-17-
Connecting Electric Lock
Door Lock Controlled with Internal Power
Door Lock Controlled with Dry Contact
EB
*
LOCK
Jumper position on 2&3
1 2 3
L1 L2 PL S+ S-
Take off the jumper
1 2 3
L1 L2 PL S+ S-
LOCK
POWER
SUPPLY
WIRING
1.
A fail secure (power on to unlock) should
be used
.
2.The door lock
output
is limited to 12V
at a
maximum of
250mA.
3.
Connect the jumper across
on position 2
and 3 before connecting
the lock
.
4.
NOTE:
The door lock control is not
timed from Exit Button(EB).
5.The
Unlock Mode
must be set to 0 ( default).
1. An external power supply must be used
in accordance to the lock requirements.
2.The in
ternal
relay contact is restricted
to 230Vac
at
1A or 24Vdc
at
1A.
3.The jumper must be
removed
before
connecting
the lock etc
.
4.Set the
Unlock Mode
according to
the
lock type.
•
Power-on-to-unloc
k, fail secure
:
Unlock Mode=0 (default)
•
Power-off-to-unlock
, fail safe
:
Unlock Mode=1
*
CDV
-RLC relay actuator is
required
for 2nd lock connection.