If you are mounting the unit against the wall, we advise following directions:
leaving a clearance of
minimum 20 cm (*) from the floor
– thus assuring enough air flow at the suction side
- and
minimum 1 m from the ceiling
, thus avoiding that the unit will re-suck its own dried air.
In order to ensure a proper air circulation above the floor, we advise
never to mount the unit more than 1 m
above the floor.
For vibration-free mounting of the unit you can use an optional:
WALL MOUNTING SET
1 SET = 2 (AMT40/65//92M/100) or 3 (AMT140/142M) screw bolts with rubber vibration damper and plug
+ 2 (or 3) distance tubes with rubber vibration damper.
When using this wall mounting set the unit will be mounted 20 mm from the wall: the front side can easily be
lifted when cleaning/replacing the filter
ATTENTION
WHILE MOUNTING, CAREFULLY SEE TO IT THAT THE RUBBER DAMPER IS NEVER USED
AS AN AID TO FORCE A TOOL UPON.
WRONG MOUNTING WILL RESULT IN EXTRA TENSION/CHARGE ON THE DAMPER WHICH CAN CAUSE
CRACKS. THE LOAD BEARING CAPACITY OF THE DAMPER WILL NO LONGER BE GUARANTEED:
THE DAMPER CAN TEAR OUT AND THE UNIT MAY FALL OFF THE WALL.
If the bottom of the unit is visible, you can fit (always supplied separately) a bottom grate
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
O
O
N
N
T
T
H
H
E
E
F
F
L
L
O
O
O
O
R
R
Can be mounted on the floor when using optional 20 cm (*) high closed feet.
.
Place the unit on the feet and screw it down with the bolts and nuts that are supplied with the feet.
When the unit has been screwed down to the feet it can be lifted and put in its final position.
ATTENTION: make sure that the cables are not jammed between the back wall, bottom or feet.
Electrical cables and - if you are using flexible connections - pipes for heating and any swimming pool condenser
can be passed through the feet.
For freestanding mounting, the unit should be protected against pulling over.
The unit can be levelled by screwing the levelling screws on the bottom of the front side of the unit in or out.