8
RAC16
User Guide
9M02-9029-A001-EN
Rev. 4
Changing the Configuration
New Factory Supplied Configuration within a RAC16
If a new configuration has been supplied by the factory,
make sure you have recorded the original
ID code at step one
, then the new configuration can be programmed into your device at this
stage, the RAC16 display will confirm a successful download.
Step through to the READ VERSION step and confirm the loaded configuration matches the new
one supplied.
Be sure to then step through to step one and reprogram the ID code, then verify the new ID Code
by re-connecting the RAC16A as explained above. The ID Code will appear in the display.
Copying the Configuration from one Unit to Another
Connect a RAC16 to the unit containing the desired configuration and step through to READ
CONFIG, enter password
when prompted ‘
916
’
.
Disconnect from that unit and connect the RAC16 to the unit that will be re-programmed
(WARNING THIS IS NOT REVERSABLE), record the current ID code, then step through to WRITE
CONFIG and enter, the RAC should report SUCCESS. If necessary, step through to the ID CODE
section and re-enter the correct ID code.