background image

 

                                                                             ENGLISH 

 

 


 

4.2 Mounting Accessories  
 
 
 
 
 
 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 

 

Installation 

Ceiling fixing with MZ.FX01

 

Wall fixing with MZ.FX02

 

Picture 02 

Picture 03 

Summary of Contents for MIZAR Series

Page 1: ...1 ENGLISH Installation Manual ...

Page 2: ...essories 8 4 3 Installation 9 5 Power connection 11 5 1 24VDC power connection 11 5 2 230V power connection 11 5 3 Optional cable connections 12 6 Switch on Switch off 12 7 Problem solving 13 8 Light source replacement 13 9 Product maintenance and cleaning 13 10 Repairs 13 11 Warranty 14 12 Product Disposal 14 13 Technical information 15 14 Symbols 15 15 Declaration of Compliance 16 Table of conte...

Page 3: ...ized aluminum casing End caps in nylon PA66 Front prismatic plexiglass PMMA Mid Power LED light source 50 energy savings and constant flow beam for 60 000 hours 24 Vdc or 110 230Vac via cable 10 ft 3m 4 model sizes from 12W to 48 W Overhead mounting bracket and wall mounting bracket available Product Description ...

Page 4: ...ended only provided it is in perfect conditions and the user is well acquainted with all safety instructions CCEA the manufacturer waives any responsibility in case of product tampering or improper use 2 1 Proper use of the product This lighting equipment is fit for being installed inside machine tools even in a wet environment 2 2 Product safety Electrical Risks The improper and incorrect use of ...

Page 5: ... must be adjusted so as to avoid having the light flow directed towards the eyes Danger caused by inappropriate spare parts Using inappropriate spare parts may cause bodily injuries and material damages Do not use spare parts that have not approved by the manufacturer Damage caused by the presence of laser beams Use of the TRACKALPHA LED lighting equipment is not allowed when a high power laser se...

Page 6: ...urer will null and void the warranty 2 3 Damage risk levels Dangers that in case of non compliance immediately causes serious injuries or even death Dangers that in case of non compliance could cause serious injury or even death Dangers that in case of non compliance could cause injury Danger that can cause material damage in case of non observance HAZARD ATTENTION WARNING NOTICE Risk levels ...

Page 7: ...The product code is found on the brand name label stuck on the product s backside Find out the product code printed on the brand name label and see if you find it on the table hereunder Compare the codes and see if you can identify the same model on the table hereunder The code printed on the brand name label shows the device s week and year of production Note Do not discard the product labeling w...

Page 8: ...ENGLISH 8 4 2 Mounting Accessories Installation Ceiling fixing with MZ FX01 Wall fixing with MZ FX02 Picture 02 Picture 03 ...

Page 9: ...stallation using MZ FX01 The fastener kit consists of No 2 pairs of chrome steel brackets for lamp plaphone fastening No 2 screws M5x10 with washers for mating brackets No 2 M5x10 screws with rollsfor fixingbrackets on the lamp Hook the two pairs of fastening brackets using the screw Picture 04 Then fasten the brackets to the four dice lamp Picture 5 6 Then attach the lamp to the dedicated structu...

Page 10: ...pling washers No 2 M5x10 screws with bracket fastening washers on the lamp Hook the two pairs of fastening brackets using the supplied screw Picture 08 Then fasten the brackets to the four dice lamp Picture 09 Then attach the lamp to the dedicated structure using suitable M5 screws chosen by the installer Picture 10 Then connect the lamp to the power supply Picture 07 Picture 10 Picture 08 Install...

Page 11: ...ts com 5 1 24VDC Power Connection Any material damage caused by wiring errors will damage the lamp Qualified personnel must carry out the electrical connections Polarities of the conductors have to be correctly matched Cable output on the back of the lamp Conductor Connection Black 1 24VDC Black 2 0VDC On request the possibility of exiting side cable opposite to the side of the switch Stay within ...

Page 12: ...green GND 110 230VAC Stay within the input voltage range for the lamp so you don t damage the LED driver AC DC 5 3 Wiring Accessories Cod N12710001040202 CONN M12 4P M for ø 6 8mm cable Current max 4A Conductors cross section max 0 75mm2 IP67 6 Switching On and Off The lamp is equipped with an independent on and off switch system The switch stops in the power phase conductor Plug in WARNING NOTICE...

Page 13: ...r in case the replacement of the PCB LED is needed for any defects not covered by the warranty 9 Product Maintenance and Cleaning Switch off the power supply before any installation maintenance or reparation procedures This product is maintenance free Lamp cleaning to be carried out only after it has been switched off and surfaces have cooled down Carefully rinse the lamp surface with a mild clean...

Page 14: ... manual Liquid leakages inside the lamp Failure to follow the safety precautions related to transport and shipping the product back for repair please make sure to have it shipped back in its original case Period of warranty The warranty period covers 24 months starting from the delivery date CCEA guarantees that the products have no manufacturing defects or malfunctioning 12 Product disposal EU Re...

Page 15: ... IEC classe III Degree of protection IP40 LED driver Integrated driver system Light color 5000K CRI 80 Operating Temperature 20 45 C For other values see the table on page 7 Technical Data and Symbols IP40 Power supply 100 120V 220 240V 50 50Hz Power 12 24 36 48W see lamp IEC classe I Degree of protection IP40 LED driver sistema IDS integrato Light color 5000K CRI 80 Operating Temperature 20 45 C ...

Page 16: ...rt 2 particular requirements part 4 Portable general purpose luminaries CEI EN 62031 LED modules for general lighting Safety specifications CEI EN 62384 DC or AC supplied electronic control gear for LED modules Performance requirements This is a standard product manufactured following a detailed production schedule ensuring that inspections and destructive tests were carried out for a safe functio...