17
cdvigroup.com
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
EN
ADH10
ATRIUM - Schlage Integration Module (Control up to 10 Schlage Door Handles)
INSTALLATION MANUAL
Power Connections
Do not power up the ADH10 Controller until all connections are completed.
The module operates from any 120/240 Vac sources using the supplied AC/DC power supply and provides fully
monitored power solutions using:
• Smart Battery Deep discharge prevention with automatic electronic cut-off.
• Programmable & Adaptive battery charging algorithm (250mA (default), 320mA, 500mA, or 1A).
• Intelligent battery monitoring & charging algorithms allowing optimum performance using standard
lead acid batteries.
• Real Time Monitoring algorithm for ‘Battery Low/Disconnect/Reversal’ and ‘Insufficient Main Power’.
AC Source
The AC to DC power supply is pre-installed in the ADH10 Controller box but needs to be connected to the PCB.
1. Connect the AC/DC power
supply output cable to
the ADH10 Controller DC
Power Supply “+” and “-”
terminals. The polarity
of the wires is identified
as shown in the following
picture.
2. Connect the pre-installed
green power LED to the
ADH10 Controller DC Power
Supply “+” and “-” terminals; in parallel with the AC/DC power supply. The red wire goes on the
“+” terminal and the white on the “-” terminal. Make sure that all wires are properly inserted and
tightened.
See “Recommended Wiring” chapter for more information on wiring type, size, and maximum length.
The Minimum Size Equipment Conductors for the AC mains required are 14 AWG if made of Copper or 12
AWG if made of Aluminium or Copper-Clad Aluminium. Do not use any switch-controlled outlets to power
the system. The system is to be connected to a 15A receptacle or circuit.
For PERMANENTLY CONNECTED EQUIPMENT, a readily accessible disconnect device shall be
incorporated external to the equipment.
For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be
easily accessible.
LOCAL
BUS
POWER
SUPPL
Y
BA
TT
.
TAMPER
1
2
3
Power Supply
LED Indicator
Power Supply:
Input: 120-240Vac, 1.2A,50Hz/60Hz
Output: 24Vdc @ 2.5A
(Do not connect to a receptacle controlled by a switch).
Fuse Rating:
250VAC, 2.5 A
(-55C to +125C)
Red
White
Neutral
Live
Ground