55

Error Output

9 7 5 3 1

10 8 6 4 2

Trigger Logic 

Switch

ON/OFF 

Mode

Input signal

HIGH

OFF

Light Units ON

Light Units ON for the set time.

LOW

ON

Light Units OFF

No change

HIGH

OFF

Light Units OFF

No change

LOW

HIGH

LOW

ON

Light Units ON

Light Units ON for the set time.

Photocoupler

Strobe Mode

External Trigger Input Connector Plug

Enlarged Cable Diagram

Pink

Red 1

Example: Pin No. 10, pink, red 1

Input Signal and Photocoupler

Connector Layout

No.

Wire color

Marks

Signal

1

Light Unit ON/OFF control input (L1)

2

Light Unit ON/OFF control input (L2)

3

Light Unit ON/OFF control input (L3)

4 to 9

- - -

- - -

Not used.

10

Orange
Orange

Gray

Pink

Black 1

Red 1

Black 1

Red 1

Cable (EXCB2-M10-3)

Trigger Input Sequence Diagram

If another trigger is input before the Light Unit turns OFF in Strobe Mode, the starting point of the reentered trigger is taken as the start time and the strobe light continues for the set time from that point.

ON/OFF Mode

Trigger Logic Switch Set to HIGH

The Light Units turn ON when the photocoupler is OFF, and OFF when 

the photocoupler is ON.

Strobe Mode

Trigger Logic Switch Set to HIGH

From the point where the photocoupler goes OFF, the Light Units are 

turned ON for the set time (40 µs to 40 ms).

Photocoupler OFF

Photocoupler ON

Light Unit status

Not lit.

Not lit.

Lit.

Lit.

Not lit.

Not lit.

10 µs max.

10 µs max.

Photocoupler OFF

Photocoupler ON

Light Unit status

Not lit.

Not lit.

Lit.

Lit.

Not lit.

Not lit.

10 µs max.

10 µs max.

Trigger Logic Switch Set to LOW

The Light Units turn ON when the photocoupler is ON, and OFF when 

the photocoupler is OFF.

Trigger Logic Switch Set to LOW

From the point where the photocoupler goes ON, the Light Units are 

turned ON for the set time (40 µs to 40 ms).

Photocoupler OFF

Photocoupler ON

Light Unit status

Not lit.

Not lit.

Not lit.

Not lit.

10 µs max.

10 µs min.

40 µs to 40 ms

Lit.

Lit.

Photocoupler OFF

Photocoupler ON

Light Unit status

Not lit.

Not lit.

Not lit.

Not lit.

10 µs max.

10 µs min.

40 µs to 40 ms

Lit.

Lit.

* The LED Light Unit will turn off by OFF signal sent by either 

trigger signal input

 or 

Ethernet communications

.

* The LED Light Unit will turn on by ON signal sent by either 

trigger signal input

 or 

Ethernet communications

.

The input signal from the external trigger input connector can be used to control 

the photocoupler inside the Unit to turn the LED Light Units ON and OFF or to 

control strobe timing.

The operation depends on the setting of the trigger logic switch.

Signal Specifications

Setting Procedures

External Trigger Signal Connection Example

1

2

3

10

()

With the external trigger input connector pins 1 to 3, select the channels (L1 

to L3) where you want to input an external trigger, and input the trigger.

Trigger signals are input from the external trigger input connector in ON/OFF 

Mode and Strobe Mode in both Manual Mode or External Mode.

ON/OFF Mode

The Light Units are turned ON or OFF according to the external trigger signal input.

Strobe Mode

The Light Units are turned ON for the set time after the external trigger ignal is input.

Light Unit ON/OFF 

control input

L1

COMMON

PD3 Control Unit

External Circuits

Light Unit ON/OFF 

control input

L2

Light Unit ON/OFF 

control input

L3

12kΩ

22kΩ

2

1

3

10

12kΩ

22kΩ

12kΩ

22kΩ

Transistor (NPN) 

open collector

Transistor (NPN) 

open collector

Transistor (NPN) 

open collector

24 VDC

Rated input voltage Maximum input voltage

24 VDC

26.4 VDC

14.4 VDC min./3 mA max. 5 VDC max./1 mA max.

10 µs max.

12 kΩ (per terminal)

ON voltage/ON current

OFF voltage/OFF current ON/OFF response time

Input impedance

Inputting an External Trigger

8

9

Troubleshooting

When detecting the error during external control, command will be received as 

acknowledgement for checking status (over current confirmation) command “C”.

If the consumption current of Light Units exceeds 107% higher than the 

rated current, the overcurrent protection operates and stops the output.

OCP will be displayed on the digital window. 

Please check the rated current of Light Units and connect the Light Units 

under the rated current of this control unit.

Please press Setting Switch for over a second to reset the OCP error.

(OCP error can be reset by rebooting.)

Setting Switch

Press over a second

* Immediately after the error, occurrence of an error will be noticed only one time by 

using UDP protocol. Notify data is the same as checking status (over current 

confirmation) command “C”.

For details, refer to 

7. Control with External Signals

.

* When operating trigger signal input and Ethernet communications at same time in ON/OFF mode.

When Trigger logic switch is at HIGH: if ether controls setting to OFF setting, Light unit will be turned OFF

When Trigger logic switch is at LOW: if ether controls setting to ON setting, Light unit will be turned ON