INSTALLATION
Fig.1 - DIMENSIONS (mm):
Fig.2 - VERTICAL INSTALLATION
IMPORTANT:
> The installation of this device must be carried out by specialist technicians.
>
:
Caution, do not connect the battery charger
- when a generator set with non stabilised output voltage is employed
- with power mains voltage exceeding the rated value (230V
±10%)
> Do not carry out any maintenance when the battery charger is connected to the
230V
power supply net.
> In case of battery charger misuse, the guarantee becomes invalid and the manufacturer
declines all responsibility for damages to people and property.
>
or more
people
This appliance can be used by children aged 8 years
and
with reduced
physical, sensory or mental capabilities or lack of experience
knowledge
or
, only
provided they are being supervised or they have been i
ed
the
nstruct
concerning
use of
the appliance in a safe way and
understand the hazards involved. Children shall
that they
not play with the appliance.
10
EN
190
85
160
207
BATTERY CHARGER
- Install the battery charger in an appropriate housing,
dry and ventilated; maximum efficiency can be
obtained
hen the battery charger is installed in a
w
vertical position (see figure 2), keeping the front at a
minimum istance of 300 mm and the bottom and top
d
at a minimum distance of 100 mm from the housing
sides.
- Do not cover air intakes.
- T
o guarantee proper air exchange, installation of
two air intakes (one placed on the top and one on
the ottom, see figure 2) ensure a working
b
temperature inside the housing not exceeding
50°C.
- M
ake sure that the 230V
safety switch can be
easily reached.
- T
he connection to power supply mains shall be
made in accordance with national installation rules.
- B
efore disconnecting the battery charger from
230V
power supply, turn the safety switch off.
- I
nstallation requires the fixing of 4 pins that can be
easily placed on the 4 sides.
- T
he battery charger can be installed together with
CBE 12V and 230V distribution panels, using the
appropriate modular joints.
CABLES
- M
ains connection: use a 3x1.5mm² cable, type
H05 RN-F or equivalent.
- B
attery connection: use N07 V-K cables having
adequate
section (minimum
section
cross
cross
6mm²).
- F
cable fastenings
ix the cables with the relevant
devices supplied.
- Protect cables from any possible damage.
BATTERY
- Lead-acid batteries shall be positioned in a well
ventilated place.
- U
(6 cells)
se only 12V
rechargeable lead batteries
(capacity >40Ah).
WARNING:
>
with
Do not use
“not rechargeable" batteries.
> Exhausted batteries shall be disposed in
accordance with existing environmental
protection regulations.
Summary of Contents for ENERGY CB522-3