22
1
2
Connecting
Insert the connector
to the Light Unit all
the way in.
Removing
Press the lock
and pull out the
connector.
Connecting
Press the
connector in until
it locks in place.
Removing
Release the lock
and remove the
connector.
1
1
2
Displays the setting of the light intensity
or the setting of the lighting mode.
Selects manual (MANU) or
external (EXT) control mode.
Digital Window
BRT lit: The light intensity can be set.
PLS lit: The lighting mode can be set.
LOCK lit: The settings are locked.
Setting Indicators
Press: Switches between the light intensity
setting and lighting mode setting.
Press for at least 2 seconds:
Locks the settings.
Rotate: Sets the light intensity or lighting mode.
Setting Switch
Selects L1, L2, or L3.
Channel Selection Switch
Used for external control with
Ethernet communications.
External Control Connector
Pressed with a pointed object to reset
all settings to their default values.
External Control Reset Switch
Inputs the ON/OFF signal for ON/OFF Mode.
Inputs the trigger signal for Strobe Mode.
External Trigger Input Connector
L1 lit:
Lit when changing settings for Light Unit
connected to output connector L1.
L2 lit:
Lit when changing settings for Light Unit
connected to output connector L2.
L3 lit:
Lit when changing settings for Light Unit
connected to output connector L3.
Channel Indicators
Manual/External Mode Selector
Selects the logic of the trigger signal.
Trigger Logic Switch
Supply power to the Light Units.
Output Connectors
Connects the power source to the
Control Unit.
AC Inlet
1
Removing the Rubber Feet from the
Bottom of the Unit
2
Securing the Brackets to the Base
of the Unit
3
Securing the Unit with Mounting Screws
Mounting to DIN Rail
Removing from DIN Rail
Before connecting the Control Unit, make sure that the main power source is turned OFF.
Making connections with the power turned ON may result in a fire or electric shock.
WARNING
Mounting the Unit to DIN Rail
Securing the Unit with Base Brackets
(Optional, Sold Separately)
*An optional External Trigger Input Cable
(EXCB2-M10-3) (sold separately) is available.
1
2
3
4
Mounting
Removing
Output Connectors (L1 to L3)
External Trigger Input Connector (TRIG IN)
Always use Base Brackets (model: BK-PD3) when securing the Unit at its base.
If it is secured without the Brackets, the Unit may be damaged.
Connecting
Firmly insert the
connector of
the LAN cable.
1
2
Removing
Press the lock
and pull out the
connector.
*The LAN cable must be provided by the customer.
External Control Connector (EXTERNAL)
AC Inlet
Connect the power cord to the Control Unit
and the AC outlet. The Control Unit will turn
ON when power is supplied from the main
power source. When the Unit is ON, the
digital window will light.
Hook the tab on the upper part of the Unit
on the DIN rail and press the Unit in the
direction indicated by arrow 2 while pressing
it in the direction indicated by arrow 1.
Press the Unit down in the direction
indicated by arrow 3 and pull it out in the
direction indicated by arrow 4.
Remove the screws that hold the rubber
feet in place using a Phillips screwdriver.
Secure the Brackets to the base of the
Unit with the four screws that come with
the Brackets.
Secure the Unit in place with mounting screws.
The mounting screws must be provided by the
user.
* The AC cord that is included with the Unit is for
100 to 120 VAC. We recommend using the
following for 200 to 240 VAC.
Cable: GTCE-3 x 1.0 mm
2
(manufactured by
Kawasaki Electric Wire Company),
Connector: KS-31AY (manufactured by Kawasaki
Electric Wire Company)
This product recognizes either cross-cable or
straight-cable automatically by auto-negotiation
function. Please reboot the product when
changing the cable.
Rubber foot
Installation screw holes
M3 screws for
the rubber feet
(Insert the screws to a depth of no
more than 5 mm and use a tightening
torque of 0.3 N·m max.)
Screws for securing the Brackets
to the mounting surface
(Prepare the mounting screws yourself
according to the installation conditions.)
M3 screws for mounting the Brackets
(M3, included with the Brackets)
Holes for the mounting screws
(4.5 dia.)
In case using a self-made cable, cable length should
be within 3 m at maximum.
(Cable length should be within 30 m at maximum.)
2
Names and Functions of Parts
3
Installation
4
Connections