background image

Quick Start Guide 

Smart Relay – Low Voltage (SC824ZB) 

I

N THE 

B

OX

 

 

 

S

AFETY 

I

NSTRUCTIONS

 

 

 

Read these instructions carefully 

before installing and 

using

 the Smart Relay – Low Voltage and keep this guide 

in a safe place for future reference.  

 

Verify compatibility

 with your associated 

connected home system before installation. 

 

Follow all instructions provided by your connected 
home manufacturer regarding the addition of 
devices to your connected home system. An 
authorized, qualified installer may be required. 

 

Follow all applicable codes and regulations in the 
municipality where this product is installed. 

Salus accepts no responsibility for damage caused by not 
following these instructions. 

Smart Relay - Low Voltage 

Quick Start Guide 

 

N

OTE

Additional equipment may be required to address 
radio communication issues due to building 
construction or materials, or other radio interference. 

 

I

NSTALLATION 

I

NSTRUCTIONS

W

ALL 

B

OX 

M

OUNTING

 

 

Remove the assembly from the carton. 

 

Remove the front cover by lifting from the bottom. 

 

Position the relay in the desired location.  

If anchors are required: 

 

Mark the locations of the screws. 

 

Drill 3/16” holes. 

 

Insert the anchors (provided) 

 

Position the relay over the anchors. 

 

Secure with 2 mounting screws (provided). 

 

Wire relay as desired. See options below. Remove 
knockout on bottom side panel if required. 

 

Secure cables with the strain relief. 

 

Replace the front cover. 

S

URFACE 

M

OUNTING

 

 

Remove the assembly from the carton. 

 

Remove the front cover by lifting from the bottom. 

 

Remove the Relay Retainer by lifting the corners. 

 

Wire relay as desired. See options below. 

 

Remove white/blank backing from adhesive 
(provided). 

 

Apply adhesive to bottom half of relay back. 

 

Remove red lettered backing from adhesive. 

 

Press back of relay onto the surface to be attached. 

 

W

IRING 

O

PTIONS

D

RY 

C

ONTACT 

C

ONNECTIONS

:

 

 

 

 

Power In to terminal R 

 

Power Return to terminal C 

 

Load Out to terminal OUT 

 

Load Common to terminal COM 

P

OWER 

S

WITCH 

C

ONNECTIONS

:

 

 

 

 

Power In to terminal R 

 

Power Return to terminal C 

 

Load Out to terminal OUT 

 

Load Common to the open terminal C 

 

Add a wire between the open terminal R and COM 

OUT   COM     R        R         C         C 

18-30 VAC

LOAD OUT

LOAD COMMON

POWER IN

POWER RETURN

OUT   COM     R        R         C         C 

18-30 VAC

LOAD OUT

LOAD COMMON

POWER IN

POWER RETURN