1] PRODUCT PRESENTATION
No mechanical keys.
Backlit.
Stainless steel and polycarbonate.
Laser engraving of the numbers
and letters on the inside
of the polycarbonate material.
Free voltage.
Installation with Torx
®
screws
Protection of the printed circuit
board by varnish coating.
100 user codes.
Audible and visual feedback.
Length of specifi c cable supplied (between
the SUBLIM and the remote control): 3m.
2 relays.
Dimensions (L x W x D): 205 x 175 x 63mm.
Input voltage : 12 to 24V ac or 12 to 48V dc.
Consumption (3 relays cont keypad):
- 12V ac > Standby 90 mA,
- 12V ac > 2 relays activated 260 mA,
- 24V ac > Standby 120 mA,
- 24V ac > 2 relays activated 150 mA,
- 12V dc > Standby 275 mA,
- 12V dc > 2 relays activated 350 mA,
- 24V dc > Standby 140 mA,
- 24V dc > 2 relays activated 175 mA.
Remote controller supplied
with the SUBLIM coded keypad…
2] NOTES AND RECOMMENDATIONS
Wiring reminder
- The wiring distance between the SUBLIM and the
remote controller must be within a maximum of 3 m.
- Take care not to pass your wires close
to «High voltage» cables (e.g.: 230 V AC).
Recommended power supplies
There are two suitable power supplies
for this Digicode
®
keypad: ARD12 or BS60.
Security advice
- The geo-positioning of the digital keys is
programmed at the factory. Once the unit has
been installed on site, repeat the geo-positioning
of the digit keys, as explained in the manual.
- For security advice reasons, change
the factory default master code.
- When selecting a master code and user code
avoid simple codes (example :
3 4 5 6 7
).
Installation recommendations
- To optimize the use of Sublim and prevent
unwanted interference, make sure the keypad
is mounted on a fl at, solid surface and not
subject to vibration.
-
Mount the keypad on a fl at surface to avoid
any vandalism and to insure the best mounting.
- To secure the system from back electromagnetic
fi elds do not forget to mount the varistor
in parallel on the lock.
- It is essential that the SUBLIM’s remote controller
is installed in an enclosed environment, protected
from external weather conditions.
+15°C to +35°C
Certifi cation
CE
WEEE
IP54
Thank you for buying our products and for the confi dence you placed
in our company.