5.
Keyboard System Settings
The keyboard will enter System Setup mode when the user presses the <
SYS
> key
and enters a correct password (default password is 0000). Detailed operation will be
described in the following sections. Use the
▲
(RUNSEQ) and
▼
(SETSEQ) keys to
scroll through the setup options.
1.0 System Setting
Enter password [____]
5.1 Keyboard
ID
Assignment
This option allows the user to assign a new ID for this keyboard. Press the
◄
or
►
key to change the ID number. The default ID for the control keyboard is 240.
1.1 Set Keyboard ID
(240-254):240
NOTE:
No two control keyboards connected to the same RS-485 bus should
be given the same ID.
5.2
GANZ PTZ Camera Control
There are two kinds of PTZ camera control mode. The user can press the right and
left direction keys in this setup menu to choose the control method – direct camera
control bypassing the connected DVR or through the DVR.
1.2 Camera Control
a. Bypass DVR
NOTE:
“Bypass DVR” means that control command signals will be sent
directly to PTZ cameras. The user can simply enter the PTZ camera ID
directly and operate the camera.
1.2 Camera Control
b. Through DVR
NOTE:
“Through DVR” means that control command signals will be sent to
the DVR, and the DVR will transfer these commands to the PTZ camera to
execute the relevant operation. Generally, we do not recommend controlling
cameras through a DVR in order to avoid any interference that can occur during the
process.
Summary of Contents for Ganz ZCA-SC Series