E
Gas grill MANHATTAN
instructions for use
Please read these operating instructions thoroughly before use and save them for future reference.
-02-
IGNITION:
ź
all b
urner
s
uses
s
ingle shot piezo ignition unit
IMPORTANT
ź
Read the following instructions carefully and be sure your barbecue is properly installed, assembled and cared for. Failure to
follow these instructions may result in serious body injury and/or property damage.
ź
If you have any questions concerning assembly or operation, consult your dealer or LPG Gas Company.
ź
A
lways place the appliance and
gas bottle
on level
ed flat
ground.
ź
Never light the appliance with the HOOD in the closed position.
ź
Your barbecue can be used
with
gas
bottles
between 11 kg
to
15 kg. Your barbecue will perform better if propane or LPG
mixtures are used. Butane can be used
also,
but because of the rate of
gas flow,
the
bottle
tend to freeze
so
the gas is then
suppl
ied
at reduced pressures
, thus
affecting the performance of your barbecue.
When s
e
t
t
ing the barbecue the following clearances must be obeyed:
ź
Sides and rear of appliance: 1 metre from any obstruction.
ź
Above the appliance: NO OVERHEAD OBSTRUCTION ARE PERMITTED.
NOTE FOR CONSUMER:
Retain
this manual
for future Reference
CONNECTING THE GAS CYLINDER TO THE APPLIANCE
ź
This appliance is only suitable for use with low-pressure butane or propane gas or LPG mixtures, fitted with the appropriate low-
pressure regulator via a flexible hose. The hose should be secured to the regulator and the appliance. This barbecue is set to
operate
with
30 mbar regulator with LPG gas. Use a suitable regulator certified
of
BSEN 16129. Please consult your LPG dealer
for information
s
regarding a suitable regulator for the gas
bottles
.
R
EGULATOR AND HOSE
ź
These items are supplied with barbecue, but replacements are available from your equipment retailer or an authorised LPG gas
stocket. Use only regulators and hose approved for LP Gas at the above pressures. The life expectancy of the regulator is
estimated as 10 years. It is recommended that the regulator should be changed within 10 years of the date of manufacture.
ź
The use of the wrong regulator or hose is dangerous, always check that you have the correct items before operating the
barbecue.
ź
The hose used must conform to the relevant standards for the country of use. The length of the hose must be 1.5 metres
(maximum). Worn or damaged hose must be replaced. Ensure that the hose is not obstructed, kinked or in contact with any part
of the barbecue other than at its connection.
STORAGE OF APPLIANCE
ź
The appliance should be only allowed to store indoors when appliance is disconnected and removed from the cylinder. When
the appliance is not in use for a period of time it should be stored in its original packaging and stored in a dry, dust free
environment.
GAS CYLINDER
ź
The gas
bottle
should not be dropped or handled roughly. If the appliance is not in use, the
bottle
must be disconnected.
Replace the protective cap on the cylinder after disconnecting the cylinder from the appliance.
ź
Cylinders must be stored outdoors in an upright position and out of the reach of children. The cylinder must never be stored
where temperatures can reach over 50o C. Do not store the cylinder near flames, pilot lights or other sources of ignition. DO
NOT SMOKE NEAR THE CYLINDER(S).
ź
This barbecue is designed for outdoor
use
only, away from any flammable materials. It is important that there are no overhead
obstructions and that there is a minimum distance of 1m from the side and rear of the appliance. It is important that the
ventilation openings of the appliance are not obstructed. The barbecue must be used on a level, stable surface. The appliance
should be protected from direct draughts and should be positioned or protected against direct penetration by any trickling water
(e.g. rain).
ź
Parts sealed by the manufacturer or his agent must not be altered by the user. No modifications should be made to any
part of this barbecue and repairs and maintenance should only be carried out by a CORGI registered service engineer.
TECHNICAL INFORMATIONS:
Manufacturer:
Jiang Men City Hong Hua Metal Prodcuts Co., Limited
Type:
G9206A-SB (99BB006)
Total heat inpout (all gas categories):
18.2kW (1326 g/h)
Gas category:
I3+(28-30/37)
I3B/P(30)
Gas type:
Butan
Propane
LPG (mixture of gas)
Gas pressure:
28-30 mbar
37 mbar
30 mbar
Nozzle size:
main: 0,75 mm
main: 0,75 mm
side: 0,85 mm
side: 0,85 mm
Identification code:
0359CL1116
Summary of Contents for MANHATAN
Page 14: ...14 31 1 2 4 6 5 3 8 9 10 7 11 12 13 14 15 16 19 20 21 22 24 25 27 28 29 30 18 23 26 17...
Page 15: ...15 20 1 2 16PCS 4PCS 21 9 8 A A A A A A A A A A A A A M6X10 A M6X10...
Page 16: ...16 3 4 Mut 2 PCS 2 PCS E M3 D M3X10 4PCS E D A A A A A M6X10...
Page 17: ...17 6 5 8PCS 4PCS A A A A A A A M6X10 A M6X10...
Page 18: ...18 8 7 8PCS A A A A A M6X10...
Page 19: ...M6X10 4Pcs A 9 10 19...
Page 20: ...12 11 C C M4X10 2Pcs C 20...
Page 21: ...14 13 C M4X10 2Pcs C C C C M4X10 2Pcs C 21...
Page 22: ...15 B B Clip 2Pcs 22...
Page 23: ...23...