Supporting material must be sufficiently strong
To prevent resonance, make best use of sound insulating material – see
Fitting or attaching the unit to wooden floors or walls is not recommended. This requires special precautions
(anti-rumble materials).
The units must always be levelled.
The units may only be installed one way up in a way that the compressor is always upright.
The suction of the unit should be at least 2,5 m from the water surface (protection volume – directions ARAI).
IGNORING THESE GUIDELINES CAN CAUSE DAMAGE
W
W
O
O
R
R
K
K
I
I
N
N
G
G
A
A
R
R
E
E
A
A
On installation of the unit, ensure there is sufficient space to allow practical and safe maintenance to the unit: front
side of the unit. However, electrical and hydraulic connections have to be done through the side of the unit
(minimum 100 cm working space).
C
C
O
O
N
N
D
D
E
E
N
N
S
S
A
A
T
T
I
I
O
O
N
N
D
D
R
R
A
A
I
I
N
N
The condensation drain is connected via the bottom or via the back of the unit.
The condensation outlet is a 22
∅
mm flexible hose
which must be connected to a PVC outlet pipe
∅
32 mm, ideally
fitted with an odour trap (siphon).
To prevent water splashing into the unit and any undesirable odours, the connection must be made airtight to
prevent the intake of air via the outlet.
If the unit is placed below the drain level, the condensation pump
may be used with a collector tank and float to
evacuate the water: flow 2 l/min and 3 m lift.
ATTENTION: THE CONDENSATION DRAIN MUST BE POSITIONED FROST-FREE.