Page 66
DC Voltage Measuring
a. Connect the black test lead to the “COM ” jack and the red test lead to the “V/
Ω
” jack.
b.Select
U
, enter the DC voltage measurement.
c. the tester default Auto range status ,by click “DC auto range” , press the
key can select manual range and restore auto range .
Manual range: 0.000V
à
6.600V range
00.00V
à
66.00V range
000.0V
à
660.0V range
000.0mV
à
660.0mV rang
AC Voltage Measuring
a. Connect the black test lead to the “COM” jack and the red test lead to the “V/
Ω
” jack.
b. select U ~ , enter the AC voltage measurement.
C.the tester default Auto range status, by click “AC auto range”
d. Manual range can be select , press the key “NEAR” to restore Auto range
e
.
Manual range: 0.000V
à
6.600V range
00.00V
à
66.00V range
000.0V
à
660.0V range
000.0mV
à
660.0mV range
DC Current Measuring (only manual range )
WARNING!
Shut down the power of the tested circuit, and then connect the meter with the circuit for measurement.
a. Connect the black test lead to the “COM ” jack and the red test lead to the “mA” jack for a maximum
of 660mA current. For a maximum of 10A, move the red lead to the 10A jack.
b
.
select
A
,
enter the DC current measurement,the screen display“DC current ”,can select manual
range
;
c
.
Manual range: 0.000mA
à
6.6mA range
00.00mA
à
66.00mA range
Summary of Contents for MON-4HD