background image

The installer’s choice

 

cdvigroup.com

Reference : 

G0301FR0356V04

Extranet :

 EXE-CDVI_IM DGLPMWLC-DGLIMWLC CMYK A5 FR-EN 04

  All the information contained within this document 

(pictures, 

dr

awing, features, specifi

 cations and dimensions)

could be perceptibly different 

and 

can be changed without 

prior notice.

Toutes 

les informations mentionnées à 

titre indicatif

 sur le présent document (photos, 

dessins, 

car

actéristiques

techniques et dimensions) 

peuv

ent v

arier 

et 

sont susceptibles de modifi

 cations sans 

notifi

 cation préa

la

ble.

G0301FR0356V04

CDVI

FRANCE  + EXPORT

Phone: +33 (0)1 48 91 01 02

Fax: +33 (0)1 48 91 21 21

CDVI

 AMERICAS

[CANADA - USA]

Phone: +1 (450) 682 7945

Fax: +1 (450) 682 9590

 

CDVI

BENELUX

[BELGIUM - NETHERLAND - LUXEMBOURG]

Phone: +32 (0) 56 73 93 00

Fax: +32 (0) 56 73 93 05

CDVI

TAIWAN

Phone: +886 (0)42471 2188

Fax: +886 (0)42471 2131

CDVI

SUISSE

Phone: +41 (0)21 882 18 41

Fax: +41 (0)21 882 18 42

CDVI

CHINA 

Phone: +86 (0)10 62414516

Fax: +86 (0)10 62414519

CDVI

IBÉRICA

[SPAIN - PORTUGAL]

Phone: +34 (0)935 390 966

Fax: +34 (0)935 390 970

CDVI

ITALIA

Phone: +39 0321 90 573 

Fax: +39 335 127 89 96

CDVI

MAROC

Phone: +212 (0)5 22 48 09 40

Fax: +212 (0)5 22 48 34 69

CDVI

SWEDEN

[SWEDEN - DENMARK - NORWAY - FINLAND]

Phone: +46 (0)31 760 19 30

Fax: +46 (0)31 748 09 30

CDVI

UK

[UNITED KINGDOM - IRELAND]

Phone: +44 (0)1628 531300 

Fax: +44 (0)1628 531003 

CDVI 

DIGIT

FRANCE 

Phone: +33 (0)1 41 71 06 85 

Fax: +33 (0)1 41 71 06 86

CDVI Group

FRANCE  

(Headquarter/Siège social)

Phone: +33 (0)1 48 91 01 02

Fax: +33 (0)1 48 91 21 21

Summary of Contents for DGLIMWLC

Page 1: ...ller s choice cdvigroup com DGLPMWLC DGLIMWLC Indoor Outdoor 13 56 MHZ Mifare Card Readers Wiegand Lecteurs Mifare 13 56 MHz intérieur extérieur Wiegand ENGLISH ENGLISH EN FRANCAIS FRANCAIS FR DGLPMWLC DGLIMWLC ...

Page 2: ...products and for the confidence you placed in our company Wiegand 26 30 ou 44 bits Available in version Stainless steel Réf DGLIMWLC Polycarbonate Réf DGLPMWLC PCB sealed in epoxy Audible and visual feedback Surface mount Technologie 13 56 Mhz Connecting by 6 40 4 pair cable Input voltage 12V DC Consumption 100 mA Complies with European R TTE directive 99 5 EC and harmonised standards ETS 301 489 a...

Page 3: ... 30 bits Wiegand ST2 44 bits Wiegand ST5 ST6 LED Control 1 ST2 ST1 ST5 B H D0 C3 ST6 ST4 1 Set up jumper in OV with CTV900A and CAA470A 26 bits 30 bits 44 bits Set up jumper in 5V ST4 Pulls up 12 V ou 5V Open collector outputs Select the output voltage according to the installation Pulls up on 12 V Pulls up on 5 V No pull up ST5 ST6 ST5 ST6 1 1 ST1 ST2 ST1 ST2 ST1 ST2 26 BITS 30 BITS 44 BITS ST4 S...

Page 4: ... In standard when a card or a tag is placed within the reader the orange LED is activated and the buzzer emit a tone The Centaur controller can manage the LED and the buzzer to program other operations DIPSWITCH 3 POSITIONNING OFF Pull up 5V ON Pull up 12V Pulls up 12 V or 5V Open collector outputs Select the output voltage according to the installation DIPSWITCH 4 POSITIONNING Terminal 8 pins Inp...

Page 5: ...nsferred from bit 7 to bit 0 2 Second parity 1 bit odd parity for the last 12 bit Bit 1 Bit 2 to bit 25 Bit 26 Even Parity on bit 2 to bit 13 Data 24 bit Odd Parity on bit 14 bit 25 Example code of the badge is 0100166A37 1 0001 0110 0110 1010 0011 0111 0 Parity 1 1 6 6 A 3 7 Parity 2 The code transmitted is in hexadecimal format 166A37 Parity 1 0 if the number of 1 in bit 2 to bit 13 is even 1 if...

Page 6: ...0000 0001 0001 0110 1011 0110 1 Parity 1 0 0 6 6 A 3 7 Parity 2 The code transmitted is in hexadecimal format 0166A37 Parity 1 0 if the number of 1 in bit 2 to bit 15 is even 1 if the number of 1 in bit 2 to bit 15 is odd Parity 2 0 if the number of 1 in bit 16 to bit 29 is odd 1 if the number of 1 in bit 16 to bit 29 is even 44 bit Wiegand Format Output 44 bit hexadecimal format The output format...

Page 7: ...e that there are no pieces missing in the mounting kit Get the right tools according to the installation type Drill screw drivers metre tape and follow the mounting instructions of the reader 7 MOUNTING INSTRUCTIONS 3 DGLPMWLC Insert the plastic anchors in the mounting holes connect the cable to the terminal block Then fasten the reader with the wooden screws Leave an area to access the cable to m...

Page 8: ...ion FCC CFR 47 part 15 compliance Merci pour l achat de ce produit et pour la confiance que vous accordez à notre entreprise Wiegand 26 30 ou 44 bits Disponible en version Inox saillie Réf DGLIMWLC Polycarbonate saillie Réf DGLPMWLC Electronique résinée Signalisation lumineuse et sonore Montage en saillie Inox Technologie 13 56 Mhz Raccordement par câble 4 paires 6 10e Alimentation 12 V DC Consomma...

Page 9: ...WLC Bornier 8 points alimentation 12VDC 0V H Clock D0 Data 0 D1 Data 1 B Buzzer V LED verte R LED rouge ST1 ST2 Sélection sortie Wiegand Format de sortie Standard 26 bits Wiegand ST1 30 bits Wiegand ST2 44 bits Wiegand ST5 ST6 Voyants 1 ST2 ST1 ST5 B H D0 C3 ST6 ST4 1 Pulls up à 12 V Pulls up à 5 V Pas de pull up ST5 ST6 ST5 ST6 1 1 ST1 ST2 ST1 ST2 ST1 ST2 26 BITS 30 BITS 44 BITS ST4 ST4 1 1 ST4 1...

Page 10: ...badge active la LED orange et déclenche le buzzer La centrale Centaur permet néanmoins de définir d autres états pour la LED et le buzzer POSITIONNEMENT DIPSWITCH 3 OFF Pull up 5V ON Pull up 12V Pulls up 12 V ou 5V Pour les sorties à collecteur ouvert il y a deux niveaux de sorties possibles Permet à l utilisateur de choisir la tension de sortie en fonc tion de l installation POSITIONNEMENT DIPSWIT...

Page 11: ...e poids fort en premier 2 2ème parité 1 bit parité impaire des 12 derniers bits Bit 1 Bit 2 à bit 25 Bit 26 Parité paire sur bit 2 à bit 23 Donnée 24 bits Parité impaire sur bit 14 à bit 25 Exemple pour un badge dont le code hexadécimal est 0100166A37 1 0001 0110 0110 1010 0011 0111 0 Parité 1 1 6 6 A 3 7 Parité 2 Le code émis est 166A37 en hexadécimal Parité 1 0 si le nombre de 1 dans bit 2 à bit...

Page 12: ...1 0 0 6 6 A 3 7 Parité 2 Le code émis est 0166A37 en hexadécimal Parité 1 0 si le nombre de 1 dans bit 2 à bit 15 est paire 1 si le nombre de 1 dans bit 2 à bit 15 est impaire Parité 2 0 si le nombre de 1 dans bit 16 à bit 29 est impaire 1 si le nombre de 1 dans bit 16 à bit 29 est paire Format Wiegand 44 bits Format 44 bits hexadécimal La communication s effectue par une liaison de type Wiegand 4...

Page 13: ...ge 7 Rappels et préconisations Après avoir vérifié que le kit de montage est complet vous allez pouvoir procéder à l installation finale de votre lecteur Réunissez le matériel approprié Perçeuse tournevis mètre et suivez les recommandations de montage qui correspondent au lecteur que vous allez installer 7 MONTAGE 3 DGLPMWLC Placez les chevilles plastiques dans les trous connectez les fils aux bornie...

Page 14: ...8 NOTES 14 cdvigroup com FR DGLPMWLC DGLIMWLC Lecteurs Mifare 13 56 MHz Wiegand MANUEL D INSTALLATION ...

Page 15: ...15 cdvigroup com FR DGLPMWLC DGLIMWLC Lecteurs Mifare 13 56 MHz Wiegand MANUEL D INSTALLATION ...

Page 16: ...NADA USA Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone 41 0 21 882 18 41 Fax 41 0 21 882 18 42 CDVI CHINA Phone 86 0 10 62414516 Fax 86 0 10 62414519 CDVI IBÉRICA SPAIN PORTUGAL Phone 34 0 935 390 966 Fax 34 0 935 390 970 CDVI ITALIA Phone 39 03...

Reviews: