CDVI SUBLIM Installation Manual Download Page 12

EN

12

cdvi.com

cdvigroup.com

SUBLIM

Illuminated Weatherproof Keypad with remote electronics

  INSTALLATION MANUAL

1] PRODUCT PRESENTATION

  No mechanical keys.

  Backlit.

  Stainless steel and polycarbonate.

  Laser engraving of the numbers  

  and letters on the inside

  of the polycarbonate material.

  Free voltage.

  Installation with Torx

®

 screws

  Protection of the printed circuit  

   board by varnish coating.

  100 user codes.

 

   

 Audible and visual feedback.

 Length of specifi c cable supplied (between

  the SUBLIM and the remote control): 3m. 

 2 relays.

 Dimensions (L x W x D): 205 x 175 x 63mm.

 Input voltage : 12 to 24V ac or 12 to 48V dc.

 Consumption (3 relays cont keypad):

  

- 12V ac > Standby 90 mA,

  - 12V ac > 2 relays activated 260 mA,

   - 24V ac > Standby 120 mA,

  - 24V ac > 2 relays activated 150 mA,

   - 12V dc > Standby 275 mA,

   - 12V dc > 2 relays activated 350 mA,

   - 24V dc > Standby 140 mA,

   - 24V dc > 2 relays activated 175 mA.

Remote controller supplied 

with the SUBLIM coded keypad…

2] NOTES AND RECOMMENDATIONS

Wiring reminder

- The wiring distance between the SUBLIM and the  

  remote controller must be within a maximum of 3 m. 

- Take care not to pass your wires close

  to «High voltage» cables (e.g.: 230 V AC).

Recommended power supplies

There are two suitable power supplies

for this Digicode

®

 keypad: ARD12 or BS60.

Security advice

- The geo-positioning of the digital keys is

  programmed at the factory. Once the unit has    

  been installed on site, repeat the geo-positioning  

  of the digit keys, as explained in the manual.

- For security advice reasons, change 

  the factory default master code.

- When selecting a master code and user code  

 

  avoid simple codes (example : 

3 4 5 6 7

).

Installation recommendations

- To optimize the use of Sublim and prevent  

 

  unwanted interference, make sure the keypad

  is mounted on a fl at, solid surface and not

  subject to vibration.

Mount the keypad on a fl at surface to avoid 

  any vandalism and to insure the best mounting.

- To secure the system from back electromagnetic   

  fi elds do not forget to mount the varistor 

  in parallel on the lock.

- It is essential that the SUBLIM’s remote controller  

  is installed in an enclosed environment, protected  

  from external weather conditions.

+15°C to +35°C

Certifi cation

CE

WEEE

IP54

Thank you for buying our products and for the confi dence you placed

in our company.

Summary of Contents for SUBLIM

Page 1: ...oup Products FR EN FRANCAIS ENGLISH INSTALLATION MANUAL Illuminated Weatherproof Keypad with remote electronics Range Digicode MANUEL D INSTALLATION Clavier cod r tro clair lectronique d port e Gamme...

Page 2: ...llez modi er le code ma tre usine par celui de votre choix Lors du changement du code ma tre usine et de la cr ation des codes utilisateurs vitez les codes trop simples ex les suites 3 4 5 6 7 Rappel...

Page 3: ...outil sp ci que cl m le coud e Pour naliser le montage de ce produit placez le cache vis 2 Positionnez les 3 chevilles plastiques dans les trous Puis Fixez le fond du SUBLIM sur le support de votre ch...

Page 4: ...e le code ma tre 1 2 3 4 5 Hors tension r initialise la m moire code ma tre effacement des codes utilisateur param tres par defaut usine 3 Modi cation du code par l utilisateur en position ON 4 Non ut...

Page 5: ...le clavier sous tension 4 La programmation g ographique des touches se fait par le clavier dans l ordre suivant 1 2 3 8 9 0 A et B 5 Tambouriner avec la pointe d un crayon sur le centre de la touche 1...

Page 6: ...mis Tapez les 4 ou 5 termes du nouveau code ma tre Un bip sonore est mis pour con rmer la programmation 3 Tapez B pour sortir de la programmation Deux bips sont mis pour con rmer le retour au mode no...

Page 7: ...oriser le changement 3 Composez le nouveau code d ouverture Deux bips sonores con rment la validation du nouveau code et le retour un fonctionnement normal 4 V ri ez la m morisation du nouveau code en...

Page 8: ...n relais 2 A4 Nombre de termes Tapez le code ma tre 2 x bips 1 x bip 1 x bip 1 x bip 1 x bip 1 x bip 10 99 sec 00 continue 10 D faut 01 99 sec 00 bistable 01 D faut 01 99 sec 00 bistable 01 D faut La...

Page 9: ...s de modi cation relais 2 AA Signal sonore 00 99 Programmation des codes 1 x bip 1 x bip 1 x bip 1 x bip Tapez A ensuite B 2 Bips sont mis 1 x bip OK 4 bips erreur 1 x bip OK 4 bips erreur 1 x bip OK...

Page 10: ...e d port e MANUEL D INSTALLATION 10 cdvi com cdvigroup com Rangs Code Nom Pr nom 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Rangs Code Nom Pr...

Page 11: ...Nombre de termes code Commande A5 Code ma tre Commande A6 RAZ m moire A B Clignotement rapide Commande A7 Code modi cation relais 1 commande A8 Code modi cation relais 2 Commande AA Avec sans avertis...

Page 12: ...Take care not to pass your wires close to High voltage cables e g 230 V AC Recommended power supplies There are two suitable power supplies for this Digicode keypad ARD12 or BS60 Security advice The g...

Page 13: ...drill bit and 35mm hole depth and the hole wiring access Fasten the PROFIL100EC keypad to the back plate by using the supplied M4x8 Torx screw and Allen spanner hardware To nalize installation of the...

Page 14: ...initializes the master code 1 2 3 4 5 With the power off reinitializes the memory master code deletion of user codes default factory settings 2 Change of code by the user in the ON position 3 Not used...

Page 15: ...f the new master code Digit teach programming 1 Switch the keypad off 2 Set switch SW2 Refer to page 4 to the ON position 3 Switch the keypad on 4 Keys are programmed by the keypad in the following or...

Page 16: ...o con rm that the master code is programmed 3 Press B to exit from the programming mode 2 beeps are emitted to con rm that the keypad is in stand by operating mode D ADDING CHANGING OR DELETING A USER...

Page 17: ...W1 Set switch 2 to the OFF position to prevent codes being changed and to the ON position to allow change 1 Enter the code currently being used The access relay is activated A beep is emitted 2 Enter...

Page 18: ...meout A2 Relay 2 timeout A4 Number of digits 1 x beep 1 x beep 1 x beep 10 99 seconds 00 continuous 10 Default 01 99 seconds 00 bistable 01 Default 01 99 seconds 00 bistable 01 Default The value 4 or...

Page 19: ...for changing relay 1 A8 Digits for changing relay 2 Sound signal 00 99 1 x beep 1 x beep 1 x beep 1 x beep Press A then B 2 Beeps are emitted 1 x beep OK 4 beeps error 1 x beep OK 4 beeps error 1 x b...

Page 20: ...Group 2 From row 60 to row 99 REMINDER Digit place Code Name Forname 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Digit place Code Name Forname...

Page 21: ...h 1 ON Master code RESET Command A4 Number of code digits Command A5 Master code Command A6 Memory reset A B Rapid ashing Command A7 Relay 1 change code Command A8 Relay 2 change code Cmd AA with with...

Page 22: ...FR SUBLIM Clavier cod r tro clair lectronique d port e MANUEL D INSTALLATION 22 cdvi com cdvigroup com...

Page 23: ...FR SUBLIM Clavier cod r tro clair lectronique d port e MANUEL D INSTALLATION 23 cdvi com cdvigroup com...

Page 24: ...ble G0301FR0297V06 CDVI FRANCE EXPORT Phone 33 0 1 48 91 01 02 Fax 33 0 1 48 91 21 21 CDVI AMERICAS CANADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone...

Reviews: