10
REVO SX
User’s manual
Technical Specifications
General features
Cover and Socket material:
PolymericV2
Mounting:
DIN bar (thickness type 1mm Max)
Utilization Category:
AC-51 AC-55b
IP Code:
20
Method of Connecting:
Single Phase load
Delay switch ON/OFF time:
1/2 Period Max
Input features
Logic input SSR:
4 ÷ 30Vdc 5mA Max (ON >4Vdc OFF <1Vdc)
Output features (power device)
Nominal current in continuous service: 4x3,5A - 3x4,5 - 2 x 7A
Max peak current (10ms):
350A
Nominal Voltage range
Ue
: 24÷480V
Repetitive peak reverse voltage
Uimp
: 1200V (480V)
Latching current:
250mA
Leakage current:
15mA eff
I²T value tp=10msec:
610 A²s
Frequency range:
47÷70Hz
Power loss (I=Inom):
4x4,2W - 3x5,4W - 2x8,4W
Isolation Voltage
Ui
: 2500Vac
Environmental installation conditions
Ambient temperature
0-40°C (32-104°F) at nominal current. Over 40°C use the derating
curve.
Storage temperature
-25°C to 70°C, -13°F to 158°F
Installation place
Don’t install at direct sun light, where there are conductive dust,
corrosive gas, vibration or water and also in salty environmental.
Altitude
Up to 1000 meter over sea level. For higher altitude reduce the
nominal current of 2% for each 100m over 1000m
Humidity
From 5 to 95% without condense and ice
Pollution Level
Up to 2nd Level ref. IEC 60947-1 6.1.3.2
Derating Curve
3
l max = l nominal x K
1
15 20 25 30 35 40 45 50 55
1,2
1
0,8
0,6
0,4
0,2
0
1
1
1
1
0,9
0,8
K
Derating
For higher cabinet
temperature
contact the producer
of the unit
CABINET TEMPERATURE °C