background image

-7-

SETUP INSTRUCTIONS

KEY_1

KEY_2

KEY_3

KEY_4

KEY_SET

LED_UNLOCK
LED_TALK

LED_NAME

RF CARD

Order

Setting items

Setting range

Default value

1

Setting door station address

0~3

0

2

Setting door station 

calling mode

Standard/Group calling mode

Standard calling mode

3

Setting camera resolution

High/Low

High

6

Setting the nameplate 

illumination mode

On/Off/Auto

On

7

Setting night view LED 

Zoom mode

Full screen mode

Alternate switching mode

This section explains the settings of each 
function,

 

please refer to the table

 below

:

Each operation is indicated by the 

LED

 

indicator

 and the buzzer

 on the unit, 

5

Setting the unlock time

01 to 99 seconds

1 seconds

4

Setting the unlock mode

            

0

 = O

pened/1

 = C

losed

0

 = O

pened

On/Off/Auto

Auto

illumination mode

Alternate switching mode

9

Setting image display mode

Ring

 Once

Ring 

Continuous

No ring-back tone

Function 

Programming

To 

carry out programming of

 the function 

required

, the metal front panel

 must be 

removed

. Please refer to 

Fig 1

.

Summary of Contents for CD97-4ID

Page 1: ...al carefully to ensure safe and correct operation Keep this manual well for future reference RF CARD RF CARD 2 WIRE SYSTEM CDV97 Series Fisheye Camera Door Station With Proximity Access Control CD97 4...

Page 2: ...de 8 Setting Camera Resolution 10 Setting Unlock Mode 10 Setting Unlock Time 11 Setting Nameplate Illumination Mode 11 Setting Night View LED Illumination Mode 12 Setting Ring back Tone 12 Setting Ima...

Page 3: ...10 9 1 3 4 8 7 6 5 12 13 2 1 Microphone 2 UNLOCK indicator 3 CALL indicator 4 Call button 5 Nameplate 6 Front panel 7 Speaker 8 Night view LED 9 Camera lens 10 Rain cover 11 Mounting hook 12 Connectio...

Page 4: ...than 1700 Rain cover Main Unit 1 2 3 4 5 The distance between the top of main unit and rain cover should be not less than 3mm Main unit Rain cover 1 Drill holes in the wall to match the size of wall...

Page 5: ...R Motion Detector Connect Port 12V GND PIR L1 L2 PL S S Main Connect Port Motion Detector Connection Port To connect external PIR motion detector PL External lock power input connect to the PSU positi...

Page 6: ...or lights up a single beep will be heard and the lock relay will activate If an unauthorised user card tag is presented three beeps will be heard and the lock relay will NOT activate Please note that...

Page 7: ...D Zoom mode Full screen mode Alternate switching mode This section explains the settings of each function please refer to the table below Each operation is indicated by the LED indicator and the buzze...

Page 8: ...Beep Beep Beep ID 0 1st door station ID 1 2nd door station ID 2 3rd door station ID 3 4th door station PROGRAMMING INSTRUCTIONS A total of 4 addresses can be configured Addresses can be modified eithe...

Page 9: ...address 01 by default Call button B calls the monitor with address 02 by default Call button C calls the monitor with address 03 by default Call button D calls the monitor with address 04 by default C...

Page 10: ...tion of the camera can be changed at any time between high or low resolution High resolution is the default setting to change the setting please follow the steps below If still in programming mode the...

Page 11: ...ameplate illumination mode to Auto Press KEY_3 By default the unlock time is 1 second the time setting range is 1 99 seconds To change the unlock time follow the steps below There are 3 illumination m...

Page 12: ...gain to close ring back call tone Press KEY_1 There are 3 working modes for the night view LED Normally on Normally off and Auto Auto is the default setting to change this setting please follow the st...

Page 13: ...econds then switch to Zoom image When answering a call When the door station calls a monitor the camera image will be displayed on screen there are 3 modes for the displayed image Alternate switching...

Page 14: ...use Proximity card frequency 125kHz Full screen mode When answering the call the image will be displayed on Zoom mode for 5 seconds then switching to Full screen as a reminder to enter talking status...

Page 15: ...CARD DELETE UNLOCK Indicator OFF TALK Indicator OFF Buzzer Beep Beep UNLOCK Indicator Blink one time TALK Indicator OFF Buzzer Beep Press KEY_2 button After powering on within 10s press and hold on K...

Page 16: ...ETE to ID card window in standby Show the MASTER CARD ADD to ID card window Show the MASTER CARD ADD again format is activated Show the MASTER CARD DELETE to ID card window in standby Show user cards...

Page 17: ...position 2 and 3 before connecting the lock 4 NOTE The door lock control is not timed from Exit Button EB 5 The Unlock Mode must be set to 0 default 1 An external power supply must be used in accordan...

Page 18: ...oor station ID 3 4th door station L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S L1 L2 PL S S To monitors RF CARD RF CARD RF CARD RF CARD A maximum of 4 door stations can be connected to the system Please ens...

Page 19: ...de 1 DIP6 on Slave 3 BUS IM BUS DS PC6A AC 100 240VAC Code 1 DIP6 off Slave 1 RF CARD SCU GSM TPS QSW Please set door station to group calling mode if there are more than 4 monitors on the system Refe...

Page 20: ...onal functional module BDU Star Topology Wiring With DBC4A1 in Standard Mode BDU Bus amplifier module RLC Relay Lock module DBC4A1 Branch distributor The door station is compatible with all monitors w...

Page 21: ...er or diluted soap and water to clean off dirt The unit is weather resistant However do not use high pressure water cleaners on the door panel directly Excessive moisture may cause problems with the u...

Page 22: ...limited in the DT system Using different cables may also affect the maximum distance which the system can reach Cable and distance unit m Cable Usage A B 2 IM B 16 IM Twisted cable 2x0 75mm2 60 100 40...

Page 23: ...23 B A C 2 2 DBC4A1 RF CARD PC6A Cable and distance unit m Cable Usage A B C Twisted cable 2x0 75mm2 60 60 30 Twisted cable 2x1mm2 80 80 40 APPENDIX Star Topology Wiring Mode With DBC4A1...

Page 24: ...The design and specifications can be changed without notice to the user Right to interpret and copyright of this manual are preserved DT ENG DT607 V1...

Reviews: