CONNECTING READERS AND KEyPADS
The 2-Door Controller allows automatic format detection and decoding of the connected reader/keypad. When
installing a keypad with a Wiegand output, the keypad’s “D0” and “D1” wires should be connected to the same
terminals as the reader (the reader output must be open collector). Depending on the required application
more than one keypad and/or reader can be connected to the same terminals.
Most readers and keypads have built-in buzzers and LEDs. These should be connected to module’s
programmable outputs (B1, G1, R1 for READER 1 and B2, G2, R2 for READER 2). These are open collector
outputs capable of sinking 100mA. Please note that the B, G and R outputs are programmed for a 7-wire reader
by default. Typically, a blue/red/green indicator on the reader will inform the card user that access has been
granted (changes from blue to green), access has been denied (changes from blue to flashing red), door is
locked (from blue to brief red) or door is unlocked by a schedule (changes from blue to brief green). Typically,
the reader buzzer or an external sounding device will inform the card user that the door has been left open
after a valid access or the door has been forced open. The functions of all these outputs are programmable
through the ATRIUM software. The ATRIUM system is configured for the SOLAR, STAR and NANO models of
readers by default (Standby blue).
READER 2
INPUTS
LOCAL
BUS
READER 1
BA
TT
.
POWER
SUPPL
Y
BELL
DOOR 2
12V
Z6
GND
Z7
Z8
C1
NO1
NC1
C2
NO2
NC2
GND
Z9
Z10
12V
Z1
GND
Z2
Z3
GND
Z4
Z5
AC22
2-Door Controller
GALEO/W
Wiegand
Keypad
Red
Black
Green
White
Brown
NANOPB
Mini
Proximity
Reader
Red
Black
Green
White
Orange
Yellow
Brown
2 reader inputs (Multiple Protocol Support)
Supports the most popular 26-bit Wiegand and Track 2 protocols
1
2
See chapter 2 “Recommended Wiring” for more information on wiring type, size, and maximum length.
Compatible readers and keypads:
•NANOPW (White) and NANOPB (Black)
•STARPW (White) and STARPB (Black)
•SOLARPW (White) and SOLARPB (Black)
•DGLP FN WLC26
•DGLP WLC26
•DGLI F WLC26
•DGLI WLC26
•DGLP60WLC
•KCPROXWLC (Reader & Keypad)
•DGLM (Magstripe)
And most popular Wiegand
readers & keypad
For an up-to-date list of which keypads and readers are supported, refer to the ATRIUM Software
Manual or visit our web site at www.cdvigroup.com.
Please note that the 2-Door Controller provides 12Vdc output. Connecting a device (keypad or reader)
requiring a different voltage may damage the reader or keypad and invalidate the 2-Door Controller
warranty.