Alarm signal 2  (-  -  -)  is  a  non  life  threatening 

alarm, like a flooding alarm:

Smoke alarm signal:             

--- --- ---

Heat alarm signal:                

--- --- ---

Flood alarm signal:               

-    -   -

CO alarm low level signal:    

-    -   -

CO alarm high level signal:  

--- --- ---

Please note that only the originating alarm’s LED 

will flash, so it can be identified. 

9.

 PAUSE/HUSH FUNCTION:

If the smoke alarms are to set into a false alarm 

by cooking, fireplace, etc. they can be paused for 

10 minutes by pressing the test button on the 

originating smoke alarm only (indicated by the 

flashing LED).

The reason of this is that it is necessary to locate 

the source of the alarm before using the hush 

function.  This is to make sure that it is not a life 

threatening situation. 

10.  

ADD EXTRA DEVICE:

All CAVIUS interconnected alarms within the 

can be added to the system as 

they run on the same frequency and use the same 

data protocol.This means that the wireless system 

can consist of a combination of smoke, heat, flood 

etc.
Place all alarms into ‘Learn Mode’ and repeat 

section 1.
Always test connection to all devices by repeating 

test function section 6 after adding devices.

11.

 

LOW BATTERY SIGNAL:

Your product has a 10Y battery life.

When the battery is starting its end of life, a short 

beep will sound out every 48 seconds for 30 days.

The alarm affected by the low battery will only 

beep, no other connected alarms will sound.

It is recommended to replace the smoke alarm 

after 10 years, or if the alarm has suffered any 

damage. The alarm is not active unless it is insert-

ed in the mounting base.

Always check the alarm after inserting in the 

mounting base (allow a few seconds before test-

ing).

12.

 

MAINTENANCE & TROUBLE SHOOTING:

• The smoke alarm should be vacuum cleaned 

once per quarter, to remove dust particles, and 

it can be wiped with a damp cloth. (Do not open 

the alarm).

• High humidity condensing which can be 

resolved by drying the smoke alarm.

If the smoke alarm does not work when the test 

button is pushed, the probable cause is a faulty 

battery. Check if the battery is worn out by push-

ing the test button

If the problem continues, please visit www.cavius.

com for any trouble shooting. 

13.

 

OTHER INFORMATION:

Do not paint the alarm.

Note the local country regulations regarding 

installation.
Disposal: please dispose properly at the end of 

life. This is electronic waste which should be re-

cycled.
Please note local regulations about information 

to your insurance company regarding installed 

smoke alarms. 
The CE mark affixed to this product confirms its 

compliance with the European Directives which 

apply to the product and, in particular, its compliance 

with  the  harmonized  specifications  of  standard 

EN 14604 relating to Construction Products 

Regulation 305/2011. 

All Rights reserved: CAVIUS Aps assumes no 

responsi bility for any errors, which may appear in 

this manual. Furthermore, CAVIUS Aps reserves 

the right to alter the hardware, software, and/or 

specifications detailed herein at any time without 

notice, and CAVIUS Aps does not make any com-

mitment to update the infor mation contained here-

in. All the trademarks listed herein are owned by 

their respective owners. Copy right © CAVIUS Aps.

Once the mounting base is installed, attach the 

alarm by twisting clockwise until it clicks. If the bat-

tery is either missing or inserted incorrectly, or the 

switch is in ‘Learn Mode’, the smoke alarm will not 

be able to click into the mounting base. 

6

TEST FUNCTION:

After installation, and at least once per quarter, 

test all of your alarms to ensure they are operating 

correctly and are within range of each other.

It is recommended to check visually every week if 

the LED flashes correctly (every 48sec.)

Press the test button on any alarm for at least 

10 seconds. This will send out a test signal 

from the alarm; all other connected alarms 

should receive the signal within a short time. 

The alarms will emit a short beep and the 

LED will flash every 8 seconds for 2 minutes

NOTE: Test function also allows to send a deplet-

ed RF signal to ensure an optimal operation in 

normal conditions.

When the test signal is sent out, the alarms will 

respond in two ways:

1. A single beep every 8 seconds indicates that the 

alarms are connected and functioning.

2. Three short beeps every 8 seconds indicates a 

smoke sensor fault. The alarm should be cleaned 

by running the vacuum (on a low setting) around 

the smoke alarm chamber and tested again.

If required this indication can be stopped early on 

each alarm by a short press of the test button. 

TIP: It is safe to cover the sound output hole with 

your  finger  during  the  testing  to  minimize  the 

sound level emitted. 

If the problem continues, please visit www.cavius.

com for any trouble shooting. 

7. 

NORMAL MODE:

In normal mode the LED will flash every 48 seconds 

to show correct operation.

8.

  

ALARM MODE:

When a concentration of smoke is detected, the 

smoke alarm will go into ‘Alarm Mode’. It will 

sound the alarm signal and the LED will flash. 

The smoke alarm will also transmit the alarm sig-

nal to the other connected alarms, which will also 

sound the alarm signal after a short delay.

The CAVIUS Wireless Family have two different 

alarm signals: 

Alarm signal 1  (---  ---  ---)  is  life  threatening 

alarms, like a smoke alarm. 

CLICK THE SMOKE 

ALARM FIRMLY INTO THE 

BASE TO LOCK

0333

19

Download DoP document: www.cavius.com

EN 14604:2005 + AC :2008

DoP no.: 2106-003

127462rev1

Developed by CAVIUS Aps Julsøvej 16, DK-8600  

Manufactured in P.R.C.

HEAT ALARM

SMART REMOTE

FLOOD ALARM

SMOKE ALARM

MAINS POWERED

SMOKE ALARM

Reviews: