2.1
General Installation Requirements
The installation of these units is very simple. There are no special unpacking
instructions, except that care should be taken to handle units gently. Fiber optic
links are sensitive electronics devices that should be handled with care. Like most
electronics, they are susceptible to ESD. Proper ESD techniques, such as wearing
a wrist grounding strap, should be observed at all times when handling a unit. The
units should not be dropped. No assembly is required.
Do not install the equipment near sources of excessive heat, such as furnace out-
lets or above heat producing units, such as large power supplies and tube-type
equipment. Observe temperature and relative humidity requirements specified in
Section 1.3, page 2.
2.2
Items Provided
The following is a list of items provided with each Model 2809 LDS CATV
Receiver:
2.3
Items Required
Qty.
Mfr.
P/N
Description
AR
Force, Inc.
2809R-SFXX
CATV
Linx
®
LDS CATV Rx, SM, 1310/1550 nm,
SC/APC Connector Standard, FC/APC
Optional
1 per
connector
Any
Any
Active Device Receptacle Caps for RF and
Optical Connectors
Qty.
Mfr.
P/N
Description
AR
Force, Inc.
2806T-SCXX
CATV
Linx
®
77 Ch. LDS CATV Tx, SM, 1310 nm,
SC/APC Connector Standard, FC/APC
Optional
1 per Rx
Force, Inc.
PS095-1
Power Supply for Receiver, +9 Volts DC, 500
mA, 2-Pin Power Connector
4 per unit
Any
Any
6-32 Panhead Mounting Screws with Lock
Washers and Nuts
AR
Any
Any
Straight Screwdriver
AR
Any
Any
9/125
µ
m Single-mode Fiber
Section 2 Installation
Instructions