5
cdvigroup.com
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
Recommended Wiring
Specifications
Equipment
Wire Type
Size
Maximum
Length
Ethernet
CAT 5/5e
-
100m (300ft)
RS485 bus
(Daisy Chain)
Belden 9841, 9842 or equivalent
(2 or 4 conductor shielded)
24AWG (0.51mm)
1220m (4000ft.)
* The Minimum Size Equipment Conductors for the AC mains required are 14 AWG if made of Copper or 12
AWG if made of Aluminium or Copper-Clad Aluminium. Do not use any switch-controlled outlets to power the
system.
System Resources
Doors
10 doors
Cards and users
10,000 cards and users
Schedules
1000 Schedules each supporting up to 100 time periods
Buffered Events
25,000 events
Holidays
100 holidays
Access Levels
1000 access levels
Operating Temperature
-20°C to +70°C (-4°F to +158°F)
Humidity
0% to 85% (non-condensing)
System Autonomy
Full Distributed Architecture (100% Off-line Operation)
Firmware
Online Upgradeable
PCB Dimensions
19.9cm (7.83”) x 12.38 cm (4.875”)
Cabinet Dimensions
29 cm (11.4”) high, 28 cm (11”) wide, 8 cm (3.15”) deep
Inputs
Box Tamper
Normally Closed (N.C.) contact