background image

User Manual LRC-L1 

 

 

 

Version 1.0.0 - 11/2010 

Subject to change without notice. 

5

 

2 Safety Instructions 

2.1 Used Symbols and Definitions for Warnings 

!

 

Warning against hazardous situation 

 

Warning against electrical voltage 

!

 

Useful information 

 

DANGER 

Calls attention to a dangerous situation with high risk, severe injuries or death 
possible. 

 

WARNING 

Calls attention to a situation with medium risk, severe injuries possible. 

 

CAUTION 

Calls attention to a situation with low risk, injuries or damage to the device possible.

 

NOTE 

Calls attention to important information. 

2.2 General Information on Safety 

• 

Persons under the influence of drugs and/or alcohol and/or other medicine that impairs their reaction may 

not assemble, disassemble, install, put into operation, repair or operate the product. 

• 

All conversions and modifications of an installation/system must conform to the relevant safety 

requirements. Work on the electrical equipment must be performed only by qualified, authorized 
personnel and in accordance with the relevant safety requirements. 

• 

In the event of malfunctioning and visible defects or irregularities, the product must be stopped, switched off 

and the relevant master switches must be switched off. 
 

WARNING 

!

 

Observe the statutory regulations and directives applicable for the intended purpose, e.g.: 

• 

Accident prevention regulations 

• 

Safety rules and directives 

• 

Standards 

• 

Generally applicable statutory and other binding regulations for accident prevention and 
environmental protection and general safety and health requirements. 

 

• 

The user must instruct his personnel accordingly. 

• 

The Operating Manual must be kept permanently accessible at the place of use of the product. 

• 

The personnel assigned to work on/with the product must have read and understood this Operating Manual 

and the safety instructions. 

• 

The safety instructions must, if necessary, be supplemented by the user with instructions concerning the 

work organisation, work sequences, used personnel, etc.  

• 

Only trained personnel may perform the work (maintenance and repair) with/on the product. 

• 

It is the user’s responsibility to ensure that the product is always operated in a perfect condition and that all 

applicable safety requirements and regulations are being observed. 

• 

Product modifications may not be carried out without the consent of the manufacturer. 

• 

In any event, only original spare parts from the manufacturer must be used. 

• 

Periodical inspections and/or maintenance either required by law or prescribed in the user manual must be 

carried out within the required intervals 

Summary of Contents for LRC-L1

Page 1: ...User Manual Radio Remote Control LRC L1 Transmitter Unit ...

Page 2: ...6363 100 Internet www cattron theimeg de E Mail info theimeg de Copyright This technical document or parts thereof may not be reprinted or copied except for own use for the operation of the radio transmitter system without the written permission of Cattron Theimeg Europe GmbH Co KG It may not be made accessible to a third party The copying of the described radio remote control system is not permit...

Page 3: ...mmand 9 4 8 Automatic Turn off 10 4 9 Status LED 10 5 Battery Battery Charger 11 5 1 Connecting the Battery Charger 11 5 2 Charger Status Indication 11 5 3 Charging the Battery 12 5 4 Defective Battery 12 5 5 Battery Discharging 12 6 RF Channel Change 13 6 1 Working Principle 13 6 2 Activating the Programming Mode 13 6 3 Changing the RF Channel 13 6 4 Receiver Synchronisation to new RF Channel 14 ...

Page 4: ...tion of the radio remote control transmitter series CattronControl LRC L1 The information is of general nature and does not include system specific data System specific data is provided in the technical documentation accompanying the delivery of the system For Information pertaining to the matching receiver unit please refer to the separate user manual ...

Page 5: ...aster switches must be switched off WARNING Observe the statutory regulations and directives applicable for the intended purpose e g Accident prevention regulations Safety rules and directives Standards Generally applicable statutory and other binding regulations for accident prevention and environmental protection and general safety and health requirements The user must instruct his personnel acc...

Page 6: ...nstructions for Assembly Disassembly Assembly disassembly work may only be performed by qualified persons NOTE Please assure suitable interference protection element of triggered electrical relays or valves Regard in particular the wiring of the crane s main contactor and the manual radio switchover The system must be isolated from the electrical power in accordance with the applicable regulations...

Page 7: ...lid telegram for a certain period of time PNH Time it will automatically turn off i e safety relays and command relays open Depending on the application the PNH Time varies from 0 5 s to 2 0 s 3 1 2 Area of operation In order to ensure optimum communication between the transmitter and the receiver unit the transmitter should be operated ideally with line of sight to the receiver or its antenna at ...

Page 8: ...2 Display Option The transmitter can optionally be equipped with a graphic display This can be used to indicate certain transmitter parameters such as the operating frequency internal error messages battery status and or to display feedback data that is being transmitted back from the corresponding radio receiver which in this case functions as a transceiver receiving and transmitting data For fur...

Page 9: ...ON position I Status LED lights red Activate the Stop switch Status LED light orange and release within 10 seconds Status LED flashes green The transmitter is turned on NOTE After the transmitter has been turned on the safety relays in the receiver unit should be energized and the receiver should be able to respond to commands initiated by the transmitter 4 6 Turning the transmitter off Turn the t...

Page 10: ...n battery low Internal failure hardware or software 4 9 Status LED The status LED indicates the operation mode and error messages Status LED Condition Corrective Action Flashes green 2 0 sec interval Normal mode No action required Flashes red 2 0 sec interval Error indication Refer to section Trouble shooting Flashes red 0 5 sec interval Pre warning low voltage Change the battery within 10 minutes...

Page 11: ...r unit with cradle DANGER Electric shock Do not open the charger The charger must be protected against moisture and rain in order to exclude the fire hazard or an electric shock The charger must only be operated in dry indoor spaces Do not use the charger if the housing or mains plug is damaged Contact the customer service department of Cattron Theimeg Europe GmbH Co KG 5 2 Charger Status Indicati...

Page 12: ...tus of the battery is constantly monitored and automatically terminated when the charging process is completed Overcharging is therefore prevented NOTE The battery charging time can take up to 3 hours NOTE Batteries may only be charged at a maximum ambient temperature of 40 C 5 4 Defective Battery Before the charging process begins the battery is tested for defects If the green Ready LED lights up...

Page 13: ...ocated to the left and right of the STATUS LED Each RF channel has been assigned a specific colour code shown in the RF Channel Tables Figure 6 LED Push button panel 6 2 Activating the Programming Mode Before the RF channel can be changed the transmitter unit must be brought into Programming Mode With the transmitter unit turned off hold the horn push button down and turn the unit on by turning th...

Page 14: ...etermine whether other systems are transmitting on the currently selected RF channel The level of interference i e the field strengths of such systems can be indicated The interference field strength is displayed via the Status LED in combination with the internal acoustic buzzer signal In the event that there is interference on the selected RF channel it is recommended that a different free RF ch...

Page 15: ...ilable for the 869 MHz frequency band Bring the transmitter unit into programming mode see above If already in programming mode continue with the next step Press HORN push button for 5 Seconds until a sound is audible and release it RF Band scanning starts indicated by the STATUS LED changing from red to blinking orange RF channel LEDs are changing according to the RF channel Tables Once the scann...

Page 16: ... orange 3 419 0000 orange 4 419 0250 orange red 5 419 0500 orange green 6 419 0750 orange orange 7 419 1000 red 8 419 1250 red red 9 419 1500 red green 10 419 1750 red orange 11 419 2000 red red 12 419 2250 red red red 13 419 2500 red red green 419 2750 red red orange 6 8 2 RF Channel Table 447 MHz Band STATUS 1 2 1 2 STATUS 1 2 1 2 Channel Frequency MHz 1 2 3 4 1 447 8625 orange red 2 447 8750 or...

Page 17: ...d orange green 31 433 8275 red orange orange 32 433 8525 green 33 433 8775 green red 34 433 9025 green green 35 433 9275 green orange 36 433 9525 green red 37 433 9775 green red red 38 434 0025 green red green 39 434 0275 green red orange 40 434 0525 green green 41 434 0775 green green red 42 434 1025 green green green 43 434 1275 green green orange 44 434 1525 green orange 45 434 1775 green orang...

Page 18: ... 909 4 red orange 29 919 0 red orange red 30 920 2 red orange green 31 921 4 red orange orange 32 922 6 green 33 923 8 green red 34 903 6 green green 35 904 8 green orange 36 906 0 green red 37 907 2 green red red 38 908 4 green red green 39 909 6 green red orange 40 919 2 green green 41 920 4 green green red 42 921 6 green green green 43 922 8 green green orange 44 924 0 green orange 45 903 8 gre...

Page 19: ...iMH 4 8 V 1600 mAh Quick swap rechargeable battery 12 h 100 duty cycle Control elements variable Indication 1 Status LED for status and error indication 4 Multi LEDs for RF channel selection 1 Buzzer LCD Display optional Weight approximately 1 6 kg Dimensions W x H x D 320 x 255 x 185 mm Housing Plastic standard colours red grey Operating temperature 20 ºC 60 ºC Protection class IP 65 STOP command...

Page 20: ...e read Plug in TransKey 3 Error detected in TransKey configuration Have the TransKey configuration checked by Cattron Theimeg 4 Low voltage condition of the mains supply detected Change main board 5 Switch on sequence not carried out correctly Switch the transmitter off and on again following the correct switch on sequence 6 Fault during reading control elements Replace control element or main boa...

Page 21: ...User Manual LRC L1 Version 1 0 0 11 2010 Subject to change without notice 21 9 Appendices Declaration of Conformity Declaration of Manufacturer Manufacturer ISO Certificate ...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ...User Manual LRC L1 22 Subject to change without notice Version 1 0 0 11 2010 ...

Reviews: