10.

The smoke alarm may NOT be placed:

•  In dusty rooms.

•  At the top of high pointed ceilings, instead  

  place a minimum of 50cm to a maximum of  

  150cm from the appex.

•   Within 50cm of a wall.

•   In rooms where the temperature goes  

  o5º to 45ºC or above 90% relative  

  humidity non condensing.

•   In kitchens, garages, or too close to  

  fireplaces. In areas that get damp or where  

  gases may occur. 
Place the smoke alarm where it is reachable in 

order to test the battery and complete maintenance.

Summary of Contents for 2008-001

Page 1: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...

Page 2: ...NSTALLATION AND RETAIN FOR FUTURE USE CAVIUS Photoelectric Smoke Alarm Part Code 2008 003 10019 10020 10021 Model 2008 001 Recess Kit Part Code 11010 For large text option and maintenance guide visit cavius co nz resources cavius com au resources ...

Page 3: ...1 CHAMBER FILTER ALARM AUDIBLE ALERT TEST HUSH BUTTON ...

Page 4: ...es and bedrooms as a minimum Smoke alarms on each floor in hallways and stairways Smoke alarms in each room such as bed rooms and living rooms Additional alarms will increase the safety The NZ and Australian Fire Services recommend smoke alarms in every bedroom hallway and living area for early fire detection ...

Page 5: ...3 ...

Page 6: ...wall The smoke alarm should be a minimum 50cm from the wall with a minimum of one smoke alarm per floor and a maximum distance between smoke alarms of 10 metres CEILING CEILING WALL WALL 50cm MINIMUM 50cm FROM WALL MINIMUM 30cm AND MAXIMUM 50cm FROM CEILING 4 ...

Page 7: ...m MUM M 2 After mounting allow 5 seconds for the alarm to power up and then test the smoke alarm by pushing the test button which is the entire bottom of the alarm The alarm should produce a loud sound 5 ...

Page 8: ...W HOLES WITH A PEN Installation of smoke alarm Info The label on the product must not be removed due to important information Option 1 Standard base 1 Use the mounting base ring to mark the screw holes on the ceiling ...

Page 9: ...7 USE THE ENCLOSED SCREWS AND PLUGS FOR INSTALLATION CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE ...

Page 10: ...8 Option 2 Recess Kit 1 Place the Cover Ring on the area where you wish to install the smoke alarm trace around the inside of the ring HOLE SAW DRILL REQUIRED 44mm 48mm ...

Page 11: ...e there is no wiring or any electrical equipment behind the surface you are drilling your hole into INSERT RECESS KIT MOUNTING BASE INTO THE HOLE AND SECURE WITH SCREWS PLACE COVER RING AROUND THE RECESS KIT MOUNTING BASE CLICK THE SMOKE ALARM FIRMLY INTO THE BASE TO ACTIVATE ...

Page 12: ... 150cm from the appex Within 50cm of a wall In rooms where the temperature goes outside 5º to 45ºC or above 90 relative humidity non condensing In kitchens garages or too close to fireplaces In areas that get damp or where gases may occur Place the smoke alarm where it is reachable in order to test the battery and complete maintenance ...

Page 13: ...arm should be vacuum cleaned once per quarter and can be wiped with a slightly damp cloth do not open the alarm Test the smoke alarm once per month by pushing the test button The smoke alarm should produce a loud alarm tone 11 ...

Page 14: ...rms have a visual and acoustic signal In the passive state the LED will flash every 48 seconds to indicate normal function In alarming state the LED will flash and the alarm will emit a sweeping sound pattern designed to alert occupants ...

Page 15: ... unintentional or false alarms press and hold the hush button for 2 seconds which is the entire bottom of the alarm This will mute the alarm for 10 minutes after which time the alarm will automatically resume its normal function ...

Page 16: ... smoke alarm is a photoelectric smoke alarm Alarm signal Fire alarm activation is indicated by a series of repeated tones The minimum sound level is 85 dB at 3 metres Battery Powered by a non replaceable CR123A 3V 1600mAh with 10 year life included ...

Page 17: ...his stage it will continue for a minimum of 30 days Please replace smoke alarm You must change the smoke alarm after 10 years of use or if the smoke alarm has suffered any damage The smoke alarm is not active unless it is clicked into the mounting base Always test the smoke alarm after clicking into the mounting base allow 5 seconds before testing ...

Page 18: ...tered the smoke chamber these can be removed by vacuuming around the mesh chamber If the smoke alarm does not work when the test button is pushed please check our Trouble Shooting Guides at cavius co nz and cavius com au Disposal For product please dispose properly at end of life The alarm can be recycled at an electronic waste recycling centre ...

Page 19: ...ations regarding installation of mains powered smoke alarms in new buildings The CAVIUS smoke alarm is a photoelectric alarm designed to be installed into residential homes camper vans and caravans It is not recommended for boats Certified to Australian Standard AS3786 2014 17 ...

Page 20: ...borg cavius com info cavius com Manufactured in P R C Distributor information for New Zealand CAVIUS Nano Ltd 58a Poplar Lane Papamoa 3187 NZ www cavius co nz for Australia CAVIUS Australia 14 30 Octal Street Yatala QLD 4207 Australia www cavius com au 18 ...

Page 21: ...wever this may have occurred If this product has an acknowledged defect it must be returned to the national CAVIUS distributor at the purchasers cost with the proof of purchase If the product has become defective within the 10 year warranty CAVIUS APS Denmark will repair or replace the unit without charge and send back to the purchaser via the national distributor at the distributors cost The guar...

Page 22: ...nting Ceiling and Wall Mounting Main power supply Internal power source battery included Battery duration 10 years Interconnectable device Yes No Suitable for installation in mobile home Yes No Product overview 20 ...

Page 23: ...Connection to external auxiliary devices Yes No Radio link Yes No Individual alarm indicator Yes No Alarm silence facility 10min Yes No Radioactivity infrared technology Yes No 21 127479 rev1 ...

Page 24: ...PLEASE READ THIS USER GUIDE CAREFULLY PHOTOELECTRIC SMOKE ALARM THE WORLD S SMALLEST ...

Reviews: