9.17
Digital Output Configuration – Type 13
Parameters for Digital Output Configuration
Parameter
Code
Reference Description
Default
1
Name
A representative name to reference the
channel by.
C
ASCII Text
30 characters max
2
Active
State
Define what state is considered the
active state. Used to track number of
activations and duration activated.
Channel
Specific
0 = open
1 = close
2-3 = do nothing
3
Source
Define the source of the value that
should drive this output
8
Range – valid data register
4
Pulse
Duration
Defines the duration that the output
will stay in the activated state.
1
0 – de-activate pull-up
1 – activate pull-up
5
Output
State
When
Source
Value is 1
Defines the state of the output when
the source data register value = 1
1
0 = open
1 = close
2-3 = do nothing
6
Output
State
When
Source
Value is 0
Defines the state of the output when
the source data register value = 0
1
0 = open
1 = close
2-3 = do nothing