RAC16 

User Guide 

9M02-9029-A001-EN 
Rev. 4 

  

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

RAC16 

Programmer 

User Guide 

 

9M02-9029-A001-EN 

Summary of Contents for RAC16

Page 1: ...1 RAC16 User Guide 9M02 9029 A001 EN Rev 4 RAC16 Programmer User Guide 9M02 9029 A001 EN ...

Page 2: ...2 RAC16 User Guide 9M02 9029 A001 EN Rev 4 Revision History VERSION DATE NOTES 3 5 2 2019 Updated Branding and expanded Configuration programming 4 7 19 2019 Clarified OCU timeout and added PW ...

Page 3: ...Programmer Figure 1 incorporates an LCD display and membrane keypad plus an electrical cable to connect to the OCU or MCU that is being programmed it can be used to read or change the ID Code frequency and address and change the OCU time out FIGURE 1 RAC16A PROGRAMMER ...

Page 4: ...16A MENU AND FUNCTIONS NOTE Only MCU options will be available when the programmer is connected to an MCU Likewise only OCU options will be available when the programmer is connected to an OCU Sequence items highlighted in Red on the left are not available ...

Page 5: ...ve plus Key connector The programmer has a six position five plus Key connector See Figure 3 FIGURE 3 THREE AND SIX POSITION CONNECTORS Locate the programming connector on the OCU or MCU and connect the plug from the programmer the plug is polarized and must be aligned as shown above FIGURE 4 RAC16 CONNECTED TO OCU FIGURE 5 RAC16 CONNECTED TO MCU ...

Page 6: ...esignate one of the 81 operating frequencies Each system in a facility should be assigned a different frequency Figure 6 lists the frequency for each code The last four characters in the six digit code are the address code Each system in a plant must have a separate ID Code Rules for Assigning ID Codes It is important to control the assignment of the unit ID Codes Cattron accepts no responsibility...

Page 7: ...rent value so it can be re programmed after the configuration has been changed Changing the ID Code Enter the new 6 digit ID Code for the unit to be programmed Verify the number on the LCD display If a mistake is made when entering the code the BKSP ESC key will reposition the cursor to allow corrections ACTION RAC16A DISPLAY Enter the new 6 digit ID Code for the device being programmed ID CODE 28...

Page 8: ...lied Be sure to then step through to step one and reprogram the ID code then verify the new ID Code by re connecting the RAC16A as explained above The ID Code will appear in the display Copying the Configuration from one Unit to Another Connect a RAC16 to the unit containing the desired configuration and step through to READ CONFIG enter password when prompted 916 Disconnect from that unit and con...

Page 9: ...ation is defined within the Configuration parameters above ACTION RAC16A DISPLAY Press the MENU button on the RAC16A until the display shows TX TIME OUT XX TX TIME OUT XX XX represents the current time out value in minutes of the connected OCU Enter the new value from 01 to 60 00 will not time out the OCU and require it to be shut off manually PROGRAM TX CONFIG PROGRAM RX CONFIG Press PRG button o...

Page 10: ...4 33 923 7 48 905 1 0A 911 4 1F 917 7 34 924 0 49 905 4 0B 911 7 20 918 0 35 924 3 4A 905 7 0C 912 0 21 918 3 36 924 6 4B 906 0 0D 912 3 22 918 6 37 924 9 4C 906 3 0E 912 6 23 918 9 38 925 2 4D 906 6 0F 912 9 24 919 2 39 925 5 4E 906 9 10 913 2 25 919 5 3A 925 8 4F 907 2 11 913 5 26 919 8 3B 926 1 50 907 5 12 913 8 27 920 1 3C 926 4 51 907 8 13 914 1 28 920 4 3D 926 7 52 908 1 14 914 4 29 920 7 3E...

Page 11: ...Stop is manufactured at the following location Cattron North America Inc 655 N River Rd NW Suite A Warren OH 44483 Cattron property and confidential 9M02 9029 A001 EN Rev 4 Due to continuous product improvement the information provided in this document is subject to change without notice Cattron Support For remote and communication control systems support parts and repair or technical support visi...