
1. Enter the code currently being used.
- The access relay is activated:
- A beep is emitted.
2. Enter the 2-digits sub master code.
-
Relay 1, on fi rst use:
A
and
B
.
- Relay 2, on fi rst use:
1
and
3
.
- A beep is emitted to authorise the change.
3. Enter the new user code.
2 beeps are emitted to confi rm the new code.
4.
Check the new user code to be sure
of the modifi cation.
H.
SETTING A SUB MASTER CODE
1. Enter the master code twice
(
1 2 3 4 5
default value master code).
2 beeps
are emitted to confi rm entry in programming mode.
2. Relay 1 (Group 1): Type A7.
Relay 2 (Group 2): Type A8.
- This input enables you to enter new digits
for changing user codes for each group.
- A beep is emitted.
- Type the two change digits.
- A second beep is emitted to confi rm
the programming.
Eg:
Type
A7
then enter the two change digits.
Then repeat the operation by typing
A8
.
3. Press B to exit from the programming mode.
2 beeps are emitted to confi rm that the
keypad is in stand-by operating mode.
I. AUDIBLE FEEDBACK
The audible signal is enabled in programming
mode and when the relay is energised
after a valid code. To enable the audible
feedback on a key press:
1. Enter the master code twice
(
1 2 3 4 5
default value master code).
2 beeps
are emitted to confi rm entry in programming mode.
2. Press AA.
-
One beep is emitted.
- Press
0
to disable the audible signal
during a keypress.
- Press
1
to enable the audible signal
during a keypress.
- One beep confi rms the new setting.
3. Press B to exit from programming.