EN-7
UP
Press the key once, LED Display in regular flash showing current set temperature.
Continue pressing to adjust set temperature, one press increase 1
℃
. Regular flash
quit after 5 seconds detecting no press and new set temperature saved. LED display
return to show actual temperature inside.
Down
Press the key once, LED Display in regular flash showing current set temperature.
Continue pressing to adjust set temperature, one press reduce 1
℃
. Regular flash quit
after 5 seconds detecting no press and new set temperature saved. LED display return
to show actual temperature inside.
Child Lock
(
Combination key
)
1
、
Lock
:
Press both keys at the same time for 3 seconds to lock.
2
、
Unlock
:
Press both keys at the same time for 3 seconds to unlock.
Fahrenheit/Celsius display interchange
Switch temperature display between Fahrenheit and Celsius by pressing the key.
Attention
1. The ex-factory temperature of this product is 12
℃
, and the corresponding
temperature range needs to be set according to the actual wine.
2. For both upper and lower zone, the cooling temperature could be set from
5-
22
℃
. And temperature of lower zone could only be set equal to or higher than
that of upper zone.
3. Alarm sound: when the system malfunction occurs and alarm sound, press any
key on the control panel to cancel the alarm sound.
4. Error code:
When the temperature sensor of upper zone failure occurs, error code displays:
E1 for open circuit; E2 for short circuit.
When the temperature sensor of Lower zone failure occurs, error code displays:
E5 for open circuit; E6 for short circuit.
When the defrost sensor failure occur, error code displays: E3 for open circuit;
E4 for short circuit.