background image

22

1

2

Connecting

Insert the connector 

to the Light Unit all 

the way in.

Removing

Press the lock 

and pull out the 

connector.

Connecting

Press the 

connector in until 

it locks in place.

Removing

Release the lock 

and remove the 

connector.

1

1

2

Displays the setting of the light intensity 

or the setting of the lighting mode.

Selects manual (MANU) or 

external (EXT) control mode.

Digital Window

BRT lit:    The light intensity can be set.

PLS lit:    The lighting mode can be set.

LOCK lit: The settings are locked.

Setting Indicators

Press: Switches between the light intensity  

setting and lighting mode setting.

Press for at least 2 seconds:

Locks the settings.

Rotate: Sets the light intensity or lighting mode.

Setting Switch

Selects L1, L2, or L3.

Channel Selection Switch

Used for external control with 

Ethernet communications.

External Control Connector

Pressed with a pointed object to reset 

all settings to their default values.

External Control Reset Switch

Inputs the ON/OFF signal for ON/OFF Mode.

Inputs the trigger signal for Strobe Mode.

External Trigger Input Connector

L1 lit:

Lit when changing settings for Light Unit 

connected to output connector L1.

L2 lit:

Lit when changing settings for Light Unit 

connected to output connector L2.

L3 lit:

Lit when changing settings for Light Unit 

connected to output connector L3.

Channel Indicators

Manual/External Mode Selector

Selects the logic of the trigger signal.

Trigger Logic Switch

Supply power to the Light Units.

Output Connectors

Connects the power source to the 

Control Unit.

AC Inlet

1

Removing the Rubber Feet from the 

Bottom of the Unit

2

Securing the Brackets to the Base 

of the Unit

3

Securing the Unit with Mounting Screws

Mounting to DIN Rail

Removing from DIN Rail

Before connecting the Control Unit, make sure that the main power source is turned OFF.
Making connections with the power turned ON may result in a fire or electric shock.

WARNING

Mounting the Unit to DIN Rail

Securing the Unit with Base Brackets

 (Optional, Sold Separately)

*An optional External Trigger Input Cable 

 (EXCB2-M10-3) (sold separately) is available.

1

2

3

4

Mounting

Removing

Output Connectors (L1 to L3)

External Trigger Input Connector (TRIG IN)

Always use Base Brackets (model: BK-PD3) when securing the Unit at its base.

If it is secured without the Brackets, the Unit may be damaged.

Connecting

Firmly insert the 

connector of 

the LAN cable.

1

2

Removing

Press the lock 

and pull out the 

connector.

*The LAN cable must be provided by the customer.

External Control Connector (EXTERNAL)

AC Inlet

Connect the power cord to the Control Unit 

and the AC outlet. The Control Unit will turn 

ON when power is supplied from the main 

power source. When the Unit is ON, the 

digital window will light.

Hook the tab on the upper part of the Unit 

on the DIN rail and press the Unit in the 

direction indicated by arrow 2 while pressing 

it in the direction indicated by arrow 1.

Press the Unit down in the direction 

indicated by arrow 3 and pull it out in the 

direction indicated by arrow 4.

Remove the screws that hold the rubber 

feet in place using a Phillips screwdriver.

Secure the Brackets to the base of the 

Unit with the four screws that come with 

the Brackets.

Secure the Unit in place with mounting screws.

The mounting screws must be provided by the 

user.

* The AC cord that is included with the Unit is for 

100 to 120 VAC. We recommend using the 

following for 200 to 240 VAC.

Cable: GTCE-3 x 1.0 mm

2

 (manufactured by 

Kawasaki Electric Wire Company), 

Connector: KS-31AY (manufactured by Kawasaki 

Electric Wire Company)

This product recognizes either cross-cable or 

straight-cable automatically by auto-negotiation 

function. Please reboot the product when 

changing the cable. 

Rubber foot

Installation screw holes

M3 screws for 

the rubber feet

(Insert the screws to a depth of no 

more than 5 mm and use a tightening 

torque of 0.3 N·m max.)

Screws for securing the Brackets 

to the mounting surface

(Prepare the mounting screws yourself 

according to the installation conditions.)

M3 screws for mounting the Brackets

(M3, included with the Brackets)

Holes for the mounting screws

(4.5 dia.)

In case using a self-made cable, cable length should 

be within 3 m at maximum.

(Cable length should be within 30 m at maximum.)

2

Names and Functions of Parts

3

Installation

4

Connections