CDVI ATRIUM ADH10 Installation Manual Download Page 1

The Installer’s Choice

cdvigroup.com

 ENGLISH

EN

ADH10

ATRIUM

Schlage Integration Module

Summary of Contents for ATRIUM ADH10

Page 1: ...The Installer s Choice cdvigroup com ENGLISH EN ADH10 ATRIUM Schlage Integration Module...

Page 2: ...ches 16 Power Connections 17 AC Source 17 AC Terminal Fuse 18 Battery Backup 19 LED Indicators 20 System overview 21 6 WARRANTY TERMS CONDITIONS 22 Thank You for buying our products and for the confid...

Page 3: ...cluded with every ADH10 making this unit an industry leader in efficiency and simplicity Control 10 door handles On board Ethernet Port with AES 256 bit encryption Auto detect technology 10 000 users...

Page 4: ...s INSTALLATION MANUAL 2 NOTES AND RECOMMENDATIONS Free Technical Support For technical support in U S or Canada call 1 866 610 0102 Monday to Friday from 8 00 a m to 8 00 p m EST For international tec...

Page 5: ...inium or Copper Clad Aluminium Do not use any switch controlled outlets to power the system System Resources Doors 10 doors Cards and users 10 000 cards and users Schedules 1000 Schedules each support...

Page 6: ...IN Do Not Connect to a Receptacle Controlled by a Switch On Board Protection Fuseless auto resume Battery Against reversal short current limited monitored Power output specifications Battery Backup Ba...

Page 7: ...tal cabinet and connection diagram label AC power cord Metal cabinet accessory kit Installation kit Wall Switch and a white wire 115mm with a log at each end Bolts and Nuts Wall Switch Spacer Door Swi...

Page 8: ...oltage Capacity Length Width Height YUASA NP7 12 12 Volt 7 Ah 151mm 5 94 65mm 2 56 97 5mm 3 84 YUASA NP4 12 12 Volt 4 5 Ah 90mm 3 54 70mm 2 76 106mm 4 17 Multiple Conduit Knock outs Two 19 05mm 0 75 o...

Page 9: ...TIONS The box needs to be prepared before fixing it to its location INSTALLING THE TAMPER SWITCHES Installing tamper switches allows the ADH10 to detect when the cabinet door is opened and or when the...

Page 10: ...INSTALLATION MANUAL Cabinet Side View Cabinet Door Nut Spacer Spacer Screw Spacer Install the wall tamper switch using the supplied bolts and nuts as shown in the following picture Install the tamper...

Page 11: ...er switch to the bracket then mount the bracket on the mounting flange Door Tamper Switch Bracket Door Tamper Switch Mounting Flange Install the door tamper switch by aligning the switch holes to the...

Page 12: ...oor 1 Remove the box door knock out 2 Insert the lock in the hole 3 Slide the U metal bracket into the lock groove as shown in the picture to secure the lock in place Alternatively or complementary to...

Page 13: ...NSTALLATION MANUAL Fixing the Box to its Location Install the box to its location using 4 screws not supplied as shown in the following picture If the wall tamper switch is used make sure that the tam...

Page 14: ...e Integration Module Control up to 10 Schlage Door Handles INSTALLATION MANUAL Installing the ADH10 Controller Install the 5 supplied PCB fasteners in the holes identified in red in the images below L...

Page 15: ...POWER SUPPLY BATT TAMPER ADH10 LOCAL BUS to ADH10 Door Handle Controller GWE NDE Lock Gateway or GND TDA TDB AD 300 GND RDA RDB PIM400 485 12V GND Rx Tx You can connect up to 10 GWE gateways or PIM40...

Page 16: ...ch terminal and the other end to the wall tamper switch terminal 2 Connect the other terminal of the door tamper switch to the TMP terminals using the supplied wire 3 Connect the other terminal of the...

Page 17: ...s identified as shown in the following picture 2 Connect the pre installed green power LED to the ADH10 Controller DC Power Supply and terminals in parallel with the AC DC power supply The red wire go...

Page 18: ...he fuse using the same fuse type 250VAC 2 5 A Time Lag Slow Blow Operating Temperature 55o C to 125o C Permitted replacements a Littelfuse P N 021802 5MXP b Schurter P N 0034 3121 c Various means any...

Page 19: ...d terminals with the battery leads supplied 12Vdc 7Ah rechargeable acid lead or gel cell backup battery UL ULC YUASA NP7 12 recommended Europe CDVI B7AH recommended Ensure proper polarity Various mean...

Page 20: ...mitted received Green LED LINK Ethernet network detected Green LED 2 COM PORT AUX Green LED 12 V output power activated RX Green LED flashing Data received on local bus TX Green LED flashing Data tran...

Page 21: ...ireless Lock NDE Wireless Lock PIM400 485 Panel Interface Module GWE Gateway Each PIM400 485 or GWE can manage up to ten locks ADH10 can manage up to ten PIM400 485 and or GWE ADH10 firmware version 3...

Page 22: ...ay not be held responsible in the event of loss or non presentation of the form The 5 Year Warranty only applies to products installed by a skilled and experienced personal with the necessary trade qu...

Page 23: ...elements considered as consumables such as fuses lights and batteries for example Failure or malfunctioning as a result of an accident poor storage conditions unsuitable assembly bad utilization or h...

Page 24: ...Phone 1 450 682 7945 Fax 1 450 682 9590 CDVI BENELUX BELGIUM NETHERLAND LUXEMBOURG Phone 32 0 56 73 93 00 Fax 32 0 56 73 93 05 CDVI TAIWAN Phone 886 0 42471 2188 Fax 886 0 42471 2131 CDVI SUISSE Phone...

Reviews: